Reconstruction D'Images en Tomographie D'Émission Monophotonique

Download Reconstruction D'Images en Tomographie D'Émission Monophotonique PDF Online Free

Author :
Publisher : Omniscriptum
ISBN 13 : 9786131500541
Total Pages : 108 pages
Book Rating : 4.5/5 (5 download)

DOWNLOAD NOW!


Book Synopsis Reconstruction D'Images en Tomographie D'Émission Monophotonique by : Elie Nasr

Download or read book Reconstruction D'Images en Tomographie D'Émission Monophotonique written by Elie Nasr and published by Omniscriptum. This book was released on 2010-04 with total page 108 pages. Available in PDF, EPUB and Kindle. Book excerpt: Ce livre traite de reconstruction d'images partir de projections parall les att nu es. Ce probl me math matique trouve son application principale en imagerie m dicale, et en particulier en tomographie d' mission monophotonique avec correction d'att nuation sous l'hypoth se que l'att nuation (suppos e quelconque) est connue et quelconque sur la r gion d' mission. Dans un premier temps, nous d crivons les principes physiologiques et math matiques de la tomographie d' mission monophotonique. Ensuite, nous pr sentons une m thode de reconstruction it rative bas e sur la prise en consid ration du ph nom ne d'att nuation, principal l ment perturbateur en imagerie par mission monophotonique. Cette m thode est une g n ralisation de l'algorithme de reconstruction alg brique classique (ART); elle introduit un terme de correction d'att nuation exact. Finalement, nous exposerons des exemples num riques et nous discuterons de la performance de notre algorithme selon le choix de plusieurs param tres.

Reconstruction d'images cardiaques en tomographie d'émission monophotonique à l'aide de modèles spatio-temporels

Download Reconstruction d'images cardiaques en tomographie d'émission monophotonique à l'aide de modèles spatio-temporels PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 207 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis Reconstruction d'images cardiaques en tomographie d'émission monophotonique à l'aide de modèles spatio-temporels by : Jérôme de Murcia

Download or read book Reconstruction d'images cardiaques en tomographie d'émission monophotonique à l'aide de modèles spatio-temporels written by Jérôme de Murcia and published by . This book was released on 1996 with total page 207 pages. Available in PDF, EPUB and Kindle. Book excerpt: LA TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE FOURNIT UNE SEQUENCE D'IMAGES 3D REPRESENTATIVES DE LA DISTRIBUTION DU TRACEUR ADMINISTRE AU PATIENT, POUR DIFFERENTS INSTANTS DU CYCLE CARDIAQUE. ELLE MET EN EVIDENCE LES ZONES MAL IRRIGUEES DU MYOCARDE. AFIN D'EVITER UNE TROP LONGUE IMMOBILISATION, LES TEMPS D'ACQUISITION SONT LIMITES, CE QUI CONDUIT A DES MESURES TRES BRUITEES. LA RECONSTRUCTION ETANT UN PROBLEME INVERSE MAL-POSE, LES IMAGES TOMOGRAPHIQUES SONT ALORS TRES DEGRADEES. NOUS PROPOSONS DANS CETTE THESE DEUX METHODES PERMETTANT D'AMELIORER LA QUALITE STATISTIQUE DE CES IMAGES EN REGULARISANT TEMPORELLEMENT LE PROCESSUS DE RECONSTRUCTION. LA SIMPLE MOYENNE TEMPORELLE CONDUISANT A UN FLOU CINETIQUE, LE MOUVEMENT DU MYOCARDE EST D'ABORD ESTIME A PARTIR DU SUIVI DE TROIS SURFACES CARACTERISTIQUES DU MYOCARDE, PUIS INTEGRE DANS L'ALGORITHME DE RECONSTRUCTION. LA PREMIERE METHODE DEVELOPPEE CONSISTE A RECONSTRUIRE UNE PHASE PARTICULIERE CONNAISSANT L'ENSEMBLE DES MESURES ACQUISES ET LA LOI D'EVOLUTION. LA RECONSTRUCTION S'INSCRIT DANS LE CADRE THEORIQUE DU FILTRAGE DE KALMAN. LA SOLUTION FORMELLE NECESSITANT L'INVERSION D'UNE MATRICE DE TRES GRANDE DIMENSION, NOUS PROPOSONS UNE SOLUTION SOUS-OPTIMALE MAIS RAPIDE. L'ALGORITHME RECURSIF REPOSE SUR DES OPERATIONS DE TYPE FILTRAGE-RETROPROPJECTION. NOUS PRESENTONS ENSUITE UNE DEUXIEME APPROCHE DANS LAQUELLE L'ENSEMBLE DES PHASES EST RECONSTRUITE SIMULTANEMENT. LA RECONSTRUCTION DE LA SEQUENCE EST EFFECTUEE PAR MINIMISATION D'UNE FONCTION QUADRATIQUE ETABLIE DANS LE CADRE D'UNE REGULARISATION SPATIO-TEMPORELLE. LE CALCUL ITERATIF DES IMAGES EST EFFECTUE A PARTIR DE L'ALGORITHME DU GRADIENT CONJUGUE. LES RESULTATS EXPERIMENTAUX MONTRENT LA VALIDITE DE NOTRE APPROCHE ET METTENT EN EVIDENCE L'APPORT D'UNE REGULARISATION TEMPORELLE

Optimisation et validation d'un algorithme de reconstruction 3D en tomographie d'émission monophotonique à l'aide de la plateforme de simulation GATE

Download Optimisation et validation d'un algorithme de reconstruction 3D en tomographie d'émission monophotonique à l'aide de la plateforme de simulation GATE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 209 pages
Book Rating : 4.:/5 (494 download)

DOWNLOAD NOW!


