Read Books Online and Download eBooks, EPub, PDF, Mobi, Kindle, Text Full Free.
Testing Of Small And Large Sign Support Systems Foil Test Number 92f011
Download Testing Of Small And Large Sign Support Systems Foil Test Number 92f011 full books in PDF, epub, and Kindle. Read online Testing Of Small And Large Sign Support Systems Foil Test Number 92f011 ebook anywhere anytime directly on your device. Fast Download speed and no annoying ads. We cannot guarantee that every ebooks is available!
Download or read book Achievement Report written by and published by . This book was released on 1994 with total page 42 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book Highway Research Abstracts written by and published by . This book was released on 1994 with total page 1006 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Government reports annual index by :
Download or read book Government reports annual index written by and published by . This book was released on 199? with total page 1686 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Government Reports Announcements & Index by :
Download or read book Government Reports Announcements & Index written by and published by . This book was released on 1994 with total page 604 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Book Synopsis Testing of Small and Large Sign Support Systems FOIL Test Number 92F011 by : Christopher M. Brown
Download or read book Testing of Small and Large Sign Support Systems FOIL Test Number 92F011 written by Christopher M. Brown and published by . This book was released on 1994 with total page 16 pages. Available in PDF, EPUB and Kindle. Book excerpt: "This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92FOll. The vehicle used for these test was a 1985 Honda Civic. The purpose of this test was to evaluate the low-speed safety performance of a dual 4-1b/ft (6-kg/m) u-channel sign support with a 5-in (127-mm) overlap splice in weak soil. The performance evaluation was based on the latest requirements for breakaway supports as specified in Volume 54, Number 3 of the Federal Register dated January 5, 1989. These criteria specify, in part, that the occupant change in velocity must be 16 ft/s (4.9 m/s) or less, that the significant test article stub height remaining after impact be no more than 4 in (102 mm), and that there can be no occupant compartment intrusion. The test results indicate that the dual 4-1b/ft (6-kg/m) u-channel sign support with a 5-in (127-mrn) overlap splice does not meet all of the applicable performance criteria for roadside safety appurtenances in weak soil specified by the FHWA"--Technical report documentation page.