Spherical Proportional Counter

Download Spherical Proportional Counter PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 24 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Spherical Proportional Counter by : H. Agnew

Download or read book Spherical Proportional Counter written by H. Agnew and published by . This book was released on 1946 with total page 24 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Design, Construction and Implementation of Spherical Tissue Equivalent Proportional Counter

Download Design, Construction and Implementation of Spherical Tissue Equivalent Proportional Counter PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (747 download)

DOWNLOAD NOW!


Book Synopsis Design, Construction and Implementation of Spherical Tissue Equivalent Proportional Counter by : Delia Perez Nunez

Download or read book Design, Construction and Implementation of Spherical Tissue Equivalent Proportional Counter written by Delia Perez Nunez and published by . This book was released on 2011 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Tissue equivalent proportional counters (TEPC) are used for medical and space activities whenever a combination of high and low LET (lineal energy transfer) radiations are present. With the frequency and duration of space activities increasing, exposure to fast heavy ions from galactic cosmic radiation and solar events is a major concern. The optimum detector geometry is spherical; to obtain an isotropic response, but simple spherical detectors have the disadvantage of a non-uniform electric field. In order to achieve a uniform electric field along the detector axis, spherical tissue equivalent proportional counters have been designed with different structures to modify the electric field. Some detectors use a cylindrical coil that is coaxial with the anode, but they are not reliable because of their sensitivity to microphonic noise and insufficient mechanical strength. In this work a new spherical TEPC was developed. The approach used was to divide the cathode in several rings with different thicknesses, and adjust the potential difference between each ring and the anode to produce an electric field that is nearly constant along the length of the anode. A-150 tissue equivalent plastic is used for the detector walls, the insulator material between the cathode rings is low density polyethylene, and the gas inside the detector is propane. The detector, along with the charge sensitive preamplifier, is encased in a stainless steel vacuum chamber. The gas gain was found to be 497.5 at 782 volts and the response to neutrons as a function of angle was constant ±7%. This spherical tissue equivalent proportional counter detector system will improve the accuracy of dosimetry in space, and as a result improve radiation safety for astronauts.

A High Resolution Spherical Proportional Counter

Download A High Resolution Spherical Proportional Counter PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (32 download)

DOWNLOAD NOW!


Book Synopsis A High Resolution Spherical Proportional Counter by : P. W. Benjamin

Download or read book A High Resolution Spherical Proportional Counter written by P. W. Benjamin and published by . This book was released on 1964 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

The use of spherical proportional counters for newtron spectrum measurements

Download The use of spherical proportional counters for newtron spectrum measurements PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 85 pages
Book Rating : 4.:/5 (865 download)

DOWNLOAD NOW!


Book Synopsis The use of spherical proportional counters for newtron spectrum measurements by : C. D. Kemshall

Download or read book The use of spherical proportional counters for newtron spectrum measurements written by C. D. Kemshall and published by . This book was released on 1973 with total page 85 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Searching for Light Dark Matter with a Spherical Proportional Counter

Download Searching for Light Dark Matter with a Spherical Proportional Counter PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (135 download)

DOWNLOAD NOW!


Book Synopsis Searching for Light Dark Matter with a Spherical Proportional Counter by : Patrick Ryan Knights

Download or read book Searching for Light Dark Matter with a Spherical Proportional Counter written by Patrick Ryan Knights and published by . This book was released on 2021 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

The Use of a Gas-filled Spherical Propotional Counter for Neutron Spectrum Measurements in a Zero Energy Fast Reactor

Download The Use of a Gas-filled Spherical Propotional Counter for Neutron Spectrum Measurements in a Zero Energy Fast Reactor PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 20 pages
Book Rating : 4.:/5 (929 download)

DOWNLOAD NOW!


Book Synopsis The Use of a Gas-filled Spherical Propotional Counter for Neutron Spectrum Measurements in a Zero Energy Fast Reactor by :

Download or read book The Use of a Gas-filled Spherical Propotional Counter for Neutron Spectrum Measurements in a Zero Energy Fast Reactor written by and published by . This book was released on 1964 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt:

The Response of a Spherical Tissue-equivalent Proportional Counter to Different Ions Having Similar LET.

