Accuracy of Implant Casts Generated with Conventional and Digital Impressions U2013 An in Vitro Study

Download Accuracy of Implant Casts Generated with Conventional and Digital Impressions U2013 An in Vitro Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (116 download)

DOWNLOAD NOW!


Book Synopsis Accuracy of Implant Casts Generated with Conventional and Digital Impressions U2013 An in Vitro Study by : A. Ribeiro Paulo

Download or read book Accuracy of Implant Casts Generated with Conventional and Digital Impressions U2013 An in Vitro Study written by A. Ribeiro Paulo and published by . This book was released on 2017 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Introduction: Studies demonstrated that the accuracy of intra-oral scanners can be compared with conventional impressions for most indications. However, little is known about their applicability to take impressions of multiple implants.Objective: compare the accuracy between digital impressions and different conventional printing techniques in implants in order to observe differences of the novel digital impression with the conventional techniques.Material and Methods: A stone cast of an edentulous mandible with 4 implants was fabricated to serve as master cast (control), two master models were made: one with parallel implants (Model 1)and another with uneven implants(Model 2). Model 1: 4 types of impressions were taken(Group A: tray impressions with reposition abutments; Group B: Open tray impression groups for dragging copings, without splinting; Group C: Open tray impressions for ferrules; Group D: Using 3M u2122 True Definition Scanner system).Model 2: 3 types of impressions were taken(Group E: tray impressions with reposition abutments; Group F: Open tray impression groups for dragging copings, without splinting; Group G: Using 3M u2122 True Definition Scanner system).Master casts and conventional impression casts were digitized with na extraoral high-resolution scanner. Standard tessellation language (STL)data sets from the seven groups of digital and conventional impressions were superimposed with the STL data set from the master cast to assess the 3D (global)deviations. To compare the master cast with digital and conventional impressions.Results: Statistical analysis was performed using the IBMu00ae SPSSu00ae Statistics Vs. 24, NY, USA.The normality of the distributions was analysed with an Kolmogorov-Smirnov test. The median comparison was performed using The differences between the median were analyzed using non-parametric Krustal-Wallis and Mann-Whitney tests with a significance level of p

Accuracy of Digital and Conventional Implant Impressions

Download Accuracy of Digital and Conventional Implant Impressions PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (116 download)

DOWNLOAD NOW!


Book Synopsis Accuracy of Digital and Conventional Implant Impressions by : Bohner Lauren

Download or read book Accuracy of Digital and Conventional Implant Impressions written by Bohner Lauren and published by . This book was released on 2017 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: In order to ensure a correct occlusion and fit of restorations, the accuracy of entire arch is required. In these cases, the quality of the dental cast relies on the digitizing and machining processes provided by CAD-CAM systems. As geometric errors may be introduced during the step of scanning and manufacturing of casts, their accuracy is still questionable.The purpose of this study was to compare the accuracy of casts obtained using digital and conventional implant impressions. A maxillary model containing dentalimplants on the region of canine and pre-molar was used as master model. Dental casts (n=10) were fabricated through both conventional and digital implant impressions. The conventional casts (CC), stereolithographic casts (SC) and the master model (MM) were digitized and the accuracy was determined through a deviation analysis and linear measurements. Data were analyzed using Student t-test and ANOVA with p=0.05. SC showed higher deviation at vestibular (CC: 41 u00b1 28; SC: 117 u00b1 37 u03bcm) and lingual cusps (CC: 40 u00b1 19; SC: 80 u00b1 42 u03bcm) in comparison to CC. No statistically significant difference was found for linear measurements of conventional and digital casts. The entire-arch accuracy was comparable between casts. However, in located points, stereolithographic casts were less accurate in comparison with conventional casts.

Implant Restorations

Download Implant Restorations PDF Online Free

Author :
Publisher : John Wiley & Sons
ISBN 13 : 1118828844
Total Pages : 389 pages
Book Rating : 4.1/5 (188 download)

DOWNLOAD NOW!


