Undulator A Diagnostics at the Advanced Photon Source

Download Undulator A Diagnostics at the Advanced Photon Source PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 34 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Undulator A Diagnostics at the Advanced Photon Source by :

Download or read book Undulator A Diagnostics at the Advanced Photon Source written by and published by . This book was released on 1998 with total page 34 pages. Available in PDF, EPUB and Kindle. Book excerpt: Diagnostics of Undulator A{number_sign}2 (UA2) radiation was performed during the October 1997 mn at the Advanced Photon Source (APS). The UA2 undulator is a standard 3.3-cm-period APS Undulator A, which was positioned downstream from the center of the straight section at Sector 8. The diagnostics included the angular-spectral measurements of the undulator radiation to determine the undulator radiation absolute spectral flux and the particle beam divergence. The results of the absolute spectral flux measurements are compared to the undulator spectrum calculated from measured undulator magnetic field. The particle's energy spread was determined from spectra comparison. Previously, the authors reported the first measurements made on Undulator A at the APS. The purpose of the present report is to summarize the results of the diagnostics performed on the Sector 8 undulator at the request of the IMM-CAT staff, and to present a more general discussion of undulator radiation sources at the APS and details of their diagnostics.

Diagnostics for the APS Undulator Test Line

Download Diagnostics for the APS Undulator Test Line PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 9 pages
Book Rating : 4.:/5 (873 download)

DOWNLOAD NOW!


Book Synopsis Diagnostics for the APS Undulator Test Line by :

Download or read book Diagnostics for the APS Undulator Test Line written by and published by . This book was released on 1993 with total page 9 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Status of the Advanced Photon Source Low-energy Undulator Test Line

Download Status of the Advanced Photon Source Low-energy Undulator Test Line PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 22 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Status of the Advanced Photon Source Low-energy Undulator Test Line by :

Download or read book Status of the Advanced Photon Source Low-energy Undulator Test Line written by and published by . This book was released on 1997 with total page 22 pages. Available in PDF, EPUB and Kindle. Book excerpt: The low-energy undulator test line (LEUTL) is being constructed at the Advanced Photon Source (APS). Its first purpose is to fully characterize innovative, future generation undulators, some of which may prove difficult or impossible to measure by traditional techniques. Second, LEUTL will act as a test line to investigate the generation of coherent radiation at wavelengths down to a few tens of nanometers. The line will use a high-brightness rf electron gun as its source and the APS linac to accelerate these electrons up to>650 MeV. This beam will then be directed into a new enclosure that is nearly 50 m long and will accommodate beamline components, diagnostics, and undulators. This region is wide enough to house two separate beamlines. In addition, there is an external end station appropriate for housing the equipment necessary to directly study the generated light outside of the radiation environment. At present, the new enclosure and building are complete, the new rf electron gun is installed and operational, and a part of the necessary transport line is installed. An undulator cell prototype, suitable for testing the requirements of single-pass free-electron laser operation, is near completion and will be installed during the winter shutdown of 1997. This paper will describe the LEUTL project and its capability for exploring the self-amplified spontaneous emission process.

Charged-particle Beam Diagnostics for the Advanced Photon Source (APS).

Download Charged-particle Beam Diagnostics for the Advanced Photon Source (APS). PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 17 pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Charged-particle Beam Diagnostics for the Advanced Photon Source (APS). by :

Download or read book Charged-particle Beam Diagnostics for the Advanced Photon Source (APS). written by and published by . This book was released on 1992 with total page 17 pages. Available in PDF, EPUB and Kindle. Book excerpt: Plans, prototypes, and initial test results for the charged-particle beam (e−, e) diagnostic systems on the injector rings, their transport lines, and the storage ring for the Advanced Photon Source (APS) are presented. The APS will be a synchrotron radiation user facility with one of the world's brightest x-ray sources in the 10-keV to 100-keV regime. Its 200-MeV electron linac, 450-MeV positron linac, positron accumulator ring, 7-GeV booster synchrotron, 7-GeV storage ring, and undulator test lines will also demand the development and demonstration of key particle-beam characterization techniques over a wide range of parameter space. Some of these parameter values overlap or approach those projected for fourth generation light sources (linac-driven FELs and high brightness storage rings) as described at a recent workshop. Initial results from the diagnostics prototypes on the linac test stand operating at 45-MeV include current monitor data, beam loss monitor data, and video digitization using VME architecture.

