The CDF Silicon Vertex Detector for Run II.

Download The CDF Silicon Vertex Detector for Run II. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis The CDF Silicon Vertex Detector for Run II. by :

Download or read book The CDF Silicon Vertex Detector for Run II. written by and published by . This book was released on 2004 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The 8 layer, 720k channel CDF Run II silicon detector is an essential part of the heavy flavor tagging and forward tracking capabilities of the CDF experiment. A summary of the experience in commissioning and operating this double-sided detector during the first 2 years of Run II is presented. The performances of the silicon in term of resolution, efficiency are also described. The results of the studies of radiation damage and the expected operational limits are discussed. A short description of the SVT, the Level 2 Silicon Vertex Trigger, one of the major upgrades related to the new silicon device is also presented. Finally, some of the many physics results achieved by means of the new Silicon+SVT machinery are also reviewed.

Operational Experience, Improvements, and Performance of the CDF Run II Silicon Vertex Detector

Download Operational Experience, Improvements, and Performance of the CDF Run II Silicon Vertex Detector PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 29 pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Operational Experience, Improvements, and Performance of the CDF Run II Silicon Vertex Detector by :

Download or read book Operational Experience, Improvements, and Performance of the CDF Run II Silicon Vertex Detector written by and published by . This book was released on 2013 with total page 29 pages. Available in PDF, EPUB and Kindle. Book excerpt:

The SVX II Silicon Vertex Detector at CDF.

Download The SVX II Silicon Vertex Detector at CDF. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 6 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis The SVX II Silicon Vertex Detector at CDF. by :

Download or read book The SVX II Silicon Vertex Detector at CDF. written by and published by . This book was released on 1996 with total page 6 pages. Available in PDF, EPUB and Kindle. Book excerpt: The CDF silicon vertex detector is being upgraded for use in Run II of the Fermilab collider. The increased luminosity in Run II, coupled with the desire for increased acceptance and secondary vertex triggering, necessitates a complete redesign of the previous generation tracker. Details of the design are described.

The CDF SVX II Detector Upgrade

Download The CDF SVX II Detector Upgrade PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 8 pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis The CDF SVX II Detector Upgrade by :

Download or read book The CDF SVX II Detector Upgrade written by and published by . This book was released on 1993 with total page 8 pages. Available in PDF, EPUB and Kindle. Book excerpt: The proposed CDF SVX II detector upgrade for secondary vertex detection during the Fermilab Tevatron Run II collider run is described. The general design and important features of this silicon vertex detector are presented. The CDF physics goals which are addressed by this detector are also given.

The CDF Silicon Vertex Detector SVX and Its Upgrades

Download The CDF Silicon Vertex Detector SVX and Its Upgrades PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 16 pages
Book Rating : 4.:/5 (873 download)

DOWNLOAD NOW!


Book Synopsis The CDF Silicon Vertex Detector SVX and Its Upgrades by :

Download or read book The CDF Silicon Vertex Detector SVX and Its Upgrades written by and published by . This book was released on 1994 with total page 16 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Landwirtschaft und Landwirtschaftskammer Weser-Ems

Download Landwirtschaft und Landwirtschaftskammer Weser-Ems PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 12 pages
Book Rating : 4.:/5 (247 download)

DOWNLOAD NOW!


Book Synopsis Landwirtschaft und Landwirtschaftskammer Weser-Ems by :

Download or read book Landwirtschaft und Landwirtschaftskammer Weser-Ems written by and published by . This book was released on 1989 with total page 12 pages. Available in PDF, EPUB and Kindle. Book excerpt:

SVX II a Silicon Vertex Detector for Run II of the Tevatron

Download SVX II a Silicon Vertex Detector for Run II of the Tevatron PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 17 pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis SVX II a Silicon Vertex Detector for Run II of the Tevatron by :

Download or read book SVX II a Silicon Vertex Detector for Run II of the Tevatron written by and published by . This book was released on 1994 with total page 17 pages. Available in PDF, EPUB and Kindle. Book excerpt: A microstrip silicon detector SVX II has been proposed for the upgrade of the vertex detector of the CDF experiment to be installed for run II of the Tevatron in 1998. Three barrels of four layers of double sided detectors will cover the interaction region. The requirement of the silicon tracker and the specification of the sensors are discussed together with the proposed R & D to verify the performance of the prototypes detectors produced by Sintef, Micron and Hamamatsu.