Book Synopsis Implant Restorations by : Carl Drago

Download or read book Implant Restorations written by Carl Drago and published by John Wiley & Sons. This book was released on 2014-02-06 with total page 389 pages. Available in PDF, EPUB and Kindle. Book excerpt: Implant Restorations: A Step-by-Step Guide, Third Edition offers clinicians a practical, step-by-step approach to treatment planning and restoring dental implants. This highly illustrated, case-based book demonstrates how to treat the most commonly encountered treatment scenarios, describing the procedures, techniques, and sequences required in clear, concise language and in an easy-to-use format. The book takes the theory of implant restoration, using as its basis 3i’s implant systems, and places it directly in the operatory, concentrating in detail on each stage of the actual clinical procedures involved in treating different patients. It integrates implant treatment with the realities of running a successful restorative practice. Building on the work of the 2nd edition, the 3rd edition of this successful text reflects the advances of implant prosthetics over the intervening years, providing all new cases, exploring new techniques and technology, and demonstrating updated system components and armamentarium. Implant Restorations: A Step-by-Step Guide follows a logical structure of three sections. The first section introduces implant restorative dentistry, how to develop an implant restorative practice, the issues involved, the technical components of the 3i systems, diagnosis, and treatment planning. The central section of the book devotes separate chapters to in-depth descriptions of each of several types of patients that the restorative dentist may encounter, ranging from basic to more challenging cases. Every step of each procedure is described and illustrated with clinical photographs. Laboratory work orders are presented for use with commercial dental laboratories. The final section discusses record-keeping, patient compliance, hygiene regimes and follow-up, and provides the reader with an outline of best-practice procedural protocols. An excellent and accessible guide on the most burgeoning subject in modern dental practice by one of its most experienced clinicians, Implant Restorations: A Step-by-Step Guide, Third Edition will appeal to prosthodontists, general dentists, implant surgeons, dental students, dental laboratory technicians and dental assistants.

Accuracy of Computerized and Conventional Impression-making Procedures of Straight and Tilted Dental Implants

Download Accuracy of Computerized and Conventional Impression-making Procedures of Straight and Tilted Dental Implants PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (944 download)

DOWNLOAD NOW!


Book Synopsis Accuracy of Computerized and Conventional Impression-making Procedures of Straight and Tilted Dental Implants by : Aiste Gintaute

Download or read book Accuracy of Computerized and Conventional Impression-making Procedures of Straight and Tilted Dental Implants written by Aiste Gintaute and published by . This book was released on 2016 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Accuracy of Full Digital Workflow for Dental Implants Insertion in Partially Edentulous Patients

Download Accuracy of Full Digital Workflow for Dental Implants Insertion in Partially Edentulous Patients PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (116 download)

DOWNLOAD NOW!


Book Synopsis Accuracy of Full Digital Workflow for Dental Implants Insertion in Partially Edentulous Patients by : Burlibasa M

Download or read book Accuracy of Full Digital Workflow for Dental Implants Insertion in Partially Edentulous Patients written by Burlibasa M and published by . This book was released on 2017 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Background: Static computer-aided implant surgery is a predictable and widely accepted procedure, its accuracy being within the clinical acceptable range in the majority of clinical situations. Usually the 3D model of the bone and surrounding structures is obtained via cone beam computed tomography (CBCT) and the patientu2019s oral condition can be acquired conventionally and then digitalized using a desktop scanner - partially digital workflow (DW) or digitally with the aid of an intraoral scanner - full DW.The aim of the present pilot study is to compare the accuracy of a full digital workflow to partially digital workflow for a limited edentulous space (1 to 3 dental units) using an inspection tool software. Null hypothesis tested: full digital WF is more accurate comparing to partially DW.Materials and methods: The study was conducted in accordance with ethical principles including the World Medical Association Declaration of Helsinki, approved by the University Bioethical Committee, registered (ClinicalTrials.gov Identifier: NCT03814655) and written consent of each subject was obtained.Patients with Kennedy Class III partially edentulism, good general health, acceptance of dental implant treatment, acceptance of pre-operative CBCT, not requiring bone graft, not limited mouth opening were included.The full DW included: intraoral scan of the partially edentulous site, antagonists and occlusion registration, CBCT with radiopaque customized tray placed over the partially edentulous arch; merging files in R2 Gate planning software (Megagen, Korea), implant placement and digital scanning of implants position (.stl u2013 Stereolithography file).In the partially DW, digital impression was replaced with a conventional impression and poured casts are scanned with a desktop scanner.Results: 20 patients were enrolled in this prospective, pilot study and 38 implants were inserted using tooth-supported surgical templates and a flapless technique. Neither complications nor unexpected events occurred during implants insertion.22 implants were inserted using full DW. Inserted and planned implant position were compared using Geomagic Qualify 2013 software (3D Systems,USA).The mean 3D errors of implant positioning for the two insertion protocols were: 0.62mm (u00b10.42) entry point, 0.98mm (u00b10.73) at the implant apex, 2.1 (u00b10.35) angular deviation for full DW, respectively 0.68(u00b10.57), 1.02mm (u00b10.43) and 2.4 (u00b10.22) for partially DW. The t test for implant position showed no statistically significant differences (p > .05) in accuracy between full DW and partially DW, rejecting the null hypothesis tested.Conclusions and clinical implications: Within the limits of the present pilot study, the surgical template used has proved high accuracy for implant insertion, both in full and partially DW.The results of this study suggest that a full digital workflow for computer-guided implant surgery in partially edentulous patients is a reliable method and could be used in clinical situations.

Loading Protocols in Implant Dentistry

Download Loading Protocols in Implant Dentistry PDF Online Free

Author :
Publisher : Quintessenz Verlag
ISBN 13 : 1850973458
Total Pages : 345 pages
Book Rating : 4.8/5 (59 download)

DOWNLOAD NOW!


Book Synopsis Loading Protocols in Implant Dentistry by : Daniel Wismeijer

Download or read book Loading Protocols in Implant Dentistry written by Daniel Wismeijer and published by Quintessenz Verlag. This book was released on 2019-09-03 with total page 345 pages. Available in PDF, EPUB and Kindle. Book excerpt: Implant dentistry has become a standard option for the rehabilitation of fully and partially edentulous patients. With the ever-increasing number of dentists involved in implant dentistry, it is essential to ensure that their treatment methods follow the highest standard. The ITI Treatment Guide series, a compendium of evidence-based implant-therapy techniques in daily practice, is written by renowned clinicians and provides a comprehensive overview of various therapeutic options. Using an illustrated step-by-step approach, the ITI Treatment Guide shows practitioners how to manage different clinical situations, with the emphasis on sound diagnostics, evidence-based treatment concepts, and predictable treatment outcomes. The second volume of the ITI Treatment Guide is devoted to the restoration of partially dentate patients. Central to this volume of the ITI Treatment Guide are loading protocols available to the clinician and the patient and how they relate to various treatment indications, including both single and multiple missing teeth in the posterior and anterior regions of the mouth. Among potential topics for upcoming volumes are implant placement in extraction sockets, loading protocols in edentulous patients, implant therapy in the esthetic zone in extended edentulous spaces, and many more.

Implants in the Aesthetic Zone

Download Implants in the Aesthetic Zone PDF Online Free

Author :
Publisher : Springer
ISBN 13 : 3319726013
Total Pages : 335 pages
Book Rating : 4.3/5 (197 download)

DOWNLOAD NOW!


Book Synopsis Implants in the Aesthetic Zone by : Todd R. Schoenbaum

Download or read book Implants in the Aesthetic Zone written by Todd R. Schoenbaum and published by Springer. This book was released on 2018-11-19 with total page 335 pages. Available in PDF, EPUB and Kindle. Book excerpt: This book concisely elucidates the science underlying implant treatment in the aesthetic zone in partially edentulous patients and clearly describes the techniques and protocols used by world-leading experts in the field. The book is divided into four parts that address treatment planning; site preparation (hard and soft tissue augmentation); immediate implant placement and provisional restoration; and the design, fabrication, and delivery of the definitive implant prosthesis. Complex cases of this nature present a significant challenge to even the most well informed and experienced of doctors. Implants in the Aesthetic Zone has been specifically crafted to meet all the needs of the clinician involved in their management, providing a reliable road map for interdisciplinary implant treatment in clinical practice. The authors have been carefully selected from a wide range of fields for their expertise in particular areas of implant science or treatment.

Evaluation of Digital Implant Impressions Using an Intra-oral Computerized Scanner (iTero) Versus Conventional Implant Impressions

Download Evaluation of Digital Implant Impressions Using an Intra-oral Computerized Scanner (iTero) Versus Conventional Implant Impressions PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (13 download)

DOWNLOAD NOW!