Overview of Charged-particle Beam Diagnostics for the Advanced Photon Source (APS).

Download Overview of Charged-particle Beam Diagnostics for the Advanced Photon Source (APS). PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 8 pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Overview of Charged-particle Beam Diagnostics for the Advanced Photon Source (APS). by :

Download or read book Overview of Charged-particle Beam Diagnostics for the Advanced Photon Source (APS). written by and published by . This book was released on 1992 with total page 8 pages. Available in PDF, EPUB and Kindle. Book excerpt: Plans, prototypes, and initial test results for the charged-particle beam (e−, e) diagnostic systems on the injector rings, their transport lines, and the storage ring for the Advanced Photon Source (APS) are presented. The APS will be a synchrotron radiation user facility with one of the world's brightest x-ray sources in the 10-keV to 100-keV regime. Its 200-MeV electron linac, 450-MeV positron linac, positron accumulator ring, 7-GeV booster synchrotron, 7-GeV storage ring, and undulator test lines will also demand the development and demonstration of key particle-beam characterization techniques over a wide range of parameter space. Some of these parameter values overlap or approach those projected for fourth generation light sources (linac-driven FELs and high brightness storage rings) as described at a recent workshop. Initial results from the diagnostics prototypes on the linac test stand operating at 45-MeV include current monitor data, beam loss monitor data, and video digitization using VME architecture.

Status of the APS Diagnostics Undulator Beamline

Download Status of the APS Diagnostics Undulator Beamline PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 4 pages
Book Rating : 4.:/5 (893 download)

DOWNLOAD NOW!


Book Synopsis Status of the APS Diagnostics Undulator Beamline by :

Download or read book Status of the APS Diagnostics Undulator Beamline written by and published by . This book was released on 1997 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt: We report the status of the diagnostics undulator beamline for the Advanced Photon Source (APS) storage ring. The beamline was designed for the characterization of the 7-GeV, low-emittance positron beam at high resolution. The special diagnostics undulator has been manufactured by STI Optronics. The device exhibits very low magnetic field errors at closed gap of 10.5 mm: first field integral less than 15 gauss·cm, and optical phase error less than 1.5°. The front end of the beamline and a monochromator are installed and tested for use on divergence and directional stability measurements with a target resolution of 3 [mu]rad utilizing the first harmonic radiation of 25 keV. Initial results for the divergence measurement show that the storage ring is operating well within its design goals.

Planned Optical Diagnostics for the APS Low-energy Undulator Test Line

Download Planned Optical Diagnostics for the APS Low-energy Undulator Test Line PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Planned Optical Diagnostics for the APS Low-energy Undulator Test Line by :

Download or read book Planned Optical Diagnostics for the APS Low-energy Undulator Test Line written by and published by . This book was released on 2001 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: At the Advanced Photon Source (APS), an alternate configuration of the injector linacs (low-energy undulator test line) using an rf gun as the source is projected to provide low, normalized emittance electron beams ([var-epsilon]n[approximately] 5[pi] mm mrad). In order to characterize such beams, the present intercepting Chromox screens with limited spatial resolution and temporal response are being complemented by optical transition radiation (OTR) screens at selected positions in the beamline to provide sub-100[micro]m spatial resolution and sub-ps response times. Both gated cameras and streak cameras will be used to measure the beam properties. Additionally, coherent transition radiation (CTR) and diffraction radiation (DR) based techniques will be evaluated. These beam characterizations will support self-amplified spontaneous emission (SASE) scaling experiments.

The Magnetic and Diagnostic Systems for the Advanced Photon Source Self-amplified Spontaneously Emitting FEL.

Download The Magnetic and Diagnostic Systems for the Advanced Photon Source Self-amplified Spontaneously Emitting FEL. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 24 pages
Book Rating : 4.:/5 (683 download)

DOWNLOAD NOW!


Book Synopsis The Magnetic and Diagnostic Systems for the Advanced Photon Source Self-amplified Spontaneously Emitting FEL. by :

Download or read book The Magnetic and Diagnostic Systems for the Advanced Photon Source Self-amplified Spontaneously Emitting FEL. written by and published by . This book was released on 1998 with total page 24 pages. Available in PDF, EPUB and Kindle. Book excerpt: A self-amplified spontaneously emitting (SASE) free-electron laser (FEL) for the visible-to-ultraviolet spectral range is under construction at the Advanced Photon Source at Argonne National Laboratory. The amplifier part of the FEL consists of twelve identical 2.7-meter-long sections. Each section includes a 2.4-meter-long, 33-mm-period hybrid undulator, a quadruple lens, and a set of electron beam and radiation diagnostics equipment. The undulatory will operate at a fixed magnetic gap (approx. 9.3 mm) with K=3.1. The electron beam position will be monitored using capacitive beam position monitors, YAG scintillators with imaging optics, and secondary emission detectors. The spatial distribution of the photon beam will be monitored by position sensitive detectors equipped with narrow-band filters. A high-resolution spectrograph will be used to observe the spectral distribution of the FEL radiation.

Initial Diagnostics Commissioning Results for the Advanced Photon Source (APS)

Download Initial Diagnostics Commissioning Results for the Advanced Photon Source (APS) PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 4 pages
Book Rating : 4.:/5 (929 download)

DOWNLOAD NOW!


Book Synopsis Initial Diagnostics Commissioning Results for the Advanced Photon Source (APS) by :

Download or read book Initial Diagnostics Commissioning Results for the Advanced Photon Source (APS) written by and published by . This book was released on 1995 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Results of Prototype Particle-beam Diagnostics Tests for the Advanced Photon Source (APS)

Download Results of Prototype Particle-beam Diagnostics Tests for the Advanced Photon Source (APS) PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 4 pages
Book Rating : 4.:/5 (929 download)

DOWNLOAD NOW!


Book Synopsis Results of Prototype Particle-beam Diagnostics Tests for the Advanced Photon Source (APS) by : Alexander Henderson Lumpkin

Download or read book Results of Prototype Particle-beam Diagnostics Tests for the Advanced Photon Source (APS) written by Alexander Henderson Lumpkin and published by . This book was released on 1993 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Preliminary Tests of the Optical Diagnostics for the APS Low-energy Undulator Test Line Particle Beam

Download Preliminary Tests of the Optical Diagnostics for the APS Low-energy Undulator Test Line Particle Beam PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 18 pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Preliminary Tests of the Optical Diagnostics for the APS Low-energy Undulator Test Line Particle Beam by :

Download or read book Preliminary Tests of the Optical Diagnostics for the APS Low-energy Undulator Test Line Particle Beam written by and published by . This book was released on 1997 with total page 18 pages. Available in PDF, EPUB and Kindle. Book excerpt: An alternate configuration of the injector linacs (low-energy undulator test line) at the Advanced Photon Source (APS) combined with a thermionic rf gun is projected to provide low, normalized emittance electron beams ({var_epsilon}{sub n} - 5% mm mrad). By using the electron linac and the inline, rephased positron linac, beam energies from 250 to 650 MeV with bunch lengths sigma?{sub t} - 1 ps are possible. In order to characterize such beams, the present intercepting Chromox screens with limited spatial resolution and temporal response are being complemented by optical transition radiation (OTR) screens at selected positions in the beamline to provide sub-100?m spatial resolution and sub-ps response times. Initial OTR images have been obtained from a beam at 650 MeV using the conventional thermionic gun to generate a 30-ns-long macropulse. Micropulse bunch lengths as short as 3 to 4 ps were also measured using a C5680 streak camera. Additionally, coherent transition radiation (CTR) and diffraction radiation (DR) based techniques will be evaluated. These beam characterizations will support self-amplified spontaneous emission (SASE) scaling experiments.

Ancestry of Benjamin W. Sammons

Download Ancestry of Benjamin W. Sammons PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (796 download)

DOWNLOAD NOW!


Book Synopsis Ancestry of Benjamin W. Sammons by :

Download or read book Ancestry of Benjamin W. Sammons written by and published by . This book was released on with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Photon Energy Tunability of Advanced Photon Source Undulators

Download Photon Energy Tunability of Advanced Photon Source Undulators PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Photon Energy Tunability of Advanced Photon Source Undulators by :

Download or read book Photon Energy Tunability of Advanced Photon Source Undulators written by and published by . This book was released on 1987 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: At a fixed storage ring energy, the energy of the harmonics of an undulator can be shifted or ''tuned'' by changing the magnet gap of the device. The possible photon energy interval spanned in this way depends on the undulator period, minimum closed gap, minimum acceptable photon intensity and storage ring energy. The minimum magnet gap depends directly on the stay clear particle beam aperture required for storage ring operation. The tunability of undulators planned for the Advanced Photon Source with first harmonic photon energies in the range of 5 to 20 keV are discussed. The results of an analysis used to optimize the APS ring energy is presented and tunability contours and intensity parameters are presented for two typical classes of devices.

Design and Analysis of a Be Window for the APS Diagnostics Undulator Beamline

Download Design and Analysis of a Be Window for the APS Diagnostics Undulator Beamline PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 4 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Design and Analysis of a Be Window for the APS Diagnostics Undulator Beamline by :

Download or read book Design and Analysis of a Be Window for the APS Diagnostics Undulator Beamline written by and published by . This book was released on 1997 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt: The design of a beryllium (Be) window for use under the extremely high heat load of an undulator beam is one of the challenges for third-generation synchrotron radiation beamlines. A novel design of a Be window is presented for the Advanced Photon Source (APS) diagnostics undulator beamline, whose beam has a peak power density of 150 W/mm2 (7 GeV/100 mA stored beam). The window has a double concave profile with a thickness of 0.5 mm at the center and is brazed to a water-cooled oxygen-free, high-conductivity (OFHC) copper manifold. Finite-element thermal analysis of the Be window is also presented.

Energy Research Abstracts

Download Energy Research Abstracts PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 782 pages
Book Rating : 4.3/5 (129 download)

DOWNLOAD NOW!


Book Synopsis Energy Research Abstracts by :

Download or read book Energy Research Abstracts written by and published by . This book was released on 1995 with total page 782 pages. Available in PDF, EPUB and Kindle. Book excerpt:

INIS Atomindex

Download INIS Atomindex PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 640 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis INIS Atomindex by :

Download or read book INIS Atomindex written by and published by . This book was released on 1995 with total page 640 pages. Available in PDF, EPUB and Kindle. Book excerpt:

The Advanced Photon Source Low-energy Undulator Test Line

Download The Advanced Photon Source Low-energy Undulator Test Line PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 4 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis The Advanced Photon Source Low-energy Undulator Test Line by :

Download or read book The Advanced Photon Source Low-energy Undulator Test Line written by and published by . This book was released on 1997 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt: There are a number of fully commissioned 3rd-generation synchrotron light sources in the world today. So far they have met the demanding requirements of the user community; however, there is always a desire to go beyond what is presently available or even desirable. The Advanced Photon Source (APS) Low-Energy Undulator Test Line (LEUTL) was conceived to address the advancement of synchrotron light sources. The LEUTL uses the existing APS linac and a low-emittance electron gun, and by means of measurements of the beam and generated light, will test new and innovative undulators and push the technology and physics of single-pass, coherent light sources. The design and status of the LEUTL will be described along with its immediate capabilities and those planned for the future.