Book Synopsis Optimisation et validation d'un algorithme de reconstruction 3D en tomographie d'émission monophotonique à l'aide de la plateforme de simulation GATE by : Ziad El Bitar

Download or read book Optimisation et validation d'un algorithme de reconstruction 3D en tomographie d'émission monophotonique à l'aide de la plateforme de simulation GATE written by Ziad El Bitar and published by . This book was released on 2006 with total page 209 pages. Available in PDF, EPUB and Kindle. Book excerpt: Les simulations de Monte-Carlo, bien que consommatrices en temps de calcul, restent un outil puissant qui permet d'évaluer les méthodes de correction des effets physiques en imagerie médicale. Nous avons optimisé et validé une méthode de reconstruction baptisée F3DMC (Fully3D Monte CARLO) dans laquelle les effets physiques perturbant le processus de formation de l'image en tomographie d'émission monophotonique sont modélisés par des méthodes de Monte-Carlo et intégrés dans la matrice-système. Le logiciel de simulation de Monte-Carlo utilidé est GATE. Nous avons validé GATE en SPECT en modélisant la gamma-caméra (Philips AXIS) utilisé en routine clinique. Des techniques de seuillage, filtrage par analyse en composantes principales et de reconstruction ciblée (régions fonctionnelles, région hybrides) ont été testées pour améliorer la précision de la matrice-système et réduire le nombre de photons ainsi que le temps de calcul nécessaires. Les infrastructures de la grille EGEE ont été utilisées pour déployer les simulations GATE afin de réduire leur temps de calcul. Les résultats obtenus avec F3DMC sont comparés avec les méthodes de reconstruction (FBP,ML-EM,ML-EMC) pour un fantôme simulé et avec la méthode OSEM-C pour un fantôme réel

Etude comparative par simulation de différentes méthodes de reconstruction en tomographie d'émission monophotonique en présence de bruit statistique. Influence de différents paramètres d'acquisition et de reconstruction sur la qualité de l'image reconstruite

Download Etude comparative par simulation de différentes méthodes de reconstruction en tomographie d'émission monophotonique en présence de bruit statistique. Influence de différents paramètres d'acquisition et de reconstruction sur la qualité de l'image reconstruite PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 352 pages
Book Rating : 4.:/5 (489 download)

DOWNLOAD NOW!


Book Synopsis Etude comparative par simulation de différentes méthodes de reconstruction en tomographie d'émission monophotonique en présence de bruit statistique. Influence de différents paramètres d'acquisition et de reconstruction sur la qualité de l'image reconstruite by : Sahreddin Ibrahim Issa

Download or read book Etude comparative par simulation de différentes méthodes de reconstruction en tomographie d'émission monophotonique en présence de bruit statistique. Influence de différents paramètres d'acquisition et de reconstruction sur la qualité de l'image reconstruite written by Sahreddin Ibrahim Issa and published by . This book was released on 1992 with total page 352 pages. Available in PDF, EPUB and Kindle. Book excerpt: NOS TRAVAUX DANS CETTE THESE SE SONT ORGANISES AUTOUR DE DEUX AXES PRINCIPAUX: LA PROGRAMMATION ET L'UTILISATION DE TROIS METHODES DE LA RECONSTRUCTION TOMOGRAPHIQUE: LA METHODE DE RETROPROJECTION FILTREE AVEC LES DIFFERENTS FILTRES CLASSIQUES, LA METHODE DU MAXIMUM DE VRAISEMBLANCE ET LA METHODE ALGEBRIQUE ART, EN TENANT COMPTE DU BRUIT STATISTIQUE DANS LES DONNEES DES PROJECTIONS. CETTE UTILISATION NOUS A PERMIS L'ETUDE DE L'INFLUENCE DE DIFFERENTS PARAMETRES D'ACQUISITION (NOMBRE DE PROJECTIONS PAR ACQUISITION ET TEMPS D'ACQUISITION PAR PROJECTION) ET DE RECONSTRUCTION (FILTRAGE, NOMBRE D'ITERATIONS ET FACTEUR DE RELAXATION) SUR LA QUALITE DE L'IMAGE RECONSTRUITE. LA QUALITE DE CETTE IMAGE A ETE MESUREE AU COURS DE CETTE ETUDE EN TERME: DE LA RESOLUTION SPATIALE, DU BRUIT (B), DU CONTRASTE (C), DU RAPPORT (C/B) ET DU COEFFICIENT DE CORRELATION ENTRE L'OBJET ET SON IMAGE RECONSTRUITE; L'ETUDE COMPARATIVE DE LA QUALITE DE LA RECONSTRUCTION ENTRE LES TROIS METHODES, EN TERME DE DIFFERENTS CRITERES DE QUALITE DE L'IMAGE DANS LE CAS DE DONNEES PEU BRUITEES ET TRES BRUITEES. CETTE ETUDE NOUS A PERMIS DE SITUER LES PERFORMANCES DE LA METHODE DU MAXIMUM DE VRAISEMBLANCE VENANT D'ETRE MISE EN SERVICE POUR LA RECONSTRUCTION TOMOGRAPHIQUE PAR RAPPORT AUX PERFORMANCES DES DEUX AUTRES METHODES LES PLUS FREQUEMMENT UTILISEES EN TOMOGRAPHIE D'EMISSION. LES RESULTATS DE CETTE ETUDE SONT EXPRIMES PAR DES FORMULES MATHEMATIQUES RELATIVES AUX METHODES DE RECONSTRUCTION LIANT CERTAINS CRITERES DE QUALITE FINALE DE L'IMAGE RECONSTRUITE A CERTAINS PARAMETRES D'IMPACT. DES APPLICATIONS CLINIQUES SUR LE CERVEAU ET LE CUR ONT ETE REALISEES MONTRANT L'INTERET DES TRAVAUX EFFECTUES EN SIMULATION