Book Synopsis Evaluation of Digital Implant Impressions Using an Intra-oral Computerized Scanner (iTero) Versus Conventional Implant Impressions by : G. Kinga Baskai

Download or read book Evaluation of Digital Implant Impressions Using an Intra-oral Computerized Scanner (iTero) Versus Conventional Implant Impressions written by G. Kinga Baskai and published by . This book was released on 2014 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Accuracy of the Biomet 3i Encode® Robocast TM Technology Versus Conventional Implant Impression Techniques

Download Accuracy of the Biomet 3i Encode® Robocast TM Technology Versus Conventional Implant Impression Techniques PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 41 pages
Book Rating : 4.:/5 (743 download)

DOWNLOAD NOW!


Book Synopsis Accuracy of the Biomet 3i Encode® Robocast TM Technology Versus Conventional Implant Impression Techniques by : Kent Jon Howell

Download or read book Accuracy of the Biomet 3i Encode® Robocast TM Technology Versus Conventional Implant Impression Techniques written by Kent Jon Howell and published by . This book was released on 2011 with total page 41 pages. Available in PDF, EPUB and Kindle. Book excerpt: Abstract: Accuracy of implant master casts and the subsequent fit of implant restorations is an important and challenging factor for the implant restorative dentist. This study compared the accuracy of master casts referred to as a Robocast TM (Biomet 3i, West Palm Beach, FL), that contained implant analogs fabricated by means of a CADCAM technology known as the Encode® Impression System (Biomet 3i, West Palm Beach, FL). The Robocasts were compared to master casts fabricated with traditional implant impression techniques: transfer (closed-tray) and pick-up (open-tray) impression methods. Specifically, results were compared in parallel versus non-parallel implants, as well as individual implant sites. A stereolithographic replica of a human mandible, with teeth numbers 21-28 present, was fabricated. Posterior segments were edentulous. Four 4.0 x 10mm Biomet 3i Full Osseotite® Certain implants (Biomet 3i, West Palm Beach, FL) were placed in the posterior, 2 on each side; implants on one side were parallel to each other; implants on the other side diverged in the vertical plane by 30 degrees. Polyvinyl siloxane (PVS) impressions were made with CADCAM healing abutments, pick-up and transfer impression copings. Impression procedures were made with stock trays located in a standardized position. Implant analog master casts were fabricated for the closed-tray and open-tray techniques using a standardized protocol and including a reference sphere. The Robocast technology was used to position implant analogs for the CADCAM protocol. After generating the master cast, the measuring spheres were attached to the analogs, sprayed and scanned. Computerized measurements were made of the accuracy of the analog transfers in the master casts to the locations of the patient model implants and these measurements were compared statistically. Analysis was performed on each site individually as well as parallel versus non-parallel. The analysis on the parallel implants resulted in the following mean differences from the master cast: open-tray (O) = 19.3 ± 19.6 um, closed-tray (C) = 34.9 ± 22.1 um, and encode (E) = 86.5 ± 73.9 um. The analysis on the non-parallel implants resulted in the following mean differences from the master cast: O = 49.6 ± 57.8 um, C = 54.7 ± 59.5 um, and E = 122.9 ± 63.4 um. In the analysis of individual implant positions, the mean differences from the master in each test group were calculated. Site #18 produced the following values: C = 66.2 ± 80.4 um, O = 73.9 ± 74.9 um, E = 126.7 ± 73.9 um. Site #20 produced the following values: O = 25.3 ± 24.5 um, C = 43.2 ± 38.0 um, E = 119.0 ± 62.3 um. Site #29 produced the following values: O = 22.2 ± 27.0 um, C = 25.1 ± 7.2 um, E = 131.3 ± 82.5 um. Site #31 produced the following values: O = 16.4 ± 12.1 um, C = 44.8 ± 28.8 um, E = 41.7 ± 24.5 um. Within the non-parallel implant groups, the Encode impression/cast group was less accurate than the open-tray group (p

Contemporary Fixed Prosthodontics 6e, South Asia Edition - E-Book

Download Contemporary Fixed Prosthodontics 6e, South Asia Edition - E-Book PDF Online Free

Author :
Publisher : Elsevier Health Sciences
ISBN 13 : 8131267067
Total Pages : 947 pages
Book Rating : 4.1/5 (312 download)

DOWNLOAD NOW!


Book Synopsis Contemporary Fixed Prosthodontics 6e, South Asia Edition - E-Book by : Stephen F Rosenstiel, Bds Msd

Download or read book Contemporary Fixed Prosthodontics 6e, South Asia Edition - E-Book written by Stephen F Rosenstiel, Bds Msd and published by Elsevier Health Sciences. This book was released on 2022-11-05 with total page 947 pages. Available in PDF, EPUB and Kindle. Book excerpt: With more than 3500 high-quality drawings and photographs, this complete referenceprovides a solid foundation in basic science as well as step-by-step guidelines tohundreds of fixed prosthodontic procedures. Separate sections on planning andpreparation, clinical procedures, and laboratory procedures make it easier to look upthe information you need. - Illustrated procedures walk you through all the steps of treatment fromthe beginning to the final treatment result.- Summary charts provide a quick review of specific procedures such as ClassII inlay preparation and ceramic crown preparation, highlighting the indications, contraindications, advantages, disadvantages, preparation steps, recommendedarmamentarium, and criteria.- Prosthodontic Diagnostic Index helps you determine the appropriate treatmentsfor completely edentulous, partially edentulous, and dentate patients.

The Effect of Digital Implant Analog Design on the Trueness of Implant Analog Position in Additively Manufactured Digital Implant Models

Download The Effect of Digital Implant Analog Design on the Trueness of Implant Analog Position in Additively Manufactured Digital Implant Models PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 95 pages
Book Rating : 4.:/5 (132 download)

DOWNLOAD NOW!


Book Synopsis The Effect of Digital Implant Analog Design on the Trueness of Implant Analog Position in Additively Manufactured Digital Implant Models by : Severino J. Mata

Download or read book The Effect of Digital Implant Analog Design on the Trueness of Implant Analog Position in Additively Manufactured Digital Implant Models written by Severino J. Mata and published by . This book was released on 2020 with total page 95 pages. Available in PDF, EPUB and Kindle. Book excerpt: Statement of problem. Additively manufactured (AM) digital implant models (DIM) fabricated with 3D-printing technology have become more popular in the recent years, combining the advantages of both digital and analog workflows. They are a physical model on which dentists and laboratory technicians can evaluate and work on restorations for layering and adjustments. Even though 3D-printed DIMs have provided a solution between digital and analog workflows, limited evidence exists regarding the accuracy of the implant analog position on these models. Multiple factors related to the fabrication and accuracy of 3D-printed DIMs have been studied. However, the influence of the digital implant analog design on the accuracy of implant analog positions on 3D-printed models is still unclear and only one study related to this topic has been published. Purpose. To compare the implant analog position trueness between AM DIMs with 3 different digital implant analog designs and conventional implant analog stone casts. The study aimed to evaluate and compare the effect of digital implant analog design and insertion on the trueness of analog position of DIMs compared to a conventional implant stone cast. Materials and Methods. A modified partially edentulous maxillary implant model with a conventional implant replica (Nobel Biocare Implant Replica CC RP) on site #13 was used as the master reference model (MRM). Conventional implant-level vinylpolysiloxane (VPS) impressions of the MRM were made using custom trays with the closed tray impression technique and poured in type IV stone to obtain 12 conventional implant casts (Group A, n=12). A complete-arch implant-level digital scan of the MRM with an implant intraoral scan body (ISB) was made using an intraoral scanner (IOS). The digital scan file was exported to a dental CAD software and used to create 3 different DIM designs for different 3 different DIM analogs: NobelProcera (Group B), Elos Medtech (Group C) and Nt-trading (Group D). DIMs were additively manufactured with a Continuous Liquid Interface Production (CLIP) technology 3D printer and DIM analogs were subsequently inserted into each DIM, obtaining 12 specimens per group (n=12). The MRM and all specimens were digitized with an implant ISB using a laboratory scanner, and all STL files were prepared for measurements. A metrology software was used to measure deviations between the MRM scan file to each specimen file. Linear deviations at strategic points on the ISB were measured at the level of x-, y- and z- directions and 3D linear deviation was calculated. Angular deviations at the buccolingual (BL) and mesiodistal (MD) planes of projection were measured on the ISB. ANOVA and Bonferroni corrected t-tests of pairwise comparisons were conducted for statistical analysis of linear and angular deviations of ISBs on all groups to determine the trueness of implant analog positions. An alpha level of 0.05 was used. Results. A highly statistically significant interaction was found between main effects (groups, points, directions) for linear deviation of implant analog position on models compared to the MRM. Statistically significant differences for linear deviations were found between conventional implant casts and DIMs. On the BL direction for linear deviation, statistically significant differences were found between groups A and D (P

Evidence-based Implant Treatment Planning and Clinical Protocols

Download Evidence-based Implant Treatment Planning and Clinical Protocols PDF Online Free

Author :
Publisher : John Wiley & Sons
ISBN 13 : 1119080045
Total Pages : 404 pages
Book Rating : 4.1/5 (19 download)

DOWNLOAD NOW!


Book Synopsis Evidence-based Implant Treatment Planning and Clinical Protocols by : Steven J. Sadowsky

Download or read book Evidence-based Implant Treatment Planning and Clinical Protocols written by Steven J. Sadowsky and published by John Wiley & Sons. This book was released on 2016-11-21 with total page 404 pages. Available in PDF, EPUB and Kindle. Book excerpt: Evidence-based Implant Treatment Planning and Clinical Protocols provides a systematic approach to making treatment decisions and performing restorative procedures. Offers a clinically relevant resource grounded in the latest research Applies an evidence-based approach to all aspects of implant dentistry, including maxillofacial prosthodontics, from planning to surgery and restoration Describes procedures in detail with accompanying images Covers all stages of treatment, from planning to execution Includes access to a companion website with video clips demonstrating procedures and the figures from the book in PowerPoint

Comparative in Vitro Study of the Accuracy of Impression Techniques for Dental Implants- Direct Technique with an Elastomeric Impression Material Versus Intraoral Scanner

Download Comparative in Vitro Study of the Accuracy of Impression Techniques for Dental Implants- Direct Technique with an Elastomeric Impression Material Versus Intraoral Scanner PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (116 download)

DOWNLOAD NOW!


Book Synopsis Comparative in Vitro Study of the Accuracy of Impression Techniques for Dental Implants- Direct Technique with an Elastomeric Impression Material Versus Intraoral Scanner by : Cristina Rech

Download or read book Comparative in Vitro Study of the Accuracy of Impression Techniques for Dental Implants- Direct Technique with an Elastomeric Impression Material Versus Intraoral Scanner written by Cristina Rech and published by . This book was released on 2017 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The design and fabrication of implant-supported prosthetic structures requires the faithful reproduction of anatomical details and the correct positioning of the implants in the jaw. To do this, it is essential to take impressions using silicones or polyethers that will provide a working model that is as precise and exact as possible and will lead to a prosthetic structure with adequate passive fit.In recent years, the introduction of digital workflow has brought about a revolution in the field of dentistry, particularly in relation to the fabrication of prosthetic structures, whether tooth- or implant-supported. Digital techniques have allowed greater management of technical errors in metal-casting, making it easier to achieve a correct prosthetic fit. This study aimed to compare two impression techniques for analogue implants: the direct (or pick-up) technique with the elastomeric material polyether, and a digital scanner (True Definitionu00ae, 3Mu00ae ESPE: USA), in order to determine which is the more accurate technique. Twenty impressions were taken of a master model with each technique. Were measured the distances between contiguous analogues, intermittently positioned analogues and the most distal implants. Only significant differences were found between both techniques and the master model for the distance between distal analogues.After analizing the results of this study, for rehabilitations involving more than four implants, neither technique can be considered accurate although error falls within the tolerance limits established in the literature (30-150u00b5m).

Tissue-integrated Prostheses

Download Tissue-integrated Prostheses PDF Online Free

Author :
Publisher : Quintessence Publishing (IL)
ISBN 13 :
Total Pages : 360 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Tissue-integrated Prostheses by : Per-Ingvar Brånemark

Download or read book Tissue-integrated Prostheses written by Per-Ingvar Brånemark and published by Quintessence Publishing (IL). This book was released on 1985 with total page 360 pages. Available in PDF, EPUB and Kindle. Book excerpt: " This book provides the prosthodontist and oral surgeon for the first time with a safe, predictable, and scientifically proven method for permanently anchoring artificial tooth abutments in the jawbones. It combines the osseointegration research results of biologists, physicists, bioengineers, oral surgeons, and prosthodontists to demonstrate step-by-step how to achieve long-term osseointegration of dental implants" -- Amazon.

Digital Workflow in Reconstructive Dentistry

Download Digital Workflow in Reconstructive Dentistry PDF Online Free

Author :
Publisher : Quintessenz Verlag
ISBN 13 : 3868675515
Total Pages : 467 pages
Book Rating : 4.8/5 (686 download)

DOWNLOAD NOW!


Book Synopsis Digital Workflow in Reconstructive Dentistry by : Wael Att

Download or read book Digital Workflow in Reconstructive Dentistry written by Wael Att and published by Quintessenz Verlag. This book was released on 2021-02-01 with total page 467 pages. Available in PDF, EPUB and Kindle. Book excerpt: Digital Workflow in Reconstructive Dentistry is the result of efforts made by the academic team at the Department of Prosthodontics, University Hospital of Freiburg. It aims to build a fundamental understanding of the general principles, science, and clinics of digital dental medicine. The information provided within these pages summarizes the various components of the digital workflow in reconstructive dentistry and discusses their advantages and disadvantages. Moreover, insights are provided about upcoming, game-changing technologies. By reading this book, students, clinicians, and researchers will gain and enhance their knowledge about digital dental medicine and identify the areas they need to focus on next in order to integrate the available technologies in their daily work. Clearly, the path of digital dental medicine will not stop here. Contributors Amirah M. R. Alammar • Abdulaziz Alsahaf • Wael Att • Maria Bateli • Jasmin Bernhart • Shaza Bishti • Sarah Blattner • Miha Brezavšček • Sandy Cepa • Nadine Emmanoulidi • Ahmed Fawzy • Manrique Fonseca • Michele Frapporti • Rumpa Ganguly • Yousef Al-Ghamdi • Petra Ch. Gierthmuehlen • Aiste Gintaute • Ulrich Lamott • Christos Lamprinos • Matthias Petsch • Udo Plaster • Aikaterini Ploumaki • Hanna Rauberger • Elisabeth Schwartzkopff • Christian F. Selz • Thamer Al-Sharif • Benedikt Spies • Frank A. Spitznagel • Jörg R. Strub • Michael Swain • Taskin Tuna • Alexander Vuck • Siegbert Witkowski

Issues in Contemporary Orthodontics

Download Issues in Contemporary Orthodontics PDF Online Free

Author :
Publisher : BoD – Books on Demand
ISBN 13 : 9535121618
Total Pages : 288 pages
Book Rating : 4.5/5 (351 download)

DOWNLOAD NOW!


Book Synopsis Issues in Contemporary Orthodontics by : Farid Bourzgui

Download or read book Issues in Contemporary Orthodontics written by Farid Bourzgui and published by BoD – Books on Demand. This book was released on 2015-09-03 with total page 288 pages. Available in PDF, EPUB and Kindle. Book excerpt: Issues in Contemporary Orthodontics is a contribution to the ongoing debate in orthodontics, a discipline of continuous evolution, drawing from new technology and collective experience, to better meet the needs of students, residents, and practitioners of orthodontics. The book provides a comprehensive view of the major issues in orthodontics that have featured in recent debates. Abroad variety of topics is covered, including the impact of malocclusion, risk management and treatment, and innovation in orthodontics.

Full-arch Implant Rehabilitation

Download Full-arch Implant Rehabilitation PDF Online Free

Author :
Publisher : Quintessence Publishing (IL)
ISBN 13 : 9780867158090
Total Pages : 0 pages
Book Rating : 4.1/5 (58 download)

DOWNLOAD NOW!


Book Synopsis Full-arch Implant Rehabilitation by : Arun K. Garg

Download or read book Full-arch Implant Rehabilitation written by Arun K. Garg and published by Quintessence Publishing (IL). This book was released on 2019 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: "Describes how the full-arch implant rehabilitation (FAIR) protocol works, who it should be used for, and methods to implement it successfully for different patients, in different arches, and in different initial clinical situations"--