Performance of a High Resolution Cavity Beam Position Monitor System

Download Performance of a High Resolution Cavity Beam Position Monitor System PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 28 pages
Book Rating : 4.:/5 (893 download)

DOWNLOAD NOW!


Book Synopsis Performance of a High Resolution Cavity Beam Position Monitor System by :

Download or read book Performance of a High Resolution Cavity Beam Position Monitor System written by and published by . This book was released on 2006 with total page 28 pages. Available in PDF, EPUB and Kindle. Book excerpt: It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than one nanometer. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 [mu]rad over a dynamic range of approximately ± 20 [mu]m.

Resolution of a High Performance Cavity Beam Position Monitor System

Download Resolution of a High Performance Cavity Beam Position Monitor System PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 3 pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Resolution of a High Performance Cavity Beam Position Monitor System by :

Download or read book Resolution of a High Performance Cavity Beam Position Monitor System written by and published by . This book was released on 2007 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Resolution of a High Performance Cavity Beam Positron Monitor System

Download Resolution of a High Performance Cavity Beam Positron Monitor System PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 3 pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Resolution of a High Performance Cavity Beam Positron Monitor System by :

Download or read book Resolution of a High Performance Cavity Beam Positron Monitor System written by and published by . This book was released on 2007 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved--ideally using beam-based stability measurements. It has been estimated that RF cavity beam position monitors (BPMs) could provide position measurement resolutions of less than one nanometer and could form the basis of the desired beam-based stability measurement. We have developed a high resolution RF cavity BPM system. A triplet of these BPMs has been installed in the extraction line of the KEK Accelerator Test Facility (ATF) for testing with its ultra-low emittance beam. A metrology system for the three BPMs was recently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame and has demonstrated that the three BPMs behave as a rigid-body to less than 5 nm. To date, we have demonstrated a BPM resolution of less than 20 nm over a dynamic range of +/- 20 microns.

Development of High-resolution Cavity Beam Position Monitors for Use in Low-latency Feedback Systems

Download Development of High-resolution Cavity Beam Position Monitors for Use in Low-latency Feedback Systems PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Development of High-resolution Cavity Beam Position Monitors for Use in Low-latency Feedback Systems by : Talitha Bromwich

Download or read book Development of High-resolution Cavity Beam Position Monitors for Use in Low-latency Feedback Systems written by Talitha Bromwich and published by . This book was released on 2018 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Beam Diagnostics in Superconducting Accelerating Cavities

Download Beam Diagnostics in Superconducting Accelerating Cavities PDF Online Free

Author :
Publisher : Springer Science & Business Media
ISBN 13 : 3319007599
Total Pages : 128 pages
Book Rating : 4.3/5 (19 download)

DOWNLOAD NOW!


Book Synopsis Beam Diagnostics in Superconducting Accelerating Cavities by : Pei Zhang

Download or read book Beam Diagnostics in Superconducting Accelerating Cavities written by Pei Zhang and published by Springer Science & Business Media. This book was released on 2013-07-24 with total page 128 pages. Available in PDF, EPUB and Kindle. Book excerpt: An energetic charged particle beam introduced to an rf cavity excites a wakefield therein. This wakefield can be decomposed into a series of higher order modes and multipoles, which for sufficiently small beam offsets are dominated by the dipole component. This work focuses on using these dipole modes to detect the beam position in third harmonic superconducting S-band cavities for light source applications. A rigorous examination of several means of analysing the beam position based on signals radiated to higher order modes ports is presented. Experimental results indicate a position resolution, based on this technique, of 20 microns over a complete module of 4 cavities. Methods are also indicated for improving the resolution and for applying this method to other cavity configurations. This work is distinguished by its clarity and potential for application to several other international facilities. The material is presented in a didactic style and is recommended both for students new to the field, and for scientists well-versed in the field of rf diagnostics.

The Electric Dipole Moment Challenge

Download The Electric Dipole Moment Challenge PDF Online Free

Author :
Publisher : Morgan & Claypool Publishers
ISBN 13 : 1681745100
Total Pages : 238 pages
Book Rating : 4.6/5 (817 download)

DOWNLOAD NOW!


Book Synopsis The Electric Dipole Moment Challenge by : Richard Talman

Download or read book The Electric Dipole Moment Challenge written by Richard Talman and published by Morgan & Claypool Publishers. This book was released on 2017-05-18 with total page 238 pages. Available in PDF, EPUB and Kindle. Book excerpt: The electric dipole moment (EDM) challenge measures a non-zero proton EDM value and this book suggests how the challenge can be met. Any measurably large proton EDM would violate the standard model. The method to be employed uses an intense beam of 'frozen spin' protons circulating for hour-long times in a storage ring 'trap'. The smallness of EDMs allows them to test existing theories, but also makes them hard to measure. Such EDM experiments are inexpensive, at least compared to building accelerators of ever-greater energy.

Cavity Beam Position Monitor System for ATF2

Download Cavity Beam Position Monitor System for ATF2 PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 3 pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Cavity Beam Position Monitor System for ATF2 by :

Download or read book Cavity Beam Position Monitor System for ATF2 written by and published by . This book was released on 2012 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance. The ATF2 C-band system is performing well, with individual CBPM resolution approaching or at the design resolution of 50 nm. The changes in the CBPM calibration observed over three weeks can probably be attributed to thermal effects on the mixer electronics systems. The CW calibration tone power will be upgraded to monitor changes in the electronics gain and phase. The four S-band CBPMs are still to be investigated, the main problem associated with these cavities is a large cross coupling between the x and y ports. This combined with the large design dispersion in that degion makes the digital signal processing difficult, although various techniques exist to determine the cavity parameters and use these coupled signals for beam position determination.

Design and Performance of the LCLS Cavity BPM System

Download Design and Performance of the LCLS Cavity BPM System PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Design and Performance of the LCLS Cavity BPM System by :

Download or read book Design and Performance of the LCLS Cavity BPM System written by and published by . This book was released on 2008 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM010 monopole reference cavity and a TM110 dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

High-Precision Resonant Cavity Beam Position, Emittance And Third-Moment Monitors

Download High-Precision Resonant Cavity Beam Position, Emittance And Third-Moment Monitors PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 3 pages
Book Rating : 4.:/5 (316 download)

DOWNLOAD NOW!


Book Synopsis High-Precision Resonant Cavity Beam Position, Emittance And Third-Moment Monitors by : R. H. Miller

Download or read book High-Precision Resonant Cavity Beam Position, Emittance And Third-Moment Monitors written by R. H. Miller and published by . This book was released on 2006 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: Linear colliders and FEL facilities need fast, nondestructive beam position and profile monitors to facilitate machine tune-up, and for use with feedback control. FAR-TECH, Inc., in collaboration with SLAC, is developing a resonant cavity diagnostic to simultaneously measure the dipole, quadrupole and sextupole moments of the beam distribution. Measurements of dipole and quadrupole moments at multiple locations yield information about beam orbit and emittance. The sextupole moment can reveal information about beam asymmetry which is useful in diagnosing beam tail deflections caused by short-range dipole wakefields. In addition to the resonance enhancement of a single-cell cavity, use of a multi-cell standing-wave structure further enhances signal strength and improves the resolution of the device. An estimated resolution is better than 1 {micro}m in rms beam size and better than 1 nm in beam position.

Particle Physics Reference Library

Download Particle Physics Reference Library PDF Online Free

Author :
Publisher : Springer Nature
ISBN 13 : 303034245X
Total Pages : 867 pages
Book Rating : 4.0/5 (33 download)

DOWNLOAD NOW!


Book Synopsis Particle Physics Reference Library by : Stephen Myers

Download or read book Particle Physics Reference Library written by Stephen Myers and published by Springer Nature. This book was released on 2020-01-01 with total page 867 pages. Available in PDF, EPUB and Kindle. Book excerpt: This third open access volume of the handbook series deals with accelerator physics, design, technology and operations, as well as with beam optics, dynamics and diagnostics. A joint CERN-Springer initiative, the "Particle Physics Reference Library" provides revised and updated contributions based on previously published material in the well-known Landolt-Boernstein series on particle physics, accelerators and detectors (volumes 21A,B1,B2,C), which took stock of the field approximately one decade ago. Central to this new initiative is publication under full open access.

EXPERIMENTAL RESULTS FROM A MICROWAVE CAVITY BEAM POSITION MONITOR.

Download EXPERIMENTAL RESULTS FROM A MICROWAVE CAVITY BEAM POSITION MONITOR. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 6 pages
Book Rating : 4.:/5 (682 download)

DOWNLOAD NOW!


Book Synopsis EXPERIMENTAL RESULTS FROM A MICROWAVE CAVITY BEAM POSITION MONITOR. by :

Download or read book EXPERIMENTAL RESULTS FROM A MICROWAVE CAVITY BEAM POSITION MONITOR. written by and published by . This book was released on 1999 with total page 6 pages. Available in PDF, EPUB and Kindle. Book excerpt: Future Linear Colliders have hard requirements for the beam transverse position stability in the accelerator. A beam Position Monitor (BPM) with the resolution better than 0.1 micron in the single bunch regime is needed to control the stability of the beam position along the linac. Proposed BPM is based on the measurement of the asymmetrical mode excited by single bunch in the cavity. Four stages of signal processing (space-, time-, frequency- and phase-filtering providing the required signal-to-noise ratio) are used to obtain extremely high resolution. The measurement set-up was designed by BINP and installed at ATF/BNL to test experimentally this concept. The set-up includes three two-coordinates BPM's at the frequency of 13.566 GHz, and reference intensity/phase cavity. BPM's were mounted on support table. The two-coordinates movers allow to move and align BPM's along the straight line, using the signals from the beam. The position of each monitor is controlled by the sensors with the accuracy 0.03 micron. The information from three monitors allows to exclude angle and position jitter of the beam and measure BPM resolution. In the experiments the resolution of about 0.15 micron for 0.25 nC beam intensity was obtained, that is close to the value required.

Physics and Engineering of High-performance Electron Storage Rings and Application of Superconducting Technology

Download Physics and Engineering of High-performance Electron Storage Rings and Application of Superconducting Technology PDF Online Free

Author :
Publisher : World Scientific
ISBN 13 : 9812778411
Total Pages : 567 pages
Book Rating : 4.8/5 (127 download)

DOWNLOAD NOW!


Book Synopsis Physics and Engineering of High-performance Electron Storage Rings and Application of Superconducting Technology by : Shin-Ichi Kurokawa

Download or read book Physics and Engineering of High-performance Electron Storage Rings and Application of Superconducting Technology written by Shin-Ichi Kurokawa and published by World Scientific. This book was released on 2002 with total page 567 pages. Available in PDF, EPUB and Kindle. Book excerpt: The first Asian Accelerator School (AAS) was organised to show the rapid development of accelerator sciences based on electron storage rings in Asia. At present seven electronOCopositron colliders are operational in the world, and two of them are located in Asia: KEKB (the KEK B-Factory) at KEK in Japan, and BEPC at IHEP in China. It is also notable that one-third of the operating synchrotron light sources are Asian machines.To further improve the performance of electron storage rings, the use of superconducting magnets and cavities is of vital importance; therefore the curriculum of AAS was arranged not only to teach the basic physics of storage rings but also to give students a basic knowledge of superconducting technology."

Digital Beam Position Monitor for the Happex Experiment

Download Digital Beam Position Monitor for the Happex Experiment PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (316 download)

DOWNLOAD NOW!


Book Synopsis Digital Beam Position Monitor for the Happex Experiment by : J. Musson

Download or read book Digital Beam Position Monitor for the Happex Experiment written by J. Musson and published by . This book was released on 2005 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The proposed HAPPEX experiment at CEBAF employs a three cavity monitor system for high-precision (1 mm), high-bandwidth (100 kHz) position measurements. This is performed using a cavity triplet consisting of two TM110-mode cavities (one each for X and Y planes) combined with a conventional TM-010-mode cavity for a phase and magnitude reference. Traditional systems have used the TM010 cavity output to directly down convert the BPM cavity signals to base band. The Multi-channel HAPPEX digital receiver simultaneously I/Q samples each cavity and extracts position using a CORDIC algorithm. The hardware design consists of a digital receiver daughter board and digital processor motherboard that resides in a VXI crate. The daughter board down converts 1.497 GHz signals from the TM010 cavity and X and Y signals from the TM110 cavities to 4 MHz, and extracts the quadrature digital signals. The motherboard processes this data and computes beam intensity and X-Y positions with a resolution of one mm, 100 kHz output bandwidth, and overall latency of ten microseconds. The results are available in both analog and digital format.

Design of a Standing-Wave Multi-Cavity Beam-Monitor for Simultaneous Beam Position and Emittance Measurements

Download Design of a Standing-Wave Multi-Cavity Beam-Monitor for Simultaneous Beam Position and Emittance Measurements PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 7 pages
Book Rating : 4.:/5 (316 download)

DOWNLOAD NOW!


Book Synopsis Design of a Standing-Wave Multi-Cavity Beam-Monitor for Simultaneous Beam Position and Emittance Measurements by : R. Miller

Download or read book Design of a Standing-Wave Multi-Cavity Beam-Monitor for Simultaneous Beam Position and Emittance Measurements written by R. Miller and published by . This book was released on 2005 with total page 7 pages. Available in PDF, EPUB and Kindle. Book excerpt: A high precision emittance measurement requires precise beam position at the measurement location. At present there is no existing technique, commercial or otherwise, for non-destructive pulse-to-pulse simultaneous beam position and emittance measurement. FARTECH, Inc. is currently developing a high precision cavity-based beam monitor for simultaneous beam position and emittance measurements pulse-to-pulse, without beam interception and without moving parts. The design and analysis of a multi-cavity standing wave structure for a pulse-to-pulse emittance measurement system in which the quadrupole and the dipole standing wave modes resonate at harmonics of the beam operating frequency is presented. Considering the Next Linear Collider beams, an optimized 9-cavity standing wave system is designed for simultaneous high precision beam position and emittance measurements. It operates with the {pi}-quadrupole mode resonating at 16th harmonic of the NLC bunch frequency, and the 3 {pi}/4 dipole mode at 12th harmonic (8.568 GHz). The 9-cavity system design indicates that the two dipoles resonate almost at the same frequency 8.583 GHz and the quadrupole at 11.427 GHz according to the scattering parameter calculations. The design can be trivially scaled so that the dipole frequency is at 8.568 GHz, and the quadrupole frequency can then be tuned during fabrication to achieve the desired 11.424 GHz. The output powers from these modes are estimated for the NLC beams. An estimated rms-beam size resolution is sub micro-meters and beam positions in sub nano-meters.

Performance of the Beam Position Monitor for the Advanced Photon Source

Download Performance of the Beam Position Monitor for the Advanced Photon Source PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (683 download)

DOWNLOAD NOW!


Book Synopsis Performance of the Beam Position Monitor for the Advanced Photon Source by :

Download or read book Performance of the Beam Position Monitor for the Advanced Photon Source written by and published by . This book was released on 2001 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Performance measurement and analysis of the Advanced Photon Source (APS) beam position monitor (BPM) electronics are reported. The results indicate a BPM resolution of 0.16[mu]m[center-dot]mA/[radical]Hz in terms of the single-bunch current and BPM bandwidth. For the miniature insertion device (ID) BPM, the result was 0.1[mu]m[center-dot]mA/[radical]Hz. The improvement is due to the 3.6 times higher position sensitivity (in the vertical plane), which is partially canceled by the lower button signal by a factor of 2.3. The minimum single-bunch current required was roughly 0.03 mA. The long-term drift of the BPM electronics independent of the actual beam motion was measured at 2[mu]m/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Implications of the BPM resolution limit on the global and local orbit feedback systems for the APS storage ring will also be discussed.

Development of a High-precision Low-latency Position Feedback System for Single-pass Beamlines Using Stripline and Cavity Beam Position Monitors

Download Development of a High-precision Low-latency Position Feedback System for Single-pass Beamlines Using Stripline and Cavity Beam Position Monitors PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (951 download)

DOWNLOAD NOW!


Book Synopsis Development of a High-precision Low-latency Position Feedback System for Single-pass Beamlines Using Stripline and Cavity Beam Position Monitors by : Neven Blaskovic Kraljevic

Download or read book Development of a High-precision Low-latency Position Feedback System for Single-pass Beamlines Using Stripline and Cavity Beam Position Monitors written by Neven Blaskovic Kraljevic and published by . This book was released on 2015 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Nuclear Science Abstracts

Download Nuclear Science Abstracts PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 680 pages
Book Rating : 4.E/5 ( download)

DOWNLOAD NOW!


Book Synopsis Nuclear Science Abstracts by :

Download or read book Nuclear Science Abstracts written by and published by . This book was released on 1976 with total page 680 pages. Available in PDF, EPUB and Kindle. Book excerpt: