MESURE IN SITU DE LA FONCTION DE PHASE DE DIFFUSION DES PARTICULES NUAGEUSES AU MOYEN DU NEPHELOMETRE POLAIRE AEROPORTE

Download MESURE IN SITU DE LA FONCTION DE PHASE DE DIFFUSION DES PARTICULES NUAGEUSES AU MOYEN DU NEPHELOMETRE POLAIRE AEROPORTE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 151 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis MESURE IN SITU DE LA FONCTION DE PHASE DE DIFFUSION DES PARTICULES NUAGEUSES AU MOYEN DU NEPHELOMETRE POLAIRE AEROPORTE by : FREDERIQUE.. AURIOL

Download or read book MESURE IN SITU DE LA FONCTION DE PHASE DE DIFFUSION DES PARTICULES NUAGEUSES AU MOYEN DU NEPHELOMETRE POLAIRE AEROPORTE written by FREDERIQUE.. AURIOL and published by . This book was released on 1998 with total page 151 pages. Available in PDF, EPUB and Kindle. Book excerpt: LA COMPREHENSION DU ROLE DES NUAGES SUR LE CLIMAT GLOBAL DE NOTRE PLANETE PASSE PAR L'ETUDE DES INTERACTIONS ENTRE MICROPHYSIQUE ET RAYONNEMENT ET DONC PAR LA CONNAISSANCE DES PROPRIETES MICROPHYSIQUES ET OPTIQUES DES NUAGES. LE NEPHELOMETRE POLAIRE AEROPORTE A ETE DEVELOPPE AFIN DE REPONDRE AU DOUBLE OBJECTIF DE FOURNIR DES MESURES IN SITU DIRECTES DE L'INDICATRICE DE DIFFUSION DES NUAGES ET D'AMELIORER LA QUALITE DES MESURES DES CARACTERISTIQUES MICROPHYSIQUES DES NUAGES, EN PARTICULIER DANS LES NUAGES GLACES. DES MESURES ORIGINALES DE L'INDICATRICE DE DIFFUSION ONT ETE REALISEES EN STRATOCUMULUS, CIRRUS ET CONTRAILS LORS DE L'EXPERIENCE EUROPEENNE AEROCONTRAIL. DANS LES NUAGES D'EAU LIQUIDE, LE NEPHELOMETRE POLAIRE A PU ETRE VALIDE AU NIVEAU DE LA MESURE DE LA FONCTION DE PHASE DE DIFFUSION, D'UNE PART ET D'AUTRE PART, POUR LA RESTITUTION DES PARAMETRES MICROPHYSIQUES A L'AIDE D'UNE METHODE D'INVERSION. DANS LES NUAGES MIXTES, UN CRITERE TRES SENSIBLE PERMET DE CONNAITRE LA PHASE DU NUAGE ECHANTILLONNE. LES FONCTIONS DE PHASE DE DIFFUSION MESUREES DANS LES NUAGES GLACES DE TYPE CIRRUS OU CONTRAIL INDIQUENT DES DIFFERENCES MAJEURES AVEC LES FONCTIONS DE PHASE SOUVENT UTILISEES DANS LES MODELES QUI FONT L'HYPOTHESE DE PARTICULES SPHERIQUES OU DE FORMES GEOMETRIQUES SIMPLES POUR LES CRISTAUX DE GLACE. L'INTERPRETATION DES FONCTIONS DE PHASE MESUREES MONTRE L'IMPORTANCE DES EFFETS DE FORME OU DE RUGOSITE DES PARTICULES SUR L'INDICATRICE DE DIFFUSION. ENFIN, LE NEPHELOMETRE POLAIRE PERMET D'ESTIMER LA TAILLE, LA CONCENTRATION ET LE CONTENU EN GLACE DES CRISTAUX DE DIAMETRE INFERIEUR A 40 M.

Proceedings

Download Proceedings PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 700 pages
Book Rating : 4.8/5 (199 download)

DOWNLOAD NOW!


Book Synopsis Proceedings by :

Download or read book Proceedings written by and published by . This book was released on 2000 with total page 700 pages. Available in PDF, EPUB and Kindle. Book excerpt:

CONCEPTION ET REALISATION D'UN NEPHELOMETRE POLAIRE POUR LA MESURE DES PARAMETRES OPTIQUES ET MICROPHYSIQUES DES NUAGES

Download CONCEPTION ET REALISATION D'UN NEPHELOMETRE POLAIRE POUR LA MESURE DES PARAMETRES OPTIQUES ET MICROPHYSIQUES DES NUAGES PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (116 download)

DOWNLOAD NOW!


Book Synopsis CONCEPTION ET REALISATION D'UN NEPHELOMETRE POLAIRE POUR LA MESURE DES PARAMETRES OPTIQUES ET MICROPHYSIQUES DES NUAGES by : Olivier Crepel

Download or read book CONCEPTION ET REALISATION D'UN NEPHELOMETRE POLAIRE POUR LA MESURE DES PARAMETRES OPTIQUES ET MICROPHYSIQUES DES NUAGES written by Olivier Crepel and published by . This book was released on 1995 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: LA COMPREHENSION DU ROLE DES NUAGES SUR LE CLIMAT NECESSITE UNE DESCRIPTION DETAILLEE DE LEURS PROPRIETES OPTIQUES ET MICROPHYSIQUES. LE PROTOTYPE DE NEPHELOMETRE AEROPORTE PRESENTE DANS CE MANUSCRIT A ETE DEVELOPPE DANS LE DOUBLE OBJECTIF DE MESURER LES PROPRIETES OPTIQUES DES PARTICULES NUAGEUSES ET DE DETERMINER LEUR GRANULOMETRIE. LE PRINCIPE DE MESURE REPOSE DONC SUR LA MESURE DIRECTE DE L'INDICATRICE DE DIFFUSION D'UNE POPULATION DE PARTICULES. DANS LE CAS DES PARTICULES SPHERIQUES (GOUTTELETTES D'EAU), UNE METHODE NUMERIQUE D'INVERSION PERMET DE RESTITUER LE SPECTRE DIMENSIONNEL ; DANS LE CAS DE FORMES NON SPHERIQUES (CRISTAUX DE GLACE), L'INDICATRICE DE DIFFUSION APPORTE UNE INFORMATION SUR LA FORME ET LA COMPOSITION DES PARTICULES DIFFUSANTES. LES ESSAIS MENES EN SOUFFLERIE ONT PERMIS DE TESTER LE PROTOTYPE EN CONDITIONS NUAGEUSES NATURELLES. CES ESSAIS ONT MONTRE L'EXCELLENT COMPORTEMENT DU NEPHELOMETRE, TANT EN NUAGE LIQUIDE OU LA METHODE D'INVERSION A ETE UTILISEE AVEC SUCCES, QU'EN PHASE MIXTE, OU LA SIGNATURE OPTIQUE DES CRISTAUX DE GLACE A PU ETRE IDENTIFIEE. DES MESURES REALISEES EN CHAMBRE A NUAGES SONT EGALEMENT PRESENTEES

ETUDE EXPERIMENTALE DE L'INDICATRICE DE DIFFUSION DES PARTICULES NON-SPHERIQUES

Download ETUDE EXPERIMENTALE DE L'INDICATRICE DE DIFFUSION DES PARTICULES NON-SPHERIQUES PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 242 pages
Book Rating : 4.:/5 (834 download)

DOWNLOAD NOW!


Book Synopsis ETUDE EXPERIMENTALE DE L'INDICATRICE DE DIFFUSION DES PARTICULES NON-SPHERIQUES by : Jean-Marc Andre

Download or read book ETUDE EXPERIMENTALE DE L'INDICATRICE DE DIFFUSION DES PARTICULES NON-SPHERIQUES written by Jean-Marc Andre and published by . This book was released on 2000 with total page 242 pages. Available in PDF, EPUB and Kindle. Book excerpt: POUR COMPRENDRE ET MODELISER L'IMPACT DES AEROSOLS SUR LE CLIMAT ET L'ENVIRONNEMENT, IL EST NECESSAIRE D'AVOIR UNE IMAGE GLOBALE DE LA QUANTITE D'AEROSOLS ATMOSPHERIQUES, DE LEURS PRINCIPALES CARACTERISTIQUES AINSI QUE DE LEURS VARIATIONS TEMPORELLES. LE NEPHELOMETRE POLAIRE DE LABORATOIRE DEVELOPPE ET DECRIT DANS CETTE THESE PERMET DE CARACTERISER LES PROPRIETES OPTIQUES D'UNE POPULATION D'AEROSOLS PAR LA MESURE DE L'INDICATRICE DE DIFFUSION SUIVANT DEUX DIRECTIONS DE POLARISATIONS PERPENDICULAIRES. LA POLARISATION PERPENDICULAIRE AU PLAN DE DIFFUSION MESURE L'INDICATRICE DE DIFFUSION ENTRE 10 O ET 161 O ET LA POLARISATION PARALLELE ENTRE 19 O ET 170 O. LES DEUX MESURES ONT UNE RESOLUTION ANGULAIRE DE 1 O. CETTE MESURE DE DOUBLE POLARISATION SE FAIT PAR UNE MESURE DIRECTE (SANS MIROIR) DE LA LUMIERE DIFFUSEE. LA METHODE D'INVERSION UTILISEE, EN SUPPOSANT LES PARTICULES SPHERIQUES, PERMET LA RESTITUTION DE LA GRANULOMETRIE, MAIS, NE PERMET PAS ENCORE DE S'AFFRANCHIR DE LA CONNAISSANCE DE L'INDICE DE REFRACTION COMPLEXE. LES MESURES REALISEES JUSQU'A PRESENT ONT PERMIS DE MONTRER QUE LA METHODE D'INVERSION DONNAIT DES RESULTATS SATISFAISANTS DANS LE CAS DE PARTICULES SPHERIQUES. MAIS CES MESURES ONT AUSSI MONTRE LA LIMITE DE CETTE METHODE DANS LE CAS DE L'INTERPRETATION DES LUMIERES POLARISEES DIFFUSEES LORSQUE LES PARTICULES NE SONT PAS SPHERIQUES. CETTE METHODE D'INVERSION DOIT DONC ETRE MODIFIEE POUR POUVOIR UTILISER CET INNOVANT NEPHELOMETRE DE LABORATOIRE DE FACON OPTIMUM.