ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D'UN SPECTROMETRE D'EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D'ANALYSE ELEMENTAIRE

Download ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D'UN SPECTROMETRE D'EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D'ANALYSE ELEMENTAIRE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D'UN SPECTROMETRE D'EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D'ANALYSE ELEMENTAIRE by : MARTINE.. CARRE JOUINEAU

Download or read book ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D'UN SPECTROMETRE D'EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D'ANALYSE ELEMENTAIRE written by MARTINE.. CARRE JOUINEAU and published by . This book was released on 1991 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: LE PLASMA A COUPLAGE INDUCTIF (ICP) EST UNE SOURCE LARGEMENT UTILISEE EN ANALYSE ELEMENTAIRE PAR SPECTROMETRIE D'EMISSION OPTIQUE. UNE INSTALLATION COMMERCIALE TYPIQUE VA COMPRENDRE: LE PLASMA LUI-MEME, UN GENERATEUR QUI APPORTE L'ENERGIE, UN SYSTEME D'INTRODUCTION D'ECHANTILLON QUI PERMET D'INTRODUIRE LE LIQUIDE DANS LA DECHARGE, UN SYSTEME DE DETECTION OPTIQUE ET UNE CHAINE D'ACQUISITION DU SIGNAL. AFIN D'AMELIORER LE RAPPORT SIGNAL SUR BRUIT DU JY 38 PLUS, COMMERCIALISE PAR JOBIN YVON, NOUS AVONS ETUDIE LES PRINCIPALES CAUSES D'INSTABILITE DUES A CHAQUE PARTIE DE L'APPAREIL. DANS UN PREMIER TEMPS, NOUS AVONS OPTIMISE LES CONDITIONS DE SOURCE POUR OBTENIR LE PLASMA LE PLUS STABLE ET LE PLUS PERFORMANT POSSIBLE. POUR CELA, NOUS AVONS ETUDIE L'INFLUENCE DES DEBITS DE GAZ ET DE LA PUISSANCE DU GENERATEUR SUR LA STABILITE DE L'EMISSION. ENSUITE UNE ETUDE GRANULOMETRIQUE ET VELOCIMETRIQUE DE DIFFERENTS SYSTEMES D'INTRODUCTION D'ECHANTILLON NOUS A PERMIS D'OBSERVER LES MODIFICATIONS DE L'AEROSOL AU COURS DE SON TRANSPORT. POUR COMPLETER NOTRE ETUDE, NOUS AVONS TESTE L'INFLUENCE DE LA RESOLUTION DU MONOCHROMATEUR SUR LE RAPPORT SIGNAL SUR BRUIT. ENFIN, DANS LES CONDITIONS OPTIMALES, NOUS AVONS DETERMINE LES LIMITES DE DETECTION REELLES DE L'APPAREIL, DANS DES SOLUTIONS AQUEUSES ET DANS UNE SOLUTION DE TUNGSTENE A 10 G/L

DETERMINATION DES INTERFERENCES SPECTRALES EN SPECTROMETRIE D'EMISSION ATOMIQUE DE PLASMA INDUIT PAR HAUTE FREQUENCE EN VUE DE L'ANALYSE DES ELEMENTS TRACES ET MINEUR EN PRESENCE DE MAJEURS

Download DETERMINATION DES INTERFERENCES SPECTRALES EN SPECTROMETRIE D'EMISSION ATOMIQUE DE PLASMA INDUIT PAR HAUTE FREQUENCE EN VUE DE L'ANALYSE DES ELEMENTS TRACES ET MINEUR EN PRESENCE DE MAJEURS PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 184 pages
Book Rating : 4.:/5 (863 download)

DOWNLOAD NOW!


Book Synopsis DETERMINATION DES INTERFERENCES SPECTRALES EN SPECTROMETRIE D'EMISSION ATOMIQUE DE PLASMA INDUIT PAR HAUTE FREQUENCE EN VUE DE L'ANALYSE DES ELEMENTS TRACES ET MINEUR EN PRESENCE DE MAJEURS by : OLGA.. RODRIGUEZ-DIAZ

Download or read book DETERMINATION DES INTERFERENCES SPECTRALES EN SPECTROMETRIE D'EMISSION ATOMIQUE DE PLASMA INDUIT PAR HAUTE FREQUENCE EN VUE DE L'ANALYSE DES ELEMENTS TRACES ET MINEUR EN PRESENCE DE MAJEURS written by OLGA.. RODRIGUEZ-DIAZ and published by . This book was released on 1988 with total page 184 pages. Available in PDF, EPUB and Kindle. Book excerpt: ETUDE DES INTERFERENCES SPECTRALES SUR LES RAIES (604) LES PLUS SENSIBLES DE 21 ELEMENTS POUR 57 ELEMENTS INTERFERANTS A UNE CONCENTRATION DE 1 G/L. DETERMINATION DU TYPE D'INTERFERENCES, COINCIDENCE DE RAIES, RECOUVREMENT PARTIEL OU AUGMENTATION DU FOND. APPLICATION SUR UNE MATRICE TUNGSTENE

SPECTROMETRIE D'EMISSION A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE

Download SPECTROMETRIE D'EMISSION A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis SPECTROMETRIE D'EMISSION A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE by : MARIE-PIERRE.. SOUFFLET

Download or read book SPECTROMETRIE D'EMISSION A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE written by MARIE-PIERRE.. SOUFFLET and published by . This book was released on 1987 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Étude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge

Download Étude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 121 pages
Book Rating : 4.:/5 (247 download)

DOWNLOAD NOW!


Book Synopsis Étude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge by : Eric de Borniol

Download or read book Étude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge written by Eric de Borniol and published by . This book was released on 1999 with total page 121 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ETUDE DE L'ATMOSPHERE OU LE SUIVI DE PROCESSUS INDUSTRIELS NECESSITE DES INSTRUMENTS CAPABLES DE MESURER IN SITU ET DE FACON SELECTIVE DE FAIBLES CONCENTRATIONS DE GAZ. LA SPECTROMETRIE D'ABSORPTION PAR DIODE LASER INFRAROUGE REPOND A CE PROBLEME MAIS SA SENSIBILITE EST LIMITEE PAR LE BRUIT DE MESURE. LA PREMIERE PARTIE DE CE MEMOIRE EST CONSACREE A L'ETUDE DES BRUITS LIMITANT LA SENSIBILITE DES METHODES DE SPECTROSCOPIE UTILISANT DES DIODE LASER AUX SELS DE PLOMB, ET AUX DIFFERENTES TECHNIQUES MISES EN UVRE POUR L'AMELIORER. LES FLUCTUATIONS DE PUISSANCE DE LA DIODE LASER ETANT LE FACTEUR LE PLUS LIMITANT POUR LA SENSIBILITE, L'ETUDE DU BRUIT RELATIF D'INTENSITE (OU RIN) D'UNE TELLE SOURCE A ETE REALISEE. CETTE ETUDE MONTRE QUE CE BRUIT PEUT ETRE DIMINUE EN FONCTION DES CONDITIONS EXPERIMENTALES ET QU'IL PRESENTE, DANS TOUT LES CAS, UNE DECROISSANCE AVEC LA FREQUENCE D'ANALYSE (BRUIT EN 1/F). LA SECONDE PARTIE DU MEMOIRE EST DEDIEE A LA CONCEPTION ET A L'EVALUATION DE LA SENSIBILITE ULTIME D'UN SPECTROMETRE D'ABSORPTION DIFFERENTIELLE A BALAYAGE RAPIDE. LA LONGUEUR D'ONDE D'EMISSION EST BALAYEE PERIODIQUEMENT AUTOUR D'UNE RAIE D'ABSORPTION MOLECULAIRE EN MODULANT LE COURANT INJECTE DANS LA DIODE. DEUX VOIES OPTIQUES DE MESURE L'UNE TRAVERSANT LE MILIEU ET L'AUTRE NON SONT SOUSTRAITES L'UNE A L'AUTRE AVANT LA NUMERISATION DU SIGNAL. LE SIGNAL EST ENSUITE MOYENNE SUR PLUSIEURS PERIODES. L'ETUDE DU FILTRE RESULTANT DU BALAYAGE SPECTRAL RAPIDE MONTRE QUE LE BRUIT EN 1/F PEUT ETRE FILTRE EN DIMINUANT LA PERIODE DE MODULATION. LA SOUSTRACTION DE DEUX VOIES ASSOCIE A UNE COURTE PERIODE DE BALAYAGE (0,1 MS) PERMETTENT D'ATTEINDRE UNE TRES GRANDE SENSIBILITE. L'ANALYSE DE SPECTRES D'ABSORPTION DE LA MOLECULE DE CO VERS 2054 CM 1 MONTRE QUE LE SPECTROMETRE REALISE PERMET DE MESURER UNE ABSORPTION RELATIVE DE LA PUISSANCE LASER DE 1,1.10 6 EN 54,5 MS. SA SENSIBILITE LIMITE, CALCULEE POUR UNE BANDE PASSANTE DE 1 HZ EST DE 7.10 8. CETTE SENSIBILITE EST PROCHE DE CELLE OBTENUE PAR LA TECHNIQUE ACTUELLEMENT LA PLUS SENSIBLE TELLE QUE LA SPECTROSCOPIE DE MODULATION HAUTE FREQUENCE.

Etude de problèmes de filtrage de bruit de fond en spectrométrie nucléaire, amélioration du rapport signal sur bruit et des caractéristiques de l'impulsion mise en forme par le dispositif du prédicteur optimum

Download Etude de problèmes de filtrage de bruit de fond en spectrométrie nucléaire, amélioration du rapport signal sur bruit et des caractéristiques de l'impulsion mise en forme par le dispositif du prédicteur optimum PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 52 pages
Book Rating : 4.:/5 (251 download)

DOWNLOAD NOW!


Book Synopsis Etude de problèmes de filtrage de bruit de fond en spectrométrie nucléaire, amélioration du rapport signal sur bruit et des caractéristiques de l'impulsion mise en forme par le dispositif du prédicteur optimum by : Jerzy Benda

Download or read book Etude de problèmes de filtrage de bruit de fond en spectrométrie nucléaire, amélioration du rapport signal sur bruit et des caractéristiques de l'impulsion mise en forme par le dispositif du prédicteur optimum written by Jerzy Benda and published by . This book was released on 1967 with total page 52 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Étude et réalisation d'un spectromètre de masse équipé d'une source d'ions à excitation électrique de haute fréquence

Download Étude et réalisation d'un spectromètre de masse équipé d'une source d'ions à excitation électrique de haute fréquence PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 72 pages
Book Rating : 4.:/5 (494 download)

DOWNLOAD NOW!


Book Synopsis Étude et réalisation d'un spectromètre de masse équipé d'une source d'ions à excitation électrique de haute fréquence by : Jocelyn Garcia

Download or read book Étude et réalisation d'un spectromètre de masse équipé d'une source d'ions à excitation électrique de haute fréquence written by Jocelyn Garcia and published by . This book was released on 1966 with total page 72 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Etude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge

Download Etude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 121 pages
Book Rating : 4.:/5 (247 download)

DOWNLOAD NOW!


Book Synopsis Etude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge by : Eric de Borniol

Download or read book Etude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge written by Eric de Borniol and published by . This book was released on 1999 with total page 121 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ETUDE DE L'ATMOSPHERE OU LE SUIVI DE PROCESSUS INDUSTRIELS NECESSITE DES INSTRUMENTS CAPABLES DE MESURER IN SITU ET DE FACON SELECTIVE DE FAIBLES CONCENTRATIONS DE GAZ. LA SPECTROMETRIE D'ABSORPTION PAR DIODE LASER INFRAROUGE REPOND A CE PROBLEME MAIS SA SENSIBILITE EST LIMITEE PAR LE BRUIT DE MESURE. LA PREMIERE PARTIE DE CE MEMOIRE EST CONSACREE A L'ETUDE DES BRUITS LIMITANT LA SENSIBILITE DES METHODES DE SPECTROSCOPIE UTILISANT DES DIODE LASER AUX SELS DE PLOMB, ET AUX DIFFERENTES TECHNIQUES MISES EN UVRE POUR L'AMELIORER. LES FLUCTUATIONS DE PUISSANCE DE LA DIODE LASER ETANT LE FACTEUR LE PLUS LIMITANT POUR LA SENSIBILITE, L'ETUDE DU BRUIT RELATIF D'INTENSITE (OU RIN) D'UNE TELLE SOURCE A ETE REALISEE. CETTE ETUDE MONTRE QUE CE BRUIT PEUT ETRE DIMINUE EN FONCTION DES CONDITIONS EXPERIMENTALES ET QU'IL PRESENTE, DANS TOUT LES CAS, UNE DECROISSANCE AVEC LA FREQUENCE D'ANALYSE (BRUIT EN 1/F). LA SECONDE PARTIE DU MEMOIRE EST DEDIEE A LA CONCEPTION ET A L'EVALUATION DE LA SENSIBILITE ULTIME D'UN SPECTROMETRE D'ABSORPTION DIFFERENTIELLE A BALAYAGE RAPIDE. LA LONGUEUR D'ONDE D'EMISSION EST BALAYEE PERIODIQUEMENT AUTOUR D'UNE RAIE D'ABSORPTION MOLECULAIRE EN MODULANT LE COURANT INJECTE DANS LA DIODE. DEUX VOIES OPTIQUES DE MESURE L'UNE TRAVERSANT LE MILIEU ET L'AUTRE NON SONT SOUSTRAITES L'UNE A L'AUTRE AVANT LA NUMERISATION DU SIGNAL. LE SIGNAL EST ENSUITE MOYENNE SUR PLUSIEURS PERIODES. L'ETUDE DU FILTRE RESULTANT DU BALAYAGE SPECTRAL RAPIDE MONTRE QUE LE BRUIT EN 1/F PEUT ETRE FILTRE EN DIMINUANT LA PERIODE DE MODULATION. LA SOUSTRACTION DE DEUX VOIES ASSOCIE A UNE COURTE PERIODE DE BALAYAGE (0,1 MS) PERMETTENT D'ATTEINDRE UNE TRES GRANDE SENSIBILITE. L'ANALYSE DE SPECTRES D'ABSORPTION DE LA MOLECULE DE CO VERS 2054 CM 1 MONTRE QUE LE SPECTROMETRE REALISE PERMET DE MESURER UNE ABSORPTION RELATIVE DE LA PUISSANCE LASER DE 1,1.10 6 EN 54,5 MS. SA SENSIBILITE LIMITE, CALCULEE POUR UNE BANDE PASSANTE DE 1 HZ EST DE 7.10 8. CETTE SENSIBILITE EST PROCHE DE CELLE OBTENUE PAR LA TECHNIQUE ACTUELLEMENT LA PLUS SENSIBLE TELLE QUE LA SPECTROSCOPIE DE MODULATION HAUTE FREQUENCE.