Optimisation de la reconstruction en tomographie d'émission monophotonique à l'aide de la méthode de Monte Carlo

Download Optimisation de la reconstruction en tomographie d'émission monophotonique à l'aide de la méthode de Monte Carlo PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 394 pages
Book Rating : 4.:/5 (489 download)

DOWNLOAD NOW!


Book Synopsis Optimisation de la reconstruction en tomographie d'émission monophotonique à l'aide de la méthode de Monte Carlo by : Pierre Dacouri B

Download or read book Optimisation de la reconstruction en tomographie d'émission monophotonique à l'aide de la méthode de Monte Carlo written by Pierre Dacouri B and published by . This book was released on 1994 with total page 394 pages. Available in PDF, EPUB and Kindle. Book excerpt: EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE, QUATRE FACTEURS AFFECTENT PRINCIPALEMENT LA QUANTIFICATION DES DONNEES: L'ATTENUATION, LA DIFFUSION COMPTON, LA VARIATION DE LA REPONSE DU SYSTEME DE DETECTION ET L'ALGORITHME DE RETROPROJECTION FILTREE (RPF) UTILISE EN ROUTINE. POUR PERMETTRE UNE QUANTIFICATION DES DONNEES, NOUS PROPOSONS UNE ANALYSE STOCHASTIQUE BASEE SUR LA METHODE DE MONTE CARLO DIRECTE. DANS UN PREMIER TEMPS, NOUS AVONS DECRIT LES CARACTERISTIQUES DU SYSTEME D'ACQUISITION, ANALYSE LES DIVERSES METHODES DE RECONSTRUCTION D'IMAGES PROPOSEES DANS LA LITTERATURE PUIS IMPLANTE L'ALGORITHME DE VRAISEMBLANCE MAXIMALE EN RAISON DE SES POTENTIALITES. DANS UN DEUXIEME TEMPS, NOUS AVONS SIMULE LA REPONSE DU COLLIMATEUR PUIS ETUDIE SES PERFORMANCES (RESOLUTIONS, EFFICACITE GEOMETRIQUE,). NOUS AVONS CALCULE ENSUITE UNE MATRICE MC DE TRANSITION. POUR Y INCORPORER LES EFFETS D'ATTENUATION ET DE DIFFUSION, NOUS AVONS MIS EN UVRE LE CALCUL D'UNE FONCTION CORRECTIVE QUI, EN CHAQUE PIXEL, RENDE COMPTE DE CES EFFETS DEGRADANTS. LES MESURES EFFECTUEES OBTENUES AVEC CETTE METHODE, A PARTIR DE DONNEES PROJECTIVES EXPERIMENTALES, ONT MONTRE UNE AMELIORATION SENSIBLE DE LA DETECTABILITE (CONTRASTE, RAPPORT S/B) ET UNE REDUCTION DES FLUCTUATIONS STATISTIQUES SUR LA MESURE PAR RAPPORT A LA METHODE DE RPF. L'APPLICATION DE L'ESTIMATEUR DU MLE AUX DONNEES CLINIQUES PERMET D'OBTENIR DES IMAGES DU CERVEAU PLUS PRECISES AVEC UNE AMELIORATION DE LA COURONNE CORTICALE. LA VALEUR DU DEBIT SANGUIN CEREBRAL RESULTANT DE LA METHODE DE MLE EST D'ENVIRON 5% PLUS BASSE QUE LA VALEUR DE REFERENCE

Méthodes hilbertiennes pour la correction d'atténuation en tomographie d'émission monophotonique

Download Méthodes hilbertiennes pour la correction d'atténuation en tomographie d'émission monophotonique PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 116 pages
Book Rating : 4.:/5 (493 download)

DOWNLOAD NOW!


Book Synopsis Méthodes hilbertiennes pour la correction d'atténuation en tomographie d'émission monophotonique by : Elie Nasr

Download or read book Méthodes hilbertiennes pour la correction d'atténuation en tomographie d'émission monophotonique written by Elie Nasr and published by . This book was released on 2008 with total page 116 pages. Available in PDF, EPUB and Kindle. Book excerpt: Cette thèse traite de reconstruction d'images à partir de projections parallèles atténuées. Ce problème mathématique trouve son application principale en imagerie médicale, et en particulier en tomographie d'émission monophotonique avec correction d'atténuation sous l'hypothèse que l'atténuation (supposée quelconque) est connue et quelconque sur la région d'émission. Dans un premier temps, nous décrivons les principes physiologiques et mathématiques de la tomographie d'émission monophonique. Ensuite, nous présentons une méthode de reconstruction itérative basée sur la prise en considération du phénomène d'atténuation, principal élément perturbateur en imagerie par émission monophotonique. Cette méthode est une généralisation de l'algorithme de reconstruction algébrique classique (ART) ; elle introduit un terme de correction d'atténuation exact. Finalement, nous exposerons des exemples numériques et nous discuterons de la performance de notre algorithme selon le choix de plusieurs paramètres.

Optimisation de la reconstruction en tomographie d'émission monophotonique avec colimateur sténopé

Download Optimisation de la reconstruction en tomographie d'émission monophotonique avec colimateur sténopé PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 180 pages
Book Rating : 4.:/5 (22 download)

DOWNLOAD NOW!


Book Synopsis Optimisation de la reconstruction en tomographie d'émission monophotonique avec colimateur sténopé by : Vincent Israel-Jost

Download or read book Optimisation de la reconstruction en tomographie d'émission monophotonique avec colimateur sténopé written by Vincent Israel-Jost and published by . This book was released on 2006 with total page 180 pages. Available in PDF, EPUB and Kindle. Book excerpt:

QUANTIFICATION EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE

Download QUANTIFICATION EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 232 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis QUANTIFICATION EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE by : MELANIE.. PELEGRINI

Download or read book QUANTIFICATION EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE written by MELANIE.. PELEGRINI and published by . This book was released on 1997 with total page 232 pages. Available in PDF, EPUB and Kindle. Book excerpt: LE DEVELOPPEMENT D'UNE STRATEGIE GLOBALE DE TRAITEMENT DES ACQUISITIONS DE TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE, POUR OBTENIR DES INFORMATIONS QUANTITATIVES FIABLES, REQUIERT L'ETUDE DES FACTEURS LIMITANT LA PRECISION DES MESURES. NOUS AVONS PRIVILEGIE CEUX QUI NE SONT PAS TRAITES DE FACON STANDARD SUR LES CAMERAS INSTALLEES EN ROUTINE : DIFFUSION, VARIATIONS DE LA FONCTION DE REPONSE DU DETECTEUR (PSF), BRUIT DE MESURE, CARACTERE MAL POSE DU PROBLEME DE RECONSTRUCTION ET ATTENUATION. NOTRE OBJECTIF ETAIT D'ELABORER UNE METHODOLOGIE GLOBALE DE TRAITEMENT DES ACQUISITIONS, TRAITANT DE CES FACTEURS DE FACON COHERENTE ET AMELIORANT LA QUANTIFICATION. DANS NOTRE APPROCHE, LA CORRECTION DE LA DIFFUSION EST REALISEE SUR LES PROJECTIONS PAR ANALYSE FACTORIELLE SPECTRALE, METHODE ANALYSANT L'ENERGIE DE CHAQUE PHOTON DETECTE. LES VARIATIONS DE LA PSF SONT CORRIGEES PAR UNE DECONVOLUTION DES PROJECTIONS UTILISANT LE PRINCIPE FREQUENCE-DISTANCE. POUR TRAITER DES PROBLEMES DE BRUIT ET DE RECONSTRUCTION, NOUS AVONS PROPOSE UNE NOUVELLE METHODE DE RECONSTRUCTION, LA RETROPROJECTION REGULARISEE (RBP), QUI EXPLOITE LES PROPRIETES STATISTIQUES DES PROJECTIONS ET LEUR REGULARITE, POUR FILTRER LE BRUIT DE MESURE (MODELE A EFFET FIXE) ET RENDRE LE PROBLEME DE RECONSTRUCTION BIEN POSE GRACE A DES ESPACES DE TRAVAIL REGULIERS (ESPACES DE SOBOLEV). LA RBP A ETE INTEGREE DANS UNE METHODE DE REGULARISATION, ASSURANT LA CONVERGENCE DE L'ALGORITHME ITERATIF (TECHNIQUE DU RESIDU MINIMAL) UTILISE POUR CORRIGER L'ATTENUATION NON UNIFORME. CES DEVELOPPEMENTS ONT ETE COMBINES EN UN PROTOCOLE GLOBAL DE TRAITEMENT. SON APPLICATION A DES ACQUISITIONS TOMOGRAPHIQUES CARDIAQUES, SIMULEES PAR LA METHODE DE MONTE CARLO, MONTRE QU'IL AMELIORE LA PRECISION QUANTITATIVE DES IMAGES, PAR RAPPORT A DES METHODES PLUS CLASSIQUES. D'AUTRES DEVELOPPEMENTS METHODOLOGIQUES DEVRONT PORTER SUR LA DETERMINATION AUTOMATIQUE DES PARAMETRES NECESSAIRES, ET NOTRE APPROCHE DEVRA ETRE EVALUEE DE FACON PLUS EXHAUSTIVE.

