Design, Fabrication and Testing of a High Precision Air Amplifier as an Ion Focusing Device for Mass Spectrometry

Download Design, Fabrication and Testing of a High Precision Air Amplifier as an Ion Focusing Device for Mass Spectrometry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 87 pages
Book Rating : 4.:/5 (747 download)

DOWNLOAD NOW!


Book Synopsis Design, Fabrication and Testing of a High Precision Air Amplifier as an Ion Focusing Device for Mass Spectrometry by : Guillaume Robichaud

Download or read book Design, Fabrication and Testing of a High Precision Air Amplifier as an Ion Focusing Device for Mass Spectrometry written by Guillaume Robichaud and published by . This book was released on 2011 with total page 87 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Development and Application of an Electrospray Ionization Ion Mobility-mass Spectrometer Using an RF Ion Funnel and Periodic-focusing Ion Guide

Download Development and Application of an Electrospray Ionization Ion Mobility-mass Spectrometer Using an RF Ion Funnel and Periodic-focusing Ion Guide PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (881 download)

DOWNLOAD NOW!


Book Synopsis Development and Application of an Electrospray Ionization Ion Mobility-mass Spectrometer Using an RF Ion Funnel and Periodic-focusing Ion Guide by : Junho Jeon

Download or read book Development and Application of an Electrospray Ionization Ion Mobility-mass Spectrometer Using an RF Ion Funnel and Periodic-focusing Ion Guide written by Junho Jeon and published by . This book was released on 2014 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: A novel ion mobility-mass spectrometer was designed and built in order to achieve high transmission and high resolution for observing desolvated ion conformations of chemical and biological molecules in the gas phase. The instrument incorporates a home-built electrospray ionization (ESI) source and rf ion funnel(IF) as an ion transfer interface, modular periodic-focusing ion guide (PFIG) as a drift tube (DT) for arrival time measurement, and orthogonally accelerated linear time-of-flight mass spectrometer to maximize analytical figures-of-merit of the instrument including sensitivity and separation of gas-phase ions. The rationales for implementation of each device aforementioned are discussed as enhanced ion focusing to reduce data acquisition time of the instrument, high mobility resolution (R > 56) to separate ions having a small collision cross section (CCS) difference at low-to-intermediate field strength (10 V cm−1 torr−1~19 V cm−1 torr−1), and observation of multiple conformers from isobaric ions at various operation conditions. Gate and transfer ion optic design needed to avoid detrimental gas dynamic effect is presented during hybridization of PFIG into ESI mass spectrometer. The details of instrumentation and electrode/voltage schematics are also discussed along with SIMION calculation results. The characteristic drift motions of ions inside the PFIG require a normalization procedure to compare CCS values from the instrument with the results using conventional uniform field DT ion mobility-mass spectrometry (IM-MS). Through experimental measurements and ion trajectory calculations from well known model peptides and proteins having multiple charge states, a correlation factor a which links the results from the two different types of instrumentation was derived and successfully applied (within ±4% difference). Ion heating was also investigated using ubiquitin, insulin, and substance P. Using ESI PFIG-MS, a significant variation of the arrival time distribution at different heated capillary temperature, rf amplitude, and electric field strength was observed for ubiquitin (+7) and (+8) and substance P (+3), while a substantial change was not observed for insulin owing to structural rigidity of disulfide bond cross-linking between two chains. The results imply that ESI PFIG-MS provides a window to monitor conformational variation of gas-phase ions and measure energy barriers of peptide/protein folding processes, which can allow us to reveal pathways in structural energy landscape. The electronic version of this dissertation is accessible from http://hdl.handle.net/1969.1/151673

A Feasibility Study of Ion Implantation Techniques for Mass Spectrometer Calibration

Download A Feasibility Study of Ion Implantation Techniques for Mass Spectrometer Calibration PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 28 pages
Book Rating : 4.:/5 (317 download)

DOWNLOAD NOW!


Book Synopsis A Feasibility Study of Ion Implantation Techniques for Mass Spectrometer Calibration by :

Download or read book A Feasibility Study of Ion Implantation Techniques for Mass Spectrometer Calibration written by and published by . This book was released on 1978 with total page 28 pages. Available in PDF, EPUB and Kindle. Book excerpt: An experimental study was undertaken to examine the feasibility of using ion-implanted filaments doped with either an alkali metal or noble gas for in situ recalibration of onboard mass spectrometers during extended space missions. Implants of rubidium and krypton in rhenium ribbon filaments were subsequently tested in a bakeable 60 deg sector mass spectrometer operating in the static mode. Surface ionization and electron impact ion sources were both used, each yielding satisfactory results. The metallic implant with subsequent ionization provided a means of mass scale calibration and determination of system operating parameters, whereas the noble gas thermally desorbed into the system was more suited for partial pressure and sensitivity determinations.

The Use of Capacitive Transimpedance Amplifier Array Detectors for Mass Spectrometry

Download The Use of Capacitive Transimpedance Amplifier Array Detectors for Mass Spectrometry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 532 pages
Book Rating : 4.:/5 (78 download)

DOWNLOAD NOW!


Book Synopsis The Use of Capacitive Transimpedance Amplifier Array Detectors for Mass Spectrometry by : Christopher Andrew Zarzana

Download or read book The Use of Capacitive Transimpedance Amplifier Array Detectors for Mass Spectrometry written by Christopher Andrew Zarzana and published by . This book was released on 2011 with total page 532 pages. Available in PDF, EPUB and Kindle. Book excerpt: Mass spectrometry is a powerful tool in the field of analytical chemistry. Though there have been numerous advances in mass analyzer technology over the decades, there has been comparatively little advancement in mass spectrometer detector technology. The development of the scientific charged-coupled device over 30 years ago brought the advantages of simultaneous detection over single channel detection to optical spectroscopy, including higher signal-to-noise ratios for a fixed analysis time, shorter analysis time to obtain a given signal-to-noise ratio, and greater sample throughput. While the use of array detectors to achieve simultaneous detection is commonplace in optical spectroscopy, ion detectors for mass spectrometry have lagged behind. Over the last decade, a new type of ion detector, the capacitive transimpedance amplifier (CTIA) array detector, has been developed that has a number of properties that make it an excellent tool for simultaneous detection using dispersive mass spectrometers. The CTIA array detector has high sensitivity as well as high gain stability, allowing it to excel in applications that require high precision measurements of ion signals, such as isotope ratio mass spectrometry. Capacitive transimpedance amplifier array detectors have previously been used to demonstrate the power of simultaneous detection on Mattauch-Herzog double focusing mass spectrometers, but the non-linear mass dispersion of these instruments means that the resolution is not constant across the array. A different type of dispersive instrument, the linear cycloid, has a linear mass dispersion, making it a good candidate for an array detector. The first detailed characterization of gain, read noise and dark-current noise, as well as of operating behavior over a range of temperatures, of the DM0025, a 1696 pixel CTIA array detector was performed. In addition, the first-ever combination of a CTIA array detector with a linear cycloid mass spectrometer was developed. This combined instrument demonstrated simultaneous detection of multiple masses, as well as a linear mass range. The results from the detailed characterization of the detector were used in conjunction with measurements of the performance of the combined instrument to suggest improvements for the next generation of linear cycloid instruments with CTIA array detectors.

Scientific and Technical Aerospace Reports

Download Scientific and Technical Aerospace Reports PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 704 pages
Book Rating : 4.:/5 (31 download)

DOWNLOAD NOW!


Book Synopsis Scientific and Technical Aerospace Reports by :

Download or read book Scientific and Technical Aerospace Reports written by and published by . This book was released on 1995 with total page 704 pages. Available in PDF, EPUB and Kindle. Book excerpt:

A Solid State Direct-current Amplifier System for Mass Spectrometry

Download A Solid State Direct-current Amplifier System for Mass Spectrometry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 18 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis A Solid State Direct-current Amplifier System for Mass Spectrometry by : Clint Sulfridge

Download or read book A Solid State Direct-current Amplifier System for Mass Spectrometry written by Clint Sulfridge and published by . This book was released on 1969 with total page 18 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Development of an Ion Mass Spectrometer and Sounding Rocket System for D-region Cluster-ion Measurement

Download Development of an Ion Mass Spectrometer and Sounding Rocket System for D-region Cluster-ion Measurement PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 108 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Development of an Ion Mass Spectrometer and Sounding Rocket System for D-region Cluster-ion Measurement by : A. Bailey

Download or read book Development of an Ion Mass Spectrometer and Sounding Rocket System for D-region Cluster-ion Measurement written by A. Bailey and published by . This book was released on 1982 with total page 108 pages. Available in PDF, EPUB and Kindle. Book excerpt: An Ion Mass Spectrometer and supporting Sounding Rocket System were developed to make in situ measurements of cluster-ions in the D-region of the ionosphere. A cryogenically vacuum-pumped quadrupole mass filter and secondary emission ion counter are coupled to make mass spectral measurements of positive and negative ion composition in ambient gas sampled at the apex of a cone designed to attach the shock wave induced by supersonic sounding rocket speeds. (Author).

Design Fabrication and Testing of RF Power Amplifier

Download Design Fabrication and Testing of RF Power Amplifier PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 106 pages
Book Rating : 4.:/5 (231 download)

DOWNLOAD NOW!


Book Synopsis Design Fabrication and Testing of RF Power Amplifier by : Parthasarathi Datta

Download or read book Design Fabrication and Testing of RF Power Amplifier written by Parthasarathi Datta and published by . This book was released on 2007 with total page 106 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Lunar Surface Studies

Download Lunar Surface Studies PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 534 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Lunar Surface Studies by :

Download or read book Lunar Surface Studies written by and published by . This book was released on 1962 with total page 534 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Ion Source for High-precision Mass Spectrometry

Download Ion Source for High-precision Mass Spectrometry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (873 download)

DOWNLOAD NOW!


Book Synopsis Ion Source for High-precision Mass Spectrometry by :

Download or read book Ion Source for High-precision Mass Spectrometry written by and published by . This book was released on 1984 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The invention is directed to a method for increasing the precision of positive-ion relative abundance measurements conducted in a sector mass spectrometer having an ion source for directing a beam of positive ions onto a collimating slit. The method comprises incorporating in the source an electrostatic lens assembly for providing a positive-ion beam of circular cross section for collimation by the slit.

Mass Spectrometry

Download Mass Spectrometry PDF Online Free

Author :
Publisher : Wiley
ISBN 13 : 9780471485650
Total Pages : 420 pages
Book Rating : 4.4/5 (856 download)

DOWNLOAD NOW!


Book Synopsis Mass Spectrometry by : Edmond de Hoffmann

Download or read book Mass Spectrometry written by Edmond de Hoffmann and published by Wiley. This book was released on 2001-10-10 with total page 420 pages. Available in PDF, EPUB and Kindle. Book excerpt: Offers a complete overview of the principles, theories and key applications of modern mass spectrometry in this introductory textbook. Following on from the highly successful first edition, this edition is extensively updated including new techniques and applications. All instrumental aspects of mass spectrometry are clearly and concisely described; sources, analysers and detectors. * Revised and updated * Numerous examples and illustrations are combined with a series of exercises to help encourage student understanding * Includes biological applications, which have been significantly expanded and updated * Also includes coverage of ESI and MALDI

Design and Fabrication of a High Performance, Low Cost Biological Amplifier

Download Design and Fabrication of a High Performance, Low Cost Biological Amplifier PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 92 pages
Book Rating : 4.:/5 (216 download)

DOWNLOAD NOW!


Book Synopsis Design and Fabrication of a High Performance, Low Cost Biological Amplifier by : Andrew Y. J. Szeto

Download or read book Design and Fabrication of a High Performance, Low Cost Biological Amplifier written by Andrew Y. J. Szeto and published by . This book was released on 1974 with total page 92 pages. Available in PDF, EPUB and Kindle. Book excerpt:

U.S. Government Research Reports

Download U.S. Government Research Reports PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 426 pages
Book Rating : 4.3/5 (243 download)

DOWNLOAD NOW!


Book Synopsis U.S. Government Research Reports by :

Download or read book U.S. Government Research Reports written by and published by . This book was released on 1962 with total page 426 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Technical Abstract Bulletin

Download Technical Abstract Bulletin PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 824 pages
Book Rating : 4.:/5 (5 download)

DOWNLOAD NOW!


Book Synopsis Technical Abstract Bulletin by : Defense Documentation Center (U.S.)

Download or read book Technical Abstract Bulletin written by Defense Documentation Center (U.S.) and published by . This book was released on 1963 with total page 824 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Nuclear Science Abstracts

Download Nuclear Science Abstracts PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 516 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Nuclear Science Abstracts by :

Download or read book Nuclear Science Abstracts written by and published by . This book was released on 1973 with total page 516 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Design, Fabrication and Testing of a Crossed Field Amplifier for Use in the Solar Power Satellite

Download Design, Fabrication and Testing of a Crossed Field Amplifier for Use in the Solar Power Satellite PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 280 pages
Book Rating : 4.:/5 (225 download)

DOWNLOAD NOW!


Book Synopsis Design, Fabrication and Testing of a Crossed Field Amplifier for Use in the Solar Power Satellite by : William C. Brown

Download or read book Design, Fabrication and Testing of a Crossed Field Amplifier for Use in the Solar Power Satellite written by William C. Brown and published by . This book was released on 1978 with total page 280 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Mass Spectrometry

Download Mass Spectrometry PDF Online Free

Author :
Publisher : Springer Science & Business Media
ISBN 13 : 3540407391
Total Pages : 534 pages
Book Rating : 4.5/5 (44 download)

DOWNLOAD NOW!


Book Synopsis Mass Spectrometry by : Jürgen H Gross

Download or read book Mass Spectrometry written by Jürgen H Gross and published by Springer Science & Business Media. This book was released on 2006-04-05 with total page 534 pages. Available in PDF, EPUB and Kindle. Book excerpt: Mass Spectrometry is an ideal textbook for students and professionals as well as newcomers to the field. Starting from the very first principles of gas-phase ion chemistry and isotopic properties, the textbook takes the reader through the design of mass analyzers and ionization methods all the way to mass spectral interpretation and coupling techniques. Step-by-step, the reader learns how mass spectrometry works and what it can do. The book comprises a balanced mixture of practice-oriented information and theoretical background. It features a clear layout and a wealth of high-quality figures. Exercises and solutions are located on the Springer Global Web.