National Dam Safety Program. Parker Dam (NDI Number PA 01126, PennDER Number 17-87), Susquehanna River Basin, Laurel Run, Clearfield County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Parker Dam (NDI Number PA 01126, PennDER Number 17-87), Susquehanna River Basin, Laurel Run, Clearfield County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 71 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Parker Dam (NDI Number PA 01126, PennDER Number 17-87), Susquehanna River Basin, Laurel Run, Clearfield County, Pennsylvania. Phase I Inspection Report by : John A. Dziubek

Download or read book National Dam Safety Program. Parker Dam (NDI Number PA 01126, PennDER Number 17-87), Susquehanna River Basin, Laurel Run, Clearfield County, Pennsylvania. Phase I Inspection Report written by John A. Dziubek and published by . This book was released on 1980 with total page 71 pages. Available in PDF, EPUB and Kindle. Book excerpt: Parker Dam is classified as a 'Significant' hazard - 'Small' size dam. The dam and reservoir, owned by the Commonwealth of Pennsylvania, Department of Environmental Resources, are used for recreational purposes. The dam and appurtenant structures were found to be in good overall condition at the time of the inspection. A spillway design flood (SDF) in the range of the 100-year flood to the 1/2 Probable Maximum Flood (1/2 PMF) is required for Parker Dam. Since the dam is in the middle of the 'Small' size category according to storage capacity, the 1/2 PMF was selected as the SDF. Hydrologic/hydraulic evaluations, performed in accordance with procedures established by the Baltimore District of the U.S. Army Corps of Engineers, revealed that the available spillway capacity is much greater than the maximum flow expected during the SDF. Therefore, the dam will not be overtopped during the SDF and the spillways are considered to be 'adequate'.

Technical Abstract Bulletin

Download Technical Abstract Bulletin PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 228 pages
Book Rating : 4.E/5 ( download)

DOWNLOAD NOW!


Book Synopsis Technical Abstract Bulletin by :

Download or read book Technical Abstract Bulletin written by and published by . This book was released on 1981 with total page 228 pages. Available in PDF, EPUB and Kindle. Book excerpt:

National Dam Safety Program. Penn Nursery Dam (NDI I.D. Number PA-00470, Penn DER I.D. Number 14-117), Susquehanna River Basin, Potter Run, Centre County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Penn Nursery Dam (NDI I.D. Number PA-00470, Penn DER I.D. Number 14-117), Susquehanna River Basin, Potter Run, Centre County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 82 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Penn Nursery Dam (NDI I.D. Number PA-00470, Penn DER I.D. Number 14-117), Susquehanna River Basin, Potter Run, Centre County, Pennsylvania. Phase I Inspection Report by : Bernard M. Mihalcin

Download or read book National Dam Safety Program. Penn Nursery Dam (NDI I.D. Number PA-00470, Penn DER I.D. Number 14-117), Susquehanna River Basin, Potter Run, Centre County, Pennsylvania. Phase I Inspection Report written by Bernard M. Mihalcin and published by . This book was released on 1980 with total page 82 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a visual inspection, operational history, and available engineering data, the dam is considered to be in good condition. The size classification of the facility is small and its hazard classification is considered to be high. In accordance with the recommended guidelines, the Spillway Design Flood (SDF) for the facility ranges between the 1/2 PMF (Probable Maximum Flood) and the PMF. Due to the high potential for damage to downstream structures and possibly loss of life, the SDF is considered to be the PMF. Results of the hydrologic and hydraulic analysis indicate the facility will pass and/or store approximately 92 percent of the PMF prior to embankment overtopping. Based on screening criteria contained in the recommended guidelines, the spillway is considered to be inadequate, but not seriously inadequate. Deficiencies noted by the inspection team included a seepage condition along a portion of the downstream embankment toe approximately 160 feet to the right of the left abutment hillside and a minor vertical crack in the concrete spillway overflow wall.

Government Reports Annual Index

Download Government Reports Annual Index PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 986 pages
Book Rating : 4.:/5 (3 download)

DOWNLOAD NOW!


Book Synopsis Government Reports Annual Index by :

Download or read book Government Reports Annual Index written by and published by . This book was released on 1981 with total page 986 pages. Available in PDF, EPUB and Kindle. Book excerpt:

National Dam Safety Program. Poe Dam (NDI I.D. Number PA-00471, Penn Der I.D. Number 14-105), Susquehanna River Basin, Big Poe Creek, Centre County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Poe Dam (NDI I.D. Number PA-00471, Penn Der I.D. Number 14-105), Susquehanna River Basin, Big Poe Creek, Centre County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 79 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Poe Dam (NDI I.D. Number PA-00471, Penn Der I.D. Number 14-105), Susquehanna River Basin, Big Poe Creek, Centre County, Pennsylvania. Phase I Inspection Report by : Bernard M. Mihalcin

Download or read book National Dam Safety Program. Poe Dam (NDI I.D. Number PA-00471, Penn Der I.D. Number 14-105), Susquehanna River Basin, Big Poe Creek, Centre County, Pennsylvania. Phase I Inspection Report written by Bernard M. Mihalcin and published by . This book was released on 1980 with total page 79 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a visual inspection, operational history, and available engineering data, the dam is considered to be in good condition. The size classification is considered to be high. In accordance with recommended guidelines, the Spillway Design Flood (SDF) for this facility ranges between the 1/2 PMF (Probable Maximum Flood) and the PMF. Due to the high potential for damage to downstream structures and possibly loss of life, the SDF is considered to be the PMF. Results of the hydrologic and hydraulic analysis is indicate the facility will pass and/or store approximately 75 percent of the PMF prior to embankment overtopping. As a result, the spillway is deemed inadequate, but not seriously inadequate.

National Dam Safety Program. Ward Run. NDI Number PA-01124 PennDER Number 63-75 SCS Number PA-483. Ohio River Basin, Washington County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Ward Run. NDI Number PA-01124 PennDER Number 63-75 SCS Number PA-483. Ohio River Basin, Washington County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 87 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Ward Run. NDI Number PA-01124 PennDER Number 63-75 SCS Number PA-483. Ohio River Basin, Washington County, Pennsylvania. Phase I Inspection Report by : John A. Dziubek

Download or read book National Dam Safety Program. Ward Run. NDI Number PA-01124 PennDER Number 63-75 SCS Number PA-483. Ohio River Basin, Washington County, Pennsylvania. Phase I Inspection Report written by John A. Dziubek and published by . This book was released on 1980 with total page 87 pages. Available in PDF, EPUB and Kindle. Book excerpt: PA 483 is a 74-foot high, zoned-earthfill floodwater retarding dam designed by the U.S. Department of Agriculture, Soil Conservation Service (SCS). The dam is owned and operated by the Washington County Commissioners. The dam consists of a 360 foot long embankment, a vegetated earth side channel emergency spillway, and an intake riser and outlet conduit (principal spillway). The dam and appurtenant structures were found to be in good overall condition at the time of the inspection. Hydraulic/hydrologic evaluations revealed that the spillway will pass the Probable Maximum Flood (PMF) without overtopping the dam. PA 483 is a 'High' hazard, 'Intermediate' size dam requiring evaluation for a spillway design flood (SDF) equal to the PMF. Therefore, the spillway is assessed as 'adequate.' The inspection revealed certain items of remedial work which should be performed immediately by the owner.

National Dam Safety Program. Unnamed Tributary to Harmon Creek, NDI Number PA-01123 PennDER Number 63-81. SCS Number PA-485. Ohio River Basin. Washington County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Unnamed Tributary to Harmon Creek, NDI Number PA-01123 PennDER Number 63-81. SCS Number PA-485. Ohio River Basin. Washington County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 96 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Unnamed Tributary to Harmon Creek, NDI Number PA-01123 PennDER Number 63-81. SCS Number PA-485. Ohio River Basin. Washington County, Pennsylvania. Phase I Inspection Report by : John A. Dziubek

Download or read book National Dam Safety Program. Unnamed Tributary to Harmon Creek, NDI Number PA-01123 PennDER Number 63-81. SCS Number PA-485. Ohio River Basin. Washington County, Pennsylvania. Phase I Inspection Report written by John A. Dziubek and published by . This book was released on 1980 with total page 96 pages. Available in PDF, EPUB and Kindle. Book excerpt: PA 485 is a zoned earthfill embankment with a total length of 630 feet, including the emergency spillway on the left abutment. The height and crest width of the embankment are 78 feet and 14 feet, respectively. The embankment was constructed using three zones of fill material. The principal spillway is a drop-inlet structure consisting of a two stage reinforced concrete riser connected to a 30 inch diameter reinforced concrete outlet pipe. The emergency spillway for the dam is located at the left abutment. It consists of a vegetated trapezoidal channel with a bottom width of 50 feet and 2H:1V side slopes. Hydrologic/hydraulic evaluations revealed that the spillway will pass the Probable Maximum Flood (PMF) without overtopping the dam. A spillway design flood (SDF) equal to the PMF is required for PA 485. The spillway is therefore considered to be 'adequate'. The visual inspection revealed several minor deficiencies which require remedial action by the owners of the dam.

National Dam Safety Program. Upper and Lower Dams (NDI Number PA 00389, PennDER Number 20-55, SCS Numbers PA 487A and B), Ohio River Basin, Crooked Creek, Crawford County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Upper and Lower Dams (NDI Number PA 00389, PennDER Number 20-55, SCS Numbers PA 487A and B), Ohio River Basin, Crooked Creek, Crawford County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 132 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Upper and Lower Dams (NDI Number PA 00389, PennDER Number 20-55, SCS Numbers PA 487A and B), Ohio River Basin, Crooked Creek, Crawford County, Pennsylvania. Phase I Inspection Report by : BAKER (MICHAEL) JR INC BEAVER PA.

Download or read book National Dam Safety Program. Upper and Lower Dams (NDI Number PA 00389, PennDER Number 20-55, SCS Numbers PA 487A and B), Ohio River Basin, Crooked Creek, Crawford County, Pennsylvania. Phase I Inspection Report written by BAKER (MICHAEL) JR INC BEAVER PA. and published by . This book was released on 1980 with total page 132 pages. Available in PDF, EPUB and Kindle. Book excerpt: Upper and Lower Dams consist of two dams in series designed by the U.S. Department of Agriculture, Soil Conservation Service (SCS) for floodwater detention and waterfowl habitat enhancement. Lower Dam is the primary structure upon which this report focuses because the majority of Upper Dam becomes inundated by backwater from Lower Dam before the emergency spillways at Lower Dam are activated. Hydraulic/hydrologic evaluations revealed that the spillways will pass the Probable Maximum Flood (PMF) without overtopping Lower Dam. A spillway design flood (SDF) equal to the PMF is required for Lower Dam. Therefore, the spillways are considered 'adequate.' The inspection revealed only one deficiency which should be corrected immediately, namely, the repair of the chipped concrete on the impact basin of Upper Dam.

National Dam Safety Program. Treated Water Pond (NDI Number PA 01138, PennDER Number 63-91), Ohio River Basin, Sawmill Creek, Washington County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Treated Water Pond (NDI Number PA 01138, PennDER Number 63-91), Ohio River Basin, Sawmill Creek, Washington County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 105 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Treated Water Pond (NDI Number PA 01138, PennDER Number 63-91), Ohio River Basin, Sawmill Creek, Washington County, Pennsylvania. Phase I Inspection Report by : ACKENHEIL AND ASSOCIATES INC PITTSBURGH PA.

Download or read book National Dam Safety Program. Treated Water Pond (NDI Number PA 01138, PennDER Number 63-91), Ohio River Basin, Sawmill Creek, Washington County, Pennsylvania. Phase I Inspection Report written by ACKENHEIL AND ASSOCIATES INC PITTSBURGH PA. and published by . This book was released on 1980 with total page 105 pages. Available in PDF, EPUB and Kindle. Book excerpt: The general condition of the Treated Water Pond is considered to be fair. This assessment is based primarily on visual observations of embankment conditions and lack of information on the structural capacity of conduits through the embankment. The structure is classified as an 'intermediate' size, 'high' hazard dam. Corps of Engineers guidelines recommend the Probable Maximum Flood (PMF) as the Spillway Design Flood for an 'intermediate' size, 'high' hazard dam. The Treated Water Pond's Spillway Design Flood is the Probable Maximum Flood. Spillway capacity is 'adequate' because the non-overtopping flood discharge was found, by using the HEC-1 computer program, to be in excess of 100 percent of the PMF. The visual inspection indicates several minor deficiencies in addition to those requiring further investigation. The deficiencies can be corrected or improved through implementation of the following recommended evaluation, remedial, monitoring and/or maintenance efforts.

National Dam Safety Program. Glades Dam (NDI Number PA-00804, Penn DER Number 10-72), Ohio River Basin, South Branch of Slippery Rock Creek, Butler County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Glades Dam (NDI Number PA-00804, Penn DER Number 10-72), Ohio River Basin, South Branch of Slippery Rock Creek, Butler County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 81 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Glades Dam (NDI Number PA-00804, Penn DER Number 10-72), Ohio River Basin, South Branch of Slippery Rock Creek, Butler County, Pennsylvania. Phase I Inspection Report by : Chuan Yuan Chen

Download or read book National Dam Safety Program. Glades Dam (NDI Number PA-00804, Penn DER Number 10-72), Ohio River Basin, South Branch of Slippery Rock Creek, Butler County, Pennsylvania. Phase I Inspection Report written by Chuan Yuan Chen and published by . This book was released on 1979 with total page 81 pages. Available in PDF, EPUB and Kindle. Book excerpt: Glades Dam is a homogeneous earthfill dam with a maximum height of 24 feet and a crest length of 960 feet. The dam, owned and operated by the Pennsylvania Game Commission, is used primarily for waterfowl protection. The spillway, consisting of a concrete ogee overflow with a slotted flip bucket energy dissipator, is located at the left abutment of the dam. The crest length is 100 feet. The discharge channel is lined with riprap for 130 feet downstream from the flip bucket. The intake tower and 54 inch outlet conduit are located 400 feet from the left abutment of the dam. Two 3 foot by 5 foot sluice gates (El. 1197.0 feet and El. 1190.0 feet) are used to control the pool elevation. The 54 inch reinforced concrete pressure pipe outlet conduit has four cut-off collars on 26 foot centers along the upstream portion. A discharge basin is located at the downstream end of the outlet conduit.

National Dam Inspection Program. Warner Dam (NDI Number PA 00975, PennDER Number 58-71), Susquehanna River Basin, Tributary of Snake Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report

Download National Dam Inspection Program. Warner Dam (NDI Number PA 00975, PennDER Number 58-71), Susquehanna River Basin, Tributary of Snake Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 67 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Inspection Program. Warner Dam (NDI Number PA 00975, PennDER Number 58-71), Susquehanna River Basin, Tributary of Snake Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report by : John A. Dziubek

Download or read book National Dam Inspection Program. Warner Dam (NDI Number PA 00975, PennDER Number 58-71), Susquehanna River Basin, Tributary of Snake Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report written by John A. Dziubek and published by . This book was released on 1981 with total page 67 pages. Available in PDF, EPUB and Kindle. Book excerpt: Warner Dam is owned by William S. Newlin, Jr., and is classified as a 'Low' hazard - 'Small' size dam. The dam was found to be in fair overall condition at the time of inspection. Hydraulic/hydrologic evaluations revealed that the spillway capacity is less than the peak inflow to the impoundment during the 100-year flood. A spillway design flood (SDF) in the range of the 50- year flood to the 100-year flood is required for Warner Dam. The 100-year flood was chosen as the SDF. The spillway is therefore considered 'Inadequate.' It is recommended that the owner immediately develop remedial measures to provide adequate spillway capacity. The inspection revealed certain items of remedial work which should be performed by the owner without delay. These include: (1) Provide adequate spillway capacity; (2) Repair the spalling on the downstream face of the concrete corewall; (3) Ensure that the outlet works are operable, or develop an emergency drawdown plan; and (4) Cut all trees on the embankment at ground level. All trees with a trunk diameter greater than 3 inches should have their root systems removed. All resultant areas of erosion and cavities should be filled, graded, compacted and seeded. In addition, the following operational measures are recommended to be undertaken by the owner: (1) Develop a detailed emergency operation and warning system; (2) During periods of unusually heavy rainfall, provide around-the-clock surveillance of the dam; and (3) When warning of a storm of major proportions is given by the National Weather Service, activate the emergency operation and warning system.

National Dam Safety Program. George B. Stevenson Dam (Inventory Number PA-914), Susquehanna River Basin, First Fork Sinnemahoning Creek, Cameron County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. George B. Stevenson Dam (Inventory Number PA-914), Susquehanna River Basin, First Fork Sinnemahoning Creek, Cameron County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 62 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. George B. Stevenson Dam (Inventory Number PA-914), Susquehanna River Basin, First Fork Sinnemahoning Creek, Cameron County, Pennsylvania. Phase I Inspection Report by : BERGER ASSOCIATES INC HARRISBURG PA.

Download or read book National Dam Safety Program. George B. Stevenson Dam (Inventory Number PA-914), Susquehanna River Basin, First Fork Sinnemahoning Creek, Cameron County, Pennsylvania. Phase I Inspection Report written by BERGER ASSOCIATES INC HARRISBURG PA. and published by . This book was released on 1978 with total page 62 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Dam Inspection Act, Public Law 92-367, authorized the Secretary of the Army, through the Corps of Engineers, to initiate a program of inspections of dams throughout the United States. The Phase I Inspection and Report are limited to a review of available data, a visual inspection of the dam site and basic calculations to determine the hydraulic adequacy of the spillway. The purpose is to determine if the dam constitutes a hazard to human life and property.

National Dam Safety Program. West Carroll Township Water and Sewer Authority Dam (Bakerton Dam) (NDI-PA-436), Susquehanna River Basin, West Branch Susquehanna River, Cambria County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. West Carroll Township Water and Sewer Authority Dam (Bakerton Dam) (NDI-PA-436), Susquehanna River Basin, West Branch Susquehanna River, Cambria County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 65 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. West Carroll Township Water and Sewer Authority Dam (Bakerton Dam) (NDI-PA-436), Susquehanna River Basin, West Branch Susquehanna River, Cambria County, Pennsylvania. Phase I Inspection Report by : CORPS OF ENGINEERS BALTIMORE MD BALTIMORE DISTRICT.

Download or read book National Dam Safety Program. West Carroll Township Water and Sewer Authority Dam (Bakerton Dam) (NDI-PA-436), Susquehanna River Basin, West Branch Susquehanna River, Cambria County, Pennsylvania. Phase I Inspection Report written by CORPS OF ENGINEERS BALTIMORE MD BALTIMORE DISTRICT. and published by . This book was released on 1978 with total page 65 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Dam Inspection Act, Public Law 92-367 authorized the Secretary of the Army, through the Corps of Engineers, to initiate a program of inspection of dams throughout the United States. The purpose is to determine if the dam constitutes a hazard to human life or property.

National Dam Safety Program. Tipton Dam (NDI I.D.-525), Susquehanna River Basin, Tipton Run, Blair County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Tipton Dam (NDI I.D.-525), Susquehanna River Basin, Tipton Run, Blair County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 68 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Tipton Dam (NDI I.D.-525), Susquehanna River Basin, Tipton Run, Blair County, Pennsylvania. Phase I Inspection Report by : D'APPOLONIA CONSULTING ENGINEERS PITTSBURGH PA.

Download or read book National Dam Safety Program. Tipton Dam (NDI I.D.-525), Susquehanna River Basin, Tipton Run, Blair County, Pennsylvania. Phase I Inspection Report written by D'APPOLONIA CONSULTING ENGINEERS PITTSBURGH PA. and published by . This book was released on 1978 with total page 68 pages. Available in PDF, EPUB and Kindle. Book excerpt: The inspection was performed pursuant to the authority granted by The National Dam Inspection Act, Public Law 92-367, to the Secretary of the Army, through the Corps of Engineers, to conduct inspections of dams throughout the United States. The purpose of this inspection is to determine if the dam constitutes a hazard to human life or property.

National Dam Safety Program. Dinsmore Storage Number 2 Dam. NDI Number PA-00497, PennDER Number 63-20. Ohio River Basin, Harmon Creek, Washington County, Commonwealth of Pennsylvania

Download National Dam Safety Program. Dinsmore Storage Number 2 Dam. NDI Number PA-00497, PennDER Number 63-20. Ohio River Basin, Harmon Creek, Washington County, Commonwealth of Pennsylvania PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 87 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Dinsmore Storage Number 2 Dam. NDI Number PA-00497, PennDER Number 63-20. Ohio River Basin, Harmon Creek, Washington County, Commonwealth of Pennsylvania by : John A. Dziubek

Download or read book National Dam Safety Program. Dinsmore Storage Number 2 Dam. NDI Number PA-00497, PennDER Number 63-20. Ohio River Basin, Harmon Creek, Washington County, Commonwealth of Pennsylvania written by John A. Dziubek and published by . This book was released on 1980 with total page 87 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report is prepared under guidance contained in the 'Recommended Guidelines for Safety Inspection of Dams, ' for Phase I Investigations. The purpose of a Phase I Investigation is to identify expeditiously those dams which may pose hazards to human life or property. The assessment of the general condition of the dam is based upon available data and visual inspections. Detailed investigation, and analyses involving topographic mapping, subsurface investigations, testing, and detailed computational evaluations are beyond the scope of a Phase I Investigation; however, the investigation is intended to identify any need for such studies.

National Dam Safety Program. Martindale Dam (NDI Number PA-00444, PennDER Number 11-17), Ohio River Basin, Trout Run, Cambria County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Martindale Dam (NDI Number PA-00444, PennDER Number 11-17), Ohio River Basin, Trout Run, Cambria County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 85 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Martindale Dam (NDI Number PA-00444, PennDER Number 11-17), Ohio River Basin, Trout Run, Cambria County, Pennsylvania. Phase I Inspection Report by : BAKER (MICHAEL) JR INC BEAVER PA.

Download or read book National Dam Safety Program. Martindale Dam (NDI Number PA-00444, PennDER Number 11-17), Ohio River Basin, Trout Run, Cambria County, Pennsylvania. Phase I Inspection Report written by BAKER (MICHAEL) JR INC BEAVER PA. and published by . This book was released on 1980 with total page 85 pages. Available in PDF, EPUB and Kindle. Book excerpt: Martindale Dam, owned and operated by the Borough of Portage Water Authority, is classified as a 'Small' size - 'High' hazard dam. The dam was found to be in fair overall condition at the time of inspection. Hydraulic/hydrologic evaluations, performed in accordance with procedures established by the Baltimore District, Corps of Engineers, for Phase I Inspection Reports, revealed that the dam, reservoir, and spillway will pass 16 percent of the Probable Maximum Flood (PMF) before overtopping of the dam occurs. A spillway design flood (SDF) in the range of the 1/2 Probable Maximum Flood (1/2 PMF) to the PMF is required for Martindale Dam. The 1/2 PMF was chosen as the SDF because the dam is on the low end of the 'Small' size category in terms of its storage and height. During the 1/2 PMF, the maximum depth and total duration of overtopping are 0.83 feet and 8.5 hours, respectively. Due to the relatively narrow crest width of the dam and the long duration of overtopping, it was judged that failure of the dam is likely during the 1/2 PMF. To assess the increase in damages downstream from the non-failure cases, the 1/2 PMF was routed through the dam and downstream for both conditions. It was determined that there would be a significant increase in economic damages and possible loss of life if the dam failed. The spillway is therefore categorized as being 'seriously inadequate.'

National Dam Safety Program. Bernhart Dam. NDI-PA-00717. PA DER-6-1. Delaware River Basin. Bernhart Creek, Berks County, Pennsylvania. Phase I Inspection Report

Download National Dam Safety Program. Bernhart Dam. NDI-PA-00717. PA DER-6-1. Delaware River Basin. Bernhart Creek, Berks County, Pennsylvania. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 74 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Bernhart Dam. NDI-PA-00717. PA DER-6-1. Delaware River Basin. Bernhart Creek, Berks County, Pennsylvania. Phase I Inspection Report by : O'BRIEN AND GERE ENGINEERS INC PHILADELPHIA PA JUSTIN AND COURTNEY DIV.

Download or read book National Dam Safety Program. Bernhart Dam. NDI-PA-00717. PA DER-6-1. Delaware River Basin. Bernhart Creek, Berks County, Pennsylvania. Phase I Inspection Report written by O'BRIEN AND GERE ENGINEERS INC PHILADELPHIA PA JUSTIN AND COURTNEY DIV. and published by . This book was released on 1979 with total page 74 pages. Available in PDF, EPUB and Kindle. Book excerpt: Bernhart Dam is an earth embankment with a masonry brick core wall. A 5-foot high masonry wall is located at the upstream edge of the top of the dam. The embankment is approximately 180 feet in length and has a maximum height of 30 feet. The side slopes are 2 horizontal to 1 vertical (2H:1V) upstream and 3H:1V downstream. The top of dam width varies between 22 and 35 feet. The dam impounds a reservoir with a normal pool storage capacity of 129 acre-feet. The reservoir was originally used for water supply but now serves only recreational purposes. A broad-crested spillway with a 40-foot crest length is located at the right abutment. The crest is at Elevation 395, 5 feet below the top of the dam. A masonry sidewall is provided along the left side of the spillway. The right sidewall of the spillway is formed by the nearly vertical rock abutment. The outlet channel is provided with masonry training walls along both sides for an approximate distance of 300 feet downstream.