CARDIAC TOMOSCINTIGRAPHIC IMAGE RECONSTRUCTION USING DATA FUSION

Download CARDIAC TOMOSCINTIGRAPHIC IMAGE RECONSTRUCTION USING DATA FUSION PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 167 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis CARDIAC TOMOSCINTIGRAPHIC IMAGE RECONSTRUCTION USING DATA FUSION by : FREDERIQUE.. COUTAND

Download or read book CARDIAC TOMOSCINTIGRAPHIC IMAGE RECONSTRUCTION USING DATA FUSION written by FREDERIQUE.. COUTAND and published by . This book was released on 1996 with total page 167 pages. Available in PDF, EPUB and Kindle. Book excerpt: LA METHODE PROPOSEE DANS CE MANUSCRIT CONSISTE A UTILISER LA FUSION DE DONNEES ANATOMIQUES POUR AMELIORER LA QUANTIFICATION DES IMAGES RECONSTRUITES EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE (T.E.M.P.). LES DONNEES ANATOMIQUES (DEDUITES D'AUTRES MODALITES) SONT UTILISEES AFIN D'OBTENIR UNE MODELISATION PARAMETRIQUE (PAR DES FONCTIONS SPLINE) DES ORGANES DE LA COUPE A RECONSTRUIRE. DANS LA PRATIQUE, ON UTILISE DEUX TYPES D'IMAGES: PREMIEREMENT DES IMAGES EN TRANSMISSION QUI SERVENT A OBTENIR LES CONTOURS DES ORGANES TELS QUE LE THORAX ET LES POUMONS. DEUXIEMEMENT, DES IMAGES EN EMISSION QUI DONNENT UNE PRELOCALISATION DE L'ACTIVITE ET UNE PREMIERE ESTIMATION DES CONTOURS DU VENTRICULE GAUCHE, QUI SONT AMELIORES AU COURS DU PROCESSUS DE RECONSTRUCTION. LE MODELE GEOMETRIQUE NOUS PERMET DE MIEUX CARACTERISER LA FORMATION DES DONNEES SCINTIGRAPHIQUES ET AINSI D'AMELIORER LE PROBLEME DIRECT. LES PRINCIPALES ORIGINALITES DE CES TRAVAUX CONSISTENT A RESTREINDRE LE CHAMP DE LA RECONSTRUCTION UNIQUEMENT AUX REGIONS ACTIVES ET D'UTILISER UN MAILLAGE ADAPTE AUX CONTOURS DES REGIONS A RECONSTRUIRE (POUR EVITER DES ERREURS DE VOLUME PARTIEL). LA REDUCTION DU NOMBRE D'INCONNUS PERMET DE MIEUX CONDITIONNER LE PROBLEME INVERSE ET AINSI DE REDUIRE LE NOMBRE DE PROJECTIONS NECESSAIRES A LA RECONSTRUCTION. LA METHODE DE RECONSTRUCTION QUI EST PROPOSEE REPOSE SUR UNE DOUBLE ESTIMATION ; ESTIMATION DE LA DISTRIBUTION DE RADIOACTIVITE A L'INTERIEUR DE NOTRE MODELE GEOMETRIQUE, ET ESTIMATION DES PARAMETRES OPTIMAUX DE CE MODELE. LES RECONSTRUCTIONS 2D A PARTIR DE DONNEES SIMULEES PUIS ENREGISTREES SUR FANTOME, ONT PERMIS DE VALIDER LE PRINCIPE DE LA METHODE ET MONTRENT UNE NETTE AMELIORATION DE LA QUANTIFICATION DES IMAGES SCINTIGRAPHIQUES

RECONSTRUCTION DES IMAGES DE TOMOGRAPHIE D'EMISSION A PHOTON UNIQUE PAR INCIDENCES MULTIPLES EN MEDECINE NUCLEAIRE

Download RECONSTRUCTION DES IMAGES DE TOMOGRAPHIE D'EMISSION A PHOTON UNIQUE PAR INCIDENCES MULTIPLES EN MEDECINE NUCLEAIRE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 139 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis RECONSTRUCTION DES IMAGES DE TOMOGRAPHIE D'EMISSION A PHOTON UNIQUE PAR INCIDENCES MULTIPLES EN MEDECINE NUCLEAIRE by : ANASTASIA.. HATZIGIANNAKI

Download or read book RECONSTRUCTION DES IMAGES DE TOMOGRAPHIE D'EMISSION A PHOTON UNIQUE PAR INCIDENCES MULTIPLES EN MEDECINE NUCLEAIRE written by ANASTASIA.. HATZIGIANNAKI and published by . This book was released on 1983 with total page 139 pages. Available in PDF, EPUB and Kindle. Book excerpt: LE COMPORTEMENT PAR RAPPORT AU BRUIT ET A LA RESOLUTION DES ALGORITHMES CONVENTIONNELLES DE RECONSTRUCTION DES IMAGES-COUPES EST ETUDIE. UNE METHODE DE CORRECTION APPORTANT UNE SOLUTION PRECISE AU PROBLEME DE L'AUTOABSORPTION EST TESTEE, AINSI QU'UNE NOUVELLE METHODE DE CORRECTION

SPECT

Download SPECT PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 260 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis SPECT by : Robert Joseph English

Download or read book SPECT written by Robert Joseph English and published by . This book was released on 1990 with total page 260 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Validation de la plate-forme de simulation GATE en Tomographie à Emission Monophotonique et application au développement d'un algorithme de reconstruction 3D complète

Download Validation de la plate-forme de simulation GATE en Tomographie à Emission Monophotonique et application au développement d'un algorithme de reconstruction 3D complète PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 200 pages
Book Rating : 4.:/5 (491 download)

DOWNLOAD NOW!


Book Synopsis Validation de la plate-forme de simulation GATE en Tomographie à Emission Monophotonique et application au développement d'un algorithme de reconstruction 3D complète by : Delphine Lazaro

Download or read book Validation de la plate-forme de simulation GATE en Tomographie à Emission Monophotonique et application au développement d'un algorithme de reconstruction 3D complète written by Delphine Lazaro and published by . This book was released on 2003 with total page 200 pages. Available in PDF, EPUB and Kindle. Book excerpt: Les simulations Monte-Carlo représentent actuellement en imagerie médicale nucléaire un outil puissant d'aide à la conception et à l'optimisation des détecteurs, et à l'évaluation des algorithmes de reconstruction et des méthodes de corrections des effets physiques. Parmi les nombreux simulateurs disponibles aujourd'hui, aucun n'est considéré comme standard en imagerie nucléaire ce qui a motivé le développement d'une nouvelle plate-forme de simulation Monte-Carlo générique (GATE), basée sur GEANT4 et dédiée aux applications SPECT/PET. Au cours de cette thèse, nous avons participé au développement de la plate-forme GATE dans le cadre d'une collaboration internationale. Nous avons validé GATE en SPECT en modélisant deux gamma-caméras de conception différente, l'une dédiée à l'imagerie du petit animal et l'autre utilisée en routine clinique (Philips, AXIS), et en comparant les résultats issus des simulations GATE avec les données acquises expérimentalement. Les résultats des simulations reproduisent avec précision les performances des deux gamma-caméras mesurées. La plate-forme GATE a ensuite été employée pour développer une nouvelle méthode de reconstruction 3D (F3DMC), consistant à calculer par simulation Monte-Carlo la matrice de transition utilisée dans un algorithme de reconstruction itératif (ici, ML-EM), en y incluant les principaux effets physiques perturbant le processus de formation de l'image. Les résulats de F3DMC sont comparés aux résultats obtenus avec trois autres méthodes de reconstruction plus classiques (FBP, MLEM, MLEMC) pour différents fantômes simulés. Les résultats de cette étude montrent que F3DMC permet d'améliorer l'efficacité de reconstruction, la résolution spatiale et le rapport signal-sur-bruit avec une quantification satisfaisante des images. Ces résultats devront être confirmés par des études cliniques et ouvrent la voie vers une méthode de reconstruction unifiée, pouvant être appliquée aussi bien en SPECT qu'en PET

Emission Tomography

Download Emission Tomography PDF Online Free

Author :
Publisher : Elsevier
ISBN 13 : 0080521878
Total Pages : 597 pages
Book Rating : 4.0/5 (85 download)

DOWNLOAD NOW!


Book Synopsis Emission Tomography by : Miles N. Wernick

Download or read book Emission Tomography written by Miles N. Wernick and published by Elsevier. This book was released on 2004-12-07 with total page 597 pages. Available in PDF, EPUB and Kindle. Book excerpt: PET and SPECT are two of today's most important medical-imaging methods, providing images that reveal subtle information about physiological processes in humans and animals. Emission Tomography: The Fundamentals of PET and SPECT explains the physics and engineering principles of these important functional-imaging methods. The technology of emission tomography is covered in detail, including historical origins, scientific and mathematical foundations, imaging systems and their components, image reconstruction and analysis, simulation techniques, and clinical and laboratory applications. The book describes the state of the art of emission tomography, including all facets of conventional SPECT and PET, as well as contemporary topics such as iterative image reconstruction, small-animal imaging, and PET/CT systems. This book is intended as a textbook and reference resource for graduate students, researchers, medical physicists, biomedical engineers, and professional engineers and physicists in the medical-imaging industry. Thorough tutorials of fundamental and advanced topics are presented by dozens of the leading researchers in PET and SPECT. SPECT has long been a mainstay of clinical imaging, and PET is now one of the world's fastest growing medical imaging techniques, owing to its dramatic contributions to cancer imaging and other applications. Emission Tomography: The Fundamentals of PET and SPECT is an essential resource for understanding the technology of SPECT and PET, the most widely used forms of molecular imaging.*Contains thorough tutorial treatments, coupled with coverage of advanced topics*Three of the four holders of the prestigious Institute of Electrical and Electronics Engineers Medical Imaging Scientist Award are chapter contributors*Include color artwork

Tomography

Download Tomography PDF Online Free

Author :
Publisher : John Wiley & Sons
ISBN 13 : 1118617673
Total Pages : 350 pages
Book Rating : 4.1/5 (186 download)

DOWNLOAD NOW!


Book Synopsis Tomography by : Pierre Grangeat

Download or read book Tomography written by Pierre Grangeat and published by John Wiley & Sons. This book was released on 2013-03-04 with total page 350 pages. Available in PDF, EPUB and Kindle. Book excerpt: The principle of tomography is to explore the structure and composition of objects non-destructively along spatial and temporal dimensions, using penetrating radiation, such as X- and gamma-rays, or waves, such as electromagnetic and acoustic waves. Based on computer-assisted image reconstruction, tomography provides maps of parameters that characterize the emission of the employed radiation or waves, or their interaction with the examined objects, for one or several cross-sections. Thus, it gives access to the inner structure of inert objects and living organisms in their full complexity. In this book, multidisciplinary specialists explain the foundations and principles of tomographic imaging and describe a broad range of applications. The content is organized in five parts, which are dedicated to image reconstruction, microtomography, industrial tomography, morphological medical tomography and functional medical tomography.

Reconstruction en tomographie d'émission à photon unique par les techniques régularisantes de problèmes mal-posés

Download Reconstruction en tomographie d'émission à photon unique par les techniques régularisantes de problèmes mal-posés PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 316 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis Reconstruction en tomographie d'émission à photon unique par les techniques régularisantes de problèmes mal-posés by : Abdelaziz Laouar

Download or read book Reconstruction en tomographie d'émission à photon unique par les techniques régularisantes de problèmes mal-posés written by Abdelaziz Laouar and published by . This book was released on 1996 with total page 316 pages. Available in PDF, EPUB and Kindle. Book excerpt: CETTE THESE PRESENTE UNE ANALYSE DE LA RECONSTRUCTION D'IMAGES TOMOGRAPHIQUES D'EMISSION A PHOTON UNIQUE (SPECT) PAR UNE METHODE EXPERIMENTALE QUI PREND EN COMPTE LES PHENOMENES PHYSIQUES QUI JOUENT UN ROLE TRES IMPORTANT DANS LA DEGRADATION DES IMAGES SPECT. CETTE ANALYSE EST BASEE SUR LES TECHNIQUES DIRECTES DE RECONSTRUCTION. APRES AVOIR POSE LE PROBLEME DE LA RECONSTRUCTION TOMOGRAPHIQUE DE LA DISTRIBUTION RADIOACTIVE D'UN RADIOTRACEUR DANS UN VOLUME, NOUS PASSONS EN REVUE, DANS LA PREMIERE PARTIE, LES DIFFERENTES METHODES DE RECONSTRUCTIONS TOMOGRAPHIQUES, AINSI QUE LES PHENOMENES PHYSIQUES QUI DEGRADENT LES IMAGES SPECT, DONT LES DEUX PRINCIPAUX SONT LA DIFFUSION ET L'ATTENUATION DES PHOTONS. DANS LA SECONDE PARTIE, NOUS PROPOSONS UNE FORMULATION DE LA MODELISATION DE LA FORMATION DE L'IMAGE D'UN OBJET PAR UNE EQUATION INTEGRALE DE FREDHOLM DE PREMIERE ESPECE, DONT LE NOYAU DEPEND DE LA FONCTION DU SYSTEME. DANS LES CONDITIONS REELLES D'ACQUISITION EN MEDECINE NUCLEAIRE, CETTE FORMULATION REPRESENTE UN PROBLEME MAL-POSE. LE NOYAU DE CETTE EQUATION SOUS FORME DISCRETISEE CORRESPOND A CE NOUS AVONS APPELE MATRICE DE TRANSMISSION OU MATRICE SYSTEME. NOUS AVONS PROPOSE UNE METHODE EXPERIMENTALE POUR LA DETERMINATION DE CETTE MATRICE SYSTEME, PAR LE DEPLACEMENT D'UNE SOURCE RADIOACTIVE VOLUMIQUE DANS L'ESPACE OBJET ECHANTILLONNE A ETUDIER. CETTE APPROCHE PERMET DE PRENDRE EN COMPTE LA GLOBALITE DES PARAMETRES PHYSIQUES QUE SONT LA DIFFUSION, L'ATTENUATION ET LA NON UNIFORMITE DE LA REPONSE DU DETECTEUR. POUR LA RECONSTRUCTION DE NOS OBJETS, NOUS PROPOSONS QUATRE TECHNIQUES DE REGULARISATION DES PROBLEMES MAL-POSES: LA TRONCATURE PAR DECOMPOSITION EN VALEURS SINGULIERES (SVDT), LA TECHNIQUE DE TWOMEY-TIKHONOV, CELLE DE LANDWEBER ITERATIVE ET CELLE TWOMEY-TIKHONOV ITERATIVE ; LEURS SOLUTIONS SONT TOUTES EXPRIMEES DANS LA MEME BASE ORTHOGONALE SVD. DANS LA TROISIEME PARTIE, LA THESE EST CONSACREE A L'ANALYSE DES RECONSTRUCTIONS D'OBJETS TEST AVEC LA METHODE SVDT EN FONCTION DE DIFFERENTS PARAMETRES PHYSIQUES, TELS QUE LE NOMBRE D'INCIDENCES, DE FENETRES ENERGETIQUES, DE LIGNES DE LA MATRICE D'ACQUISITION, EN PRESENCE OU ABSENCE DE BRUIT ET DE MILIEU ABSORBANT. NOUS MONTRONS L'INFLUENCE DE CES PARAMETRES SUR LE MAUVAIS CONDITIONNEMENT DU PROBLEME MAL-POSE ET L'EFFET DE LA TRONCATURE PAR SVD SUR SON RECONDITIONNEMENT. ENFIN, UNE COMPARAISON QUALITATIVE ET QUANTITATIVE EST REALISEE ENTRE LES QUATRE TECHNIQUES REGULARISANTES PROPOSEES