Status of the CDF Run II Silicon Detector

Download Status of the CDF Run II Silicon Detector PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 358 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Status of the CDF Run II Silicon Detector by :

Download or read book Status of the CDF Run II Silicon Detector written by and published by . This book was released on 2003 with total page 358 pages. Available in PDF, EPUB and Kindle. Book excerpt: A snapshot of the status of the CDF Run II Silicon Detector is presented, with a summary of commissioning issues since the start of Run II, current performance of the detector, and the use of the data in both the trigger and offline reconstruction.

Status and Performance of the CDF Run II Silicon Detectors

Download Status and Performance of the CDF Run II Silicon Detectors PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 6 pages
Book Rating : 4.:/5 (682 download)

DOWNLOAD NOW!


Book Synopsis Status and Performance of the CDF Run II Silicon Detectors by :

Download or read book Status and Performance of the CDF Run II Silicon Detectors written by and published by . This book was released on 2004 with total page 6 pages. Available in PDF, EPUB and Kindle. Book excerpt: In 2001, an upgraded silicon detector system was installed in the CDF II experiment on the Tevatron at Fermilab. The complete system consists of three silicon microstrip detectors: SVX II with five layers for precision tracking, Layer 00 with one beampipe-mounted layer for vertexing, and two Intermediate Silicon Layers located between SVX II and the main CDF II tracking chamber. Currently all detectors in the system are operating at or near design levels. The performance of the combined silicon system is excellent in the context of CDF tracking algorithms, and the first useful physics results from the innermost Layer 00 detector have been recently documented. Operational and monitoring efforts have also been strengthened to maintain silicon efficiency through the end of Run 2 at the Tevatron.

The CDF Silicon Vertex Detector

Download The CDF Silicon Vertex Detector PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 21 pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis The CDF Silicon Vertex Detector by :

Download or read book The CDF Silicon Vertex Detector written by and published by . This book was released on 1993 with total page 21 pages. Available in PDF, EPUB and Kindle. Book excerpt: A silicon strip vertex detector was designed, constructed and commissioned at the CDF experiment at the Tevatron collider at Fermilab. The mechanical design of the detector, its cooling and monitoring are presented. The front end electronics employing a custom VLSI chip, the readout electronics and various components of the SVX system are described. The system performance and the experience with the operation of the detector in the radiation environment are discussed. The device has been taking colliding beams data since May of 1992, performing at its best design specifications and enhancing the physics program of CDF.

The Run IIb Upgrade of the CDF Silicon Detectors

Download The Run IIb Upgrade of the CDF Silicon Detectors PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis The Run IIb Upgrade of the CDF Silicon Detectors by :

Download or read book The Run IIb Upgrade of the CDF Silicon Detectors written by and published by . This book was released on 2002 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: A substantial portion of the Run IIa silicon detectors of the CDF experiment will not perform adequately for the duration of Run IIb (15 fb−1) because of radiation damage. The Silicon Vertex Detector (SVX-II) and Layer 00 will be fully replaced at the end of Run IIa. The Run IIb silicon tracker has a baseline design that safely achieves the required radiation tolerance by using single sided sensors that are actively cooled. The new Run IIb castellated layout contains more silicon surface area and has a more uniform radial distribution. It minimizes the number of hybrid and sensor varieties providing quick construction and assembly. The total mass in the tracking volume is reduced by eliminating unnecessary the passive material from the CDF volume.

Mechanical Design of the CDF SVX II Silicon Vertex Detector

Download Mechanical Design of the CDF SVX II Silicon Vertex Detector PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 6 pages
Book Rating : 4.:/5 (682 download)

DOWNLOAD NOW!


Book Synopsis Mechanical Design of the CDF SVX II Silicon Vertex Detector by :

Download or read book Mechanical Design of the CDF SVX II Silicon Vertex Detector written by and published by . This book was released on 1994 with total page 6 pages. Available in PDF, EPUB and Kindle. Book excerpt: A next generation silicon vertex detector is planned at CDF for the 1998 Tevatron collider run with the Main Injector. The SVX II silicon vertex detector will allow high luminosity data-taking, enable online triggering of secondary vertex production, and greatly increase the acceptance for heavy flavor physics at CDF. The design specifications, geometric layout, and early mechanical prototyping work for this detector are discussed.

Status and Performance of the CDF Run 2 Silicon Detectors

Download Status and Performance of the CDF Run 2 Silicon Detectors PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (316 download)

DOWNLOAD NOW!


Book Synopsis Status and Performance of the CDF Run 2 Silicon Detectors by : Jason Nielsen

Download or read book Status and Performance of the CDF Run 2 Silicon Detectors written by Jason Nielsen and published by . This book was released on 2004 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: In 2001, an upgraded silicon detector system was installed in the CDF II experiment on the Tevatron at Fermilab. The complete system consists of three silicon micro-strip detectors: SVX II with five layers for precision tracking, Layer 00 with one beampipe-mounted layer for vertexing, and two Intermediate Silicon Layers located between SVX II and the main CDF II tracking chamber. Currently all detectors in the system are operating at or near design levels. The performance of the combined silicon system is excellent in the context of CDF tracking algorithms, and the first useful physics results from the innermost Layer 00 detector have been recently documented. Operational and monitoring efforts have also been strengthened to maintain silicon efficiency through the end of Run 2 at the Tevatron.

Double-sided Silicon Microstrip Sensors for the CDF SVX II Detector

Download Double-sided Silicon Microstrip Sensors for the CDF SVX II Detector PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 7 pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis Double-sided Silicon Microstrip Sensors for the CDF SVX II Detector by :

Download or read book Double-sided Silicon Microstrip Sensors for the CDF SVX II Detector written by and published by . This book was released on 1994 with total page 7 pages. Available in PDF, EPUB and Kindle. Book excerpt: The SVX II is the planned third-generation silicon vertex detector in the Collider Detector at Fermilab. Now in the prototyping phase, it is scheduled for operation in Tevatron Run II. This document describes aspects of the detector related to the design of the silicon microstrip sensors.

The CDF Online Silicon Vertex Tracker

Download The CDF Online Silicon Vertex Tracker PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis The CDF Online Silicon Vertex Tracker by :

Download or read book The CDF Online Silicon Vertex Tracker written by and published by . This book was released on 2001 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The CDF Online Silicon Vertex Tracker reconstructs 2-D tracks by linking hit positions measured by the Silicon Vertex Detector to the Central Outer Chamber tracks found by the eXtremely Fast Tracker. The system has been completely built and assembled and it is now being commissioned using the first CDF run II data. The precision measurement of the track impact parameter will allow triggering on B hadron decay vertices and thus investigating important areas in the B sector, like CP violation and B{sub s} mixing. In this paper we briefly review the architecture and the tracking algorithms implemented in the SVT and we report on the performance of the system achieved in the early phase of CDF run II.

Operation and Performance of the Silicon Vertex Detector (SVX') at CDF.

Download Operation and Performance of the Silicon Vertex Detector (SVX') at CDF. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis Operation and Performance of the Silicon Vertex Detector (SVX') at CDF. by :

Download or read book Operation and Performance of the Silicon Vertex Detector (SVX') at CDF. written by and published by . This book was released on 2005 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The authors describe the operation and performance of the Silicon Vertex Detector (SVX'), which replaced the CDF SVX detector for run lb of the Fermilab Tevatron Collider. The new features of the SVX' include AC coupled readout, Field OXide Field Effect Transistor (FOXFET) biasing and radiation hard front end electronics. The authors expect the detector to survive beyond the 100 pb[sup -1] of data taking anticipated for the present CDF physics run. Preliminary results from the collider data show that the detector has a resolution of about 12 [mu]m. This provides a powerful tool to do top and bottom physics.

Status and Performance of the CDF Run II Silicon Detector

Download Status and Performance of the CDF Run II Silicon Detector PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 4 pages
Book Rating : 4.:/5 (316 download)

DOWNLOAD NOW!


Book Synopsis Status and Performance of the CDF Run II Silicon Detector by : A. Boveia

Download or read book Status and Performance of the CDF Run II Silicon Detector written by A. Boveia and published by . This book was released on 2005 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt: The CDF Run II silicon detector with its 8 layers of double- and single-sided silicon microstrip sensors and a total 722,432 readout channels is one of the largest silicon detector devices currently in use by a HEP experiment. We report our experience commissioning and operating this complex device during the first 4 years of Run II. As the luminosity delivered by the Tevatron increases, we have observed measurable effects of radiation damage in studies of charge collection and noise versus applied bias voltage at many different integrated luminosities. We discuss these studies and their impact on the expected lifetime of the detector.