Download The Response of a Spherical Tissue-equivalent Proportional Counter to Different Ions Having Similar LET. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 5 pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis The Response of a Spherical Tissue-equivalent Proportional Counter to Different Ions Having Similar LET. by :

Download or read book The Response of a Spherical Tissue-equivalent Proportional Counter to Different Ions Having Similar LET. written by and published by . This book was released on 2003 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt:

The Response of a Spherical Tissue-equivalent Proportional Counter to Different Heavy Ions with Similar Velocities

Download The Response of a Spherical Tissue-equivalent Proportional Counter to Different Heavy Ions with Similar Velocities PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 294 pages
Book Rating : 4.:/5 (622 download)

DOWNLOAD NOW!


Book Synopsis The Response of a Spherical Tissue-equivalent Proportional Counter to Different Heavy Ions with Similar Velocities by : Phillip James Taddei

Download or read book The Response of a Spherical Tissue-equivalent Proportional Counter to Different Heavy Ions with Similar Velocities written by Phillip James Taddei and published by . This book was released on 2005 with total page 294 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Gaseous Radiation Detectors

Download Gaseous Radiation Detectors PDF Online Free

Author :
Publisher : Cambridge University Press
ISBN 13 : 1107043018
Total Pages : 513 pages
Book Rating : 4.1/5 (7 download)

DOWNLOAD NOW!


Book Synopsis Gaseous Radiation Detectors by : Fabio Sauli

Download or read book Gaseous Radiation Detectors written by Fabio Sauli and published by Cambridge University Press. This book was released on 2014-06-12 with total page 513 pages. Available in PDF, EPUB and Kindle. Book excerpt: Describes the fundamentals and applications of gaseous radiation detection, ideal for researchers and experimentalists in nuclear and particle physics.

Calculations of the response functions of Bonner spheres with a spherical _1hn3He proportional counter using a realistic detector model

Download Calculations of the response functions of Bonner spheres with a spherical _1hn3He proportional counter using a realistic detector model PDF Online Free

Author :
Publisher :
ISBN 13 : 9783894295639
Total Pages : 84 pages
Book Rating : 4.2/5 (956 download)

DOWNLOAD NOW!


Book Synopsis Calculations of the response functions of Bonner spheres with a spherical _1hn3He proportional counter using a realistic detector model by : Burkhard Wiegel

Download or read book Calculations of the response functions of Bonner spheres with a spherical _1hn3He proportional counter using a realistic detector model written by Burkhard Wiegel and published by . This book was released on 1994 with total page 84 pages. Available in PDF, EPUB and Kindle. Book excerpt:

A Precision Alpha Proportional Counter

Download A Precision Alpha Proportional Counter PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 14 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis A Precision Alpha Proportional Counter by : J. A. Simpson

Download or read book A Precision Alpha Proportional Counter written by J. A. Simpson and published by . This book was released on 1946 with total page 14 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Design, Construction and Use of Tissue Equivalent Proportional Counters

Download Design, Construction and Use of Tissue Equivalent Proportional Counters PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 124 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Design, Construction and Use of Tissue Equivalent Proportional Counters by : Th Schmitz

Download or read book Design, Construction and Use of Tissue Equivalent Proportional Counters written by Th Schmitz and published by . This book was released on 1995 with total page 124 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Design and Construction of a Compact Multi-chamber Tissue Equivalent Proportional Counter

Download Design and Construction of a Compact Multi-chamber Tissue Equivalent Proportional Counter PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (71 download)

DOWNLOAD NOW!


Book Synopsis Design and Construction of a Compact Multi-chamber Tissue Equivalent Proportional Counter by : Temeka Taplin

Download or read book Design and Construction of a Compact Multi-chamber Tissue Equivalent Proportional Counter written by Temeka Taplin and published by . This book was released on 2006 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This project was designed to determine the feasibility of constructing a multi-chamber proportional counter. A multi-chamber detector is designed to increase the total surface area which will increase the number of radiation interactions that occur per unit dose. Surface area can be changed without changing the detector volume by subdividing the active volume into several smaller volumes that can then be used as mini detectors whose data can be summed and used to determine the absorbed dose. This will allow the total surface area to remain the same as that of the more common 12.5 cm (5 in.) spherical detector and a decreased total volume resulting in a more compact detector design. However, subdividing those volumes causes problems with electric field fringing at the ends of the mini detectors. In order to correct this, guard ring and field tube designs which operate at a lower voltage than the detector cathode were tested. Results from this study showed that the field tube design provided the best overall resolution but it only outperformed the other designs by a maximum of 5%. However the field tube design doubles the length of the detector which would result in a larger overall detector package. The performance of the single and double ring configurations was suitable for radiation monitoring applications. These findings show that it is feasible to use an arrayof subdivided detector volumes instead of a spherical detector.

The Response of a Spherical Tissue-equivalent Proportional Counter to 56-Fe Particles from 200-1000 MeV

Download The Response of a Spherical Tissue-equivalent Proportional Counter to 56-Fe Particles from 200-1000 MeV PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis The Response of a Spherical Tissue-equivalent Proportional Counter to 56-Fe Particles from 200-1000 MeV by :

Download or read book The Response of a Spherical Tissue-equivalent Proportional Counter to 56-Fe Particles from 200-1000 MeV written by and published by . This book was released on 2001 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The radiation environment aboard the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 is considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPC) are used as active dosimeters on manned space flights. These TEPC's are further used to determine average quality factor for each space mission. A TEPC simulating a 1 micron diameter sphere of tissue was exposed as part of a particle spectrometer to iron-56 at energies from 200-1000 MeV/nucleon. The response of TEPC in terms of frequency-averaged lineal energy, dose-averaged lineal energy, as well as energy deposited at different impact parameters through detector was determined for six different incident energies of iron-56 in this energy range. Calculations determined that charged particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model and the results compared to experimental data.

The Response of a Spherical Tissue-equivalent Proportional Counter to Iron Particles from 200--1000 MeV/nucleon

Download The Response of a Spherical Tissue-equivalent Proportional Counter to Iron Particles from 200--1000 MeV/nucleon PDF Online Free

Author :
Publisher :
ISBN 13 : 9781109848656
Total Pages : 146 pages
Book Rating : 4.8/5 (486 download)

DOWNLOAD NOW!


Book Synopsis The Response of a Spherical Tissue-equivalent Proportional Counter to Iron Particles from 200--1000 MeV/nucleon by : Brad B. Gersey

Download or read book The Response of a Spherical Tissue-equivalent Proportional Counter to Iron Particles from 200--1000 MeV/nucleon written by Brad B. Gersey and published by . This book was released on 2006 with total page 146 pages. Available in PDF, EPUB and Kindle. Book excerpt: The radiation environment aboard the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. The 56Fe ion is considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPC) are used as active dosimeters on manned space flights. These TEPC's are further used to determine average quality factor for each space mission. A TEPC simulating a 1-mum diameter sphere of tissue was exposed as part of a particle spectrometer to 56Fe at energies from 200-1000 MeV/nucleon. The response of TEPC in terms of mean lineal energy y¯F, and dose mean lineal energy, y¯ D, as well as energy deposited at different impact parameters through detector was determined for six different incident energies of 56Fe in this energy range. Calculations determined that charged particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using the spatially restricted LET model, a radial dose distribution model. Energy deposition at one impact parameter (0-mm) was calculated with a track structure model code called BTC4. Results from these three model calculations were compared to experimental data.

Design and Characterization of Next-generation Tissue Equivalent Proportional Counters for Use in Low Energy Neutron Fields

Download Design and Characterization of Next-generation Tissue Equivalent Proportional Counters for Use in Low Energy Neutron Fields PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (13 download)

DOWNLOAD NOW!


Book Synopsis Design and Characterization of Next-generation Tissue Equivalent Proportional Counters for Use in Low Energy Neutron Fields by : Fawaz Ali

Download or read book Design and Characterization of Next-generation Tissue Equivalent Proportional Counters for Use in Low Energy Neutron Fields written by Fawaz Ali and published by . This book was released on 2014 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Theoretical Performance Analysis of a Novel Hemispherical Tissue Equivalent Proportional Counter for Neutron Monitoring and Dosimetry

Download Theoretical Performance Analysis of a Novel Hemispherical Tissue Equivalent Proportional Counter for Neutron Monitoring and Dosimetry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (13 download)

DOWNLOAD NOW!


Book Synopsis Theoretical Performance Analysis of a Novel Hemispherical Tissue Equivalent Proportional Counter for Neutron Monitoring and Dosimetry by : David Broughton

Download or read book Theoretical Performance Analysis of a Novel Hemispherical Tissue Equivalent Proportional Counter for Neutron Monitoring and Dosimetry written by David Broughton and published by . This book was released on 2016 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: