Advantages of Using the ANSI/ASHRAE 110-1995 Tracer Gas Test Method Vs. the ANSI/AIHA Z9.5-1992 Face Velocity Test Method for the Chemical Laboratory Hood Certification

Download Advantages of Using the ANSI/ASHRAE 110-1995 Tracer Gas Test Method Vs. the ANSI/AIHA Z9.5-1992 Face Velocity Test Method for the Chemical Laboratory Hood Certification PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (173 download)

DOWNLOAD NOW!


Book Synopsis Advantages of Using the ANSI/ASHRAE 110-1995 Tracer Gas Test Method Vs. the ANSI/AIHA Z9.5-1992 Face Velocity Test Method for the Chemical Laboratory Hood Certification by :

Download or read book Advantages of Using the ANSI/ASHRAE 110-1995 Tracer Gas Test Method Vs. the ANSI/AIHA Z9.5-1992 Face Velocity Test Method for the Chemical Laboratory Hood Certification written by and published by . This book was released on 2006 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: A total of 484 tests were performed on chemical laboratory hoods (chemical hoods), using the ANSI/AIHA Z9.5-1992 (American National Standard Institute / American Industrial Hygiene Association, Laboratory Ventilation Standard) test method (ANSI-1992). Same numbers of the tests were performed on same chemical hoods, using the ANSI/ASHRAE 110-1995 (American National Standards Institute/American Society of Heating, Refrigerating, and Air Conditioning Engineers, Method of Testing Performance of Laboratory Fume Hoods) test method (ASHRAE 110). The three types of chemical hoods available for this study were Constant Air Volume (CAV), Variable Air Volume (VAV), and Low Flow. Overall, CAV hoods had the highest passing rate for the ASHRAE 110 (83%) followed by VAV hoods (82%) and low flow hoods (68%). The X2 test for homogeneity found a statistically significant difference between the test outcomes (pass/fail) of the ASHRAE 110 and the ANSI-1992 methods (X2 = 4.248, P=0.038) for VAV hoods only. Overall, 18% of the CAV and VAV chemical hoods tested in the 80-120 feet per minute (fpm) average face velocities, failed to meet the ASHRAE 110 test criteria. If the ANSI-1992 test method was performed alone, 18% of the chemical hoods would be certified while they were not able to meet the ASHRAE 110 criteria. Logistic regression analysis for VAV and CAV chemical hoods revealed that for VAV chemical hoods, the ASHRAE = Velocity model and for CAV chemical hoods, the multi variable regression model ASHRAE = ANSI + Velocity were appeared to be the best model for the ASHRAE 110 test outcome prediction.

ANSI/ASHRAE standard 110-1995

Download ANSI/ASHRAE standard 110-1995 PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (14 download)

DOWNLOAD NOW!


Book Synopsis ANSI/ASHRAE standard 110-1995 by :

Download or read book ANSI/ASHRAE standard 110-1995 written by and published by . This book was released on 1995 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

ANSI/ASHRAE Standard 140-2023

Download ANSI/ASHRAE Standard 140-2023 PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (142 download)

DOWNLOAD NOW!


Book Synopsis ANSI/ASHRAE Standard 140-2023 by : ASHRAE.

Download or read book ANSI/ASHRAE Standard 140-2023 written by ASHRAE. and published by . This book was released on 2023 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: DescripciĆ³n del editor : "Standard 140 specifies a method of test for evaluating the technical capabilities and applicability of software used in calculating the thermal performance of buildings and their HVAC systems. These test procedures can be used to identify and diagnose predictive differences from building performance simulation software that may be caused by algorithmic differences, modeling limitations, faulty coding, inadequate documentation, or input errors; the procedures can also be used to evaluate the acceptability of software.The current set of tests focuses on building thermal envelope and fabric loads and HVAC equipment performance, and includes:* Comparative tests, in which a program's results may be compared to a different version of itself or to the results of other programs;* Analytical verification tests, in which a program's results may be compared to analytical, quasi-analytical, or verified numerical model solutions.This procedure tests software over a broad range of parametric interactions and for a number of different output types, thus minimizing the concealment of algorithmic differences by compensating errors. Different building performance simulation programs, representing different degrees of modeling complexity, can be tested. However, some of the tests may be incompatible with some building performance simulation programs.The revised 2023 edition of Standard 140 includes all the test cases of Standard 140-2020 and adds a new test suite that evaluates a software's ability to read and interpret standard format weather data." (Ashrae).