Read Books Online and Download eBooks, EPub, PDF, Mobi, Kindle, Text Full Free.
Sixth Personnel Dosimetry Intercomparison Study
Download Sixth Personnel Dosimetry Intercomparison Study full books in PDF, epub, and Kindle. Read online Sixth Personnel Dosimetry Intercomparison Study ebook anywhere anytime directly on your device. Fast Download speed and no annoying ads. We cannot guarantee that every ebooks is available!
Book Synopsis Sixth Personnel Dosimetry Intercomparison Study by :
Download or read book Sixth Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1981 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The Sixth Personnel Dosimetry Intercomparison Study was conducted March 25 to 27, 1980, at the Oak Ridge National Laboratory. Dosimeters from 28 participating agencies were mounted on anthropomorphic phantoms and exposed to a range of low-level dose equivalents (1.8 to 11.5 mSv neutron, 0.1 to 1.1 mSv gamma) which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor (HPRR) operated in the steady-state mode served as the source of radiation for six separate exposures. Lucite and concrete shields along with the unshielded reactor were used to provide three different neutron and gamma spectra. Results reported by the participating agencies showed that TLD-albedo and TLD-700 dosimeters generally provided the most accurate measurements of neutron and gamma dose equivalents, respectively. Film was found to be unsatisfactory for measuring neutron doses produced by HPRR spectra in that measured dose equivalents were much lower than reference values. The TLD-100 dosimeters yielded gamma doses which were much too high indicating that this dosimeter type is generally unsuitable for use in mixed radiation fields similar to those encountered in this study without the use of large correction factors. Although the overall reported results exhibited improvement in performance relative to previous intercomparison studies, the composite measured data showed variations of more than a factor of 2 between measurements of the same exposure made by different agencies.
Book Synopsis Fifth personnel dosimetry intercomparison study by : C. S. Sims
Download or read book Fifth personnel dosimetry intercomparison study written by C. S. Sims and published by . This book was released on 1980 with total page 69 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book Energy Research Abstracts written by and published by . This book was released on 1992 with total page 806 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Fourth Personnel Dosimetry Intercomparison Study by : H. W. Dickson
Download or read book Fourth Personnel Dosimetry Intercomparison Study written by H. W. Dickson and published by . This book was released on 1980 with total page 36 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Personnel Dosimetry Intercomparison Study by : Oak Ridge National Laboratory
Download or read book Personnel Dosimetry Intercomparison Study written by Oak Ridge National Laboratory and published by . This book was released on 1979 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Seventh Personnel Dosimetry Intercomparison Study by :
Download or read book Seventh Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1981 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The Seventh Personnel Dosimetry Intercomparison Study was conducted March 31-April 10, 1981, at the Oak Ridge National Laboratory. Dosimeters from 34 participating agencies were mounted on anthropomorphic phantoms and exposed to a range of low-level dose equivalents (1.5-15.0mSv neutron and 0.1-2.8 mSv gamma) which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor, operating in the steady-state mode, served as the source of radiation for two equivalent sets of six separate exposures. Lucite and concrete shields along with the unshielded reactor provided three different neutron and gamma spectra for five of the exposures in each set. Results reported by the participating agencies showed that no single type of neutron dosimeter exhibited acceptable performance characteristics for all mixed-field environments encountered in this study. Film, TLD, and TLD-albed dosimeters were found to be inadequate for neutron dose equivalent measurements when large numbers of slow neutrons are present unless significant corrections are made to measured results. Track dosimeters indicated the least sensitivity to spectral characteristics, but did not always yield to the most accurate results. Gamma dose measurements showed that TLD-700 dosimeters produced significantly more accurate results than film dosimeters which tend to overestimate gamma doses in mixed radiation fields.
Book Synopsis Third Personnel Dosimetry Intercomparison Study by : L. W. Gilley
Download or read book Third Personnel Dosimetry Intercomparison Study written by L. W. Gilley and published by . This book was released on 1979 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Fifth Personnel Dosimetry Intercomparison Study by :
Download or read book Fifth Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1980 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The fifth Personnel Dosimetry Intercomparison Study (PDIS) was conducted at the Oak Ridge National Laboratory's (ORNL) Dosimetry Applications Research (DOSAR) facility on March 20-22, 1979. This study is the latest PDIS in the continuing series started at the DOSAR facility in 1974. The PDIS is a three day study, typically in March, where personnel dosimeters are mailed to the DOSAR facility, exposed to a range of low-level neutron radiation doses (1 to 15 mSv or equivalently, 100 to 1500 mrem) and neutron-to-gamma ratios (1:1-10:1) using the Health Physics Research Reactor (HPRR) as the radiation source, and returned to the participants for evaluation. This report is a summary and analysis of the results reported by the various participants. The participants are able to intercompare their results with those of others who made dose measurements under identical experimental conditions.
Book Synopsis Fourth Personnel Dosimetry Intercomparison Study by :
Download or read book Fourth Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1980 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The fourth Personnel Dosimetry Intercomparison Study was held at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during March 15-23, 1978. The Health Physics Research Reactor (HPRR) used unshielded, with a 12-cm-thick Lucite shield, a 20-cm-thick concrete shield, or a 5-cm-thick steel and 15-cm-thick concrete shield, and provided four neutron and gamma-ray spectra. Then the dose was calculated based on the HPRR neutron spectra and dose conversion factors which had been determined previously for the four spectra. The results of these personnel dosimetry intercomparison studies reveal that estimates of dose equivalent vary over a wide range. The standard deviation of the mean of participants data for gamma measurements was in the range of 29 to 43%; for neutrons it was 57 to 188%. (PCS).
Book Synopsis Tenth ORNL Personnel Dosimetry Intercomparison Study by : R. E. Swaja
Download or read book Tenth ORNL Personnel Dosimetry Intercomparison Study written by R. E. Swaja and published by . This book was released on 1985 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Third Personnel Dosimetry Intercomparison Study by :
Download or read book Third Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1979 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The third Personnel Dosimetery Intercomparison Study was held at the Oak Ridge National Laboratory Dosimetry Applications Research Facility during March 15--16, 1977. The Health Physics Research Reactor (HPRR), used unshielded, with a 12-cm-thick Lucite shield or a 13-cm-thick steel shield, provided three neutron and gamma-ray spectra. The characteristics of these fields such as neutron energy spectra, intensity, and uniformity had been measured previously during nuclear accident dosimetry studies. Exposures were made to simulate total exposures likely to be encountered in personnel dosimetry. Neutron dose equivalents of the order of 500 millirem were produced by controlling the reactor power level and exposure time. Dosimeters were mounted on the trunk section of water-filled phantoms, the front edges of which were located 3 m from the reactor center. When shields were used they were placed at 2 m from the core. Sulfur pellets exposed at a standard location on the reactor during the intercomparison were used to calculate values of tissue kerma for neutrons at the 3-m position based on previous measurements. Using the fission yield and the calculated leakage of the HPRR, the neutron fluence was calculated for each reactor run. Then the dose was calculated based on the HPRR neutron spectra and the dose conversion factors, which had been calculated previously for the three spectra. The results of these personnel dosimetry intercomparison studies reveal that estimates of dose equivalent vary over a wide range. The standard deviation of the mean of participants data was in the range of 25 to 50%.
Book Synopsis Health and Safety Research Division Progress Report for the Period ... by :
Download or read book Health and Safety Research Division Progress Report for the Period ... written by and published by . This book was released on 1979-10 with total page 116 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book Nuclear Science Abstracts written by and published by . This book was released on 1976 with total page 1288 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book NBS Special Publication written by and published by . This book was released on 1968 with total page 476 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book Technical Reports Series written by and published by . This book was released on 1985 with total page 870 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Government Reports Announcements & Index by :
Download or read book Government Reports Announcements & Index written by and published by . This book was released on 1988 with total page 1132 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Energy Meetings by : United States. Department of Energy. Technical Information Center
Download or read book Energy Meetings written by United States. Department of Energy. Technical Information Center and published by . This book was released on 1985 with total page 684 pages. Available in PDF, EPUB and Kindle. Book excerpt: A listing of forthcoming meetings, conventions, etc.