QUANTIFICATION EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE

Download QUANTIFICATION EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 208 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis QUANTIFICATION EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE by : HAFIDA.. BERRAH

Download or read book QUANTIFICATION EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE written by HAFIDA.. BERRAH and published by . This book was released on 1993 with total page 208 pages. Available in PDF, EPUB and Kindle. Book excerpt: DANS LE BUT D'AMELIORER QUALITATIVEMENT ET QUANTITATIVEMENT LES IMAGES EN TOMOGRAPHIE D'EMISSION MONOPHOTONIQUE NOUS PROPOSONS DEUX CORRECTIONS DES PROJECTIONS AVANT RECONSTRUCTION: A) UNE NOUVELLE CORRECTION ANALYTIQUE D'ATTENUATION ET; B) UN FILTRE TRIDIMENSIONNEL UTILISANT LES PROPRIETES DE TRANSFORMATIONS DE FOURIER ET LES CORRELATIONS TRIDIMENSIONNELLES DES PROJECTIONS TOMOGRAPHIQUES. UNE METHODE DE CORRECTION D'ATTENUATION UTILISANT LES PROJECTIONS OPPOSEES D'EMISSION ET LA CARTE DES COEFFICIENTS D'ATTENUATION LINEAIRES OBTENUS PAR TRANSMISSION A ETE ETABLIE. LA VALIDATION DE LA METHODE PAR SIMULATION A ETE EFFECTUEE PAR LA QUANTIFICATION DES PROJECTIONS ET DES COUPES RECONSTRUITES PAR RETROPROJECTION FILTREE, EN PRESENCE ET EN L'ABSENCE DU BRUIT. UN FILTRE OPTIMAL DE FOURIER ETABLI EN TROIS DIMENSIONS EST PRESENTE. LES ETAPES DE SON ALGORITHME SONT LES SUIVANTES: 1) REARRANGEMENT GEOMETRIQUE DES DONNEES ACQUISES EN LINOGRAMMES; 2) OPTIMISATION DE LEUR ECHANTILLONNAGE PAR L'APPLICATION D'UNE TRANSFORMATION DE FOURIER DISCRETE BIDIMENSIONNELLE RAPIDE (TFDBR); 3) DECOMPOSITION EN SERIE DE FOURIER, SELON LE TROISIEME AXE PERIODISE, LIMITEE A UN NOMBRE APPROPRIE D'HARMONIQUE ET; 4) RETOUR A L'ESPACE DES LINOGRAMMES PAR LA TFDBR INVERSE. UN REARRANGEMENT EST EFFECTUE POUR REDONNER DES PROJECTIONS FILTREES

Implantation et évaluation d'une nouvelle méthode de reconstruction d'image en tomographie d'émission

Download Implantation et évaluation d'une nouvelle méthode de reconstruction d'image en tomographie d'émission PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (868 download)

DOWNLOAD NOW!


Book Synopsis Implantation et évaluation d'une nouvelle méthode de reconstruction d'image en tomographie d'émission by : Gilles Karcher

Download or read book Implantation et évaluation d'une nouvelle méthode de reconstruction d'image en tomographie d'émission written by Gilles Karcher and published by . This book was released on 1982 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: