Status of the Linac Coherent Light Source

Download Status of the Linac Coherent Light Source PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 5 pages
Book Rating : 4.:/5 (873 download)

DOWNLOAD NOW!


Book Synopsis Status of the Linac Coherent Light Source by :

Download or read book Status of the Linac Coherent Light Source written by and published by . This book was released on 2011 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Linac Coherent Light Source (LCLS) is a free electron laser facility in construction at Stanford Linear Accelerator Center. It is designed to operate in the wavelength range 0.15-1.5 nanometers. At the time of this conference, civil construction of new tunnels and buildings is complete, the necessary modifications to the SLAC linac are complete, and the undulator system and x-ray optics/diagnostics are being installed. The electron gun, 135 MeV injector linac and 250 MeV bunch compressor were commissioned in 2007. Accelerator commissioning activities are presently devoted to the achievement of performance goals for the completed 14 GeV linac.

Linac Coherent Light Source - Status and Prospects

Download Linac Coherent Light Source - Status and Prospects PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 11 pages
Book Rating : 4.:/5 (316 download)

DOWNLOAD NOW!


Book Synopsis Linac Coherent Light Source - Status and Prospects by : John N. Galayda

Download or read book Linac Coherent Light Source - Status and Prospects written by John N. Galayda and published by . This book was released on 2005 with total page 11 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Linac Coherent Light Source (LCLS) Project will be an x-ray free-electron laser. It is intended to produce pulses of 800-8,000 eV photons. Each pulse, produced with a repetition frequency of up to 120 Hz, will provide>10{sup 12} photons within a duration of less than 200 femtoseconds. The project employs the last kilometer of the SLAC linac to provide a low-emittance electron beam in the energy range 4-14 GeV to a single undulator. Two experiment halls, located 100m and 350m from the undulator exit, will house six experiment stations for research in atomic/molecular physics, pump-probe dynamics of materials and chemical processes, x-ray imaging of clusters and complex molecules, and plasma physics. Engineering design activities began in 2003, and the project is to be completed in March 2009. The project design permits straightforward expansion of the LCLS to multiple undulators.

LCLS

Download LCLS PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (539 download)

DOWNLOAD NOW!


Book Synopsis LCLS by :

Download or read book LCLS written by and published by . This book was released on 2002 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

The Linac Coherent Light Source Project at SLAC.

Download The Linac Coherent Light Source Project at SLAC. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (94 download)

DOWNLOAD NOW!


Book Synopsis The Linac Coherent Light Source Project at SLAC. by :

Download or read book The Linac Coherent Light Source Project at SLAC. written by and published by . This book was released on 2007 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser project presently under construction at SLAC. A 14-GeV high-brightness electron beam is produced in the last kilometer of the existing SLAC linear accelerator, generating coherent x-ray radiation in a 130-m long undulator. The peak x-ray brightness is 10 orders of magnitude higher than existing 3rd generation light sources with a wavelength of 1.5 Angstroms and a pulse duration as short as one femtosecond, opening limitless scientific opportunities in the world of the ultra-small and ultra-fast. This presentation will describe the project scope and status, highlighting especially the key accelerator physics challenges.

Linac Coherent Light Source (LCLS) Design Study Report

Download Linac Coherent Light Source (LCLS) Design Study Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 300 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Linac Coherent Light Source (LCLS) Design Study Report by :

Download or read book Linac Coherent Light Source (LCLS) Design Study Report written by and published by . This book was released on 1998 with total page 300 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Stanford Linear Accelerator Center (SLAC), in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the self-amplified spontaneous emission (SASE) mode in the wavelength range 1.5--15 Å. This FEL, called Linac Coherent Light Source (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. In this report, the Design Team has established performance parameters for all the major components of the LCLS and developed a layout of the entire system. Chapter 1 is the Executive Summary. Chapter 2 (Overview) provides a brief description of each of the major sections of the LCLS, from the rf photocathode gun, through the experimental stations and electron beam dump. Chapter 3 describes the scientific case for the LCLS. Chapter 4 provides a review of the principles of the FEL physics that the LCLS is based on, and Chapter 5 discusses the choice of the system's physical parameters. Chapters 6 through 10 describe in detail each major element of the system. Chapters 11 through 13 respectively cover undulator controls, mechanical alignment, and radiation issues.

Research and Development Toward a 4.5-1.5 Å Linac Coherent Light Source (LCLS) at SLAC.

Download Research and Development Toward a 4.5-1.5 Å Linac Coherent Light Source (LCLS) at SLAC. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 29 pages
Book Rating : 4.:/5 (871 download)

DOWNLOAD NOW!


Book Synopsis Research and Development Toward a 4.5-1.5 Å Linac Coherent Light Source (LCLS) at SLAC. by :

Download or read book Research and Development Toward a 4.5-1.5 Å Linac Coherent Light Source (LCLS) at SLAC. written by and published by . This book was released on 1995 with total page 29 pages. Available in PDF, EPUB and Kindle. Book excerpt: In recent years significant studies have been initiated on the feasibility of utilizing a portion of the 3km S-band accelerator at SLAC to drive a short wavelength (4.5-1.5 A) Linac Coherent Light Source (LCLS), a Free Electron Laser (FEL) operating in the Self- Amplified Spontaneous Emission (SASE) regime. Electron beam requirements for single-pass saturation in a minimal time include: (1) a peak current in the 7 kA range, (2) a relative energy spread of>0.05%, and (3) a transverse emittance, [epsilon][r-m], approximating the diffraction limit condition [epsilon] = [lambda] / 4[pi], where lambda(m) is the output wavelength. Requirements on the insertion device include field error levels of 0.02% for keeping the electron bunch centered on and in phase with the amplified photons, and a focusing beta of 8 m/rad for inhibiting the dilution of its transverse density. Although much progress has been made in developing individual components and beam processing techniques necessary for LCLS operation down to approx. 20 A, a substantial amount of research and development is still required in a number of theoretical and experimental areas leading to the construction and operation of a 4.5-1.5 A LCLS. In this paper we report on a research and development program underway and in planning at SLAC for addressing critical questions in these areas.

Research and Development Toward a 4.5-1.5[Angstrom] Linac Coherent Light Source (LCLS) at SLAC.

Download Research and Development Toward a 4.5-1.5[Angstrom] Linac Coherent Light Source (LCLS) at SLAC. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Research and Development Toward a 4.5-1.5[Angstrom] Linac Coherent Light Source (LCLS) at SLAC. by :

Download or read book Research and Development Toward a 4.5-1.5[Angstrom] Linac Coherent Light Source (LCLS) at SLAC. written by and published by . This book was released on 2001 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: In recent years significant studies have been initiated on the feasibility of utilizing a portion of the 3km S-band accelerator at SLAC to drive a short wavelength (4.5-1.5 A) Linac Coherent Light Source (LCLS), a Free Electron Laser (FEL) operating in the Self- Amplified Spontaneous Emission (SASE) regime. Electron beam requirements for single-pass saturation in a minimal time include: (1) a peak current in the 7 kA range, (2) a relative energy spread of[lt]0.05%, and (3) a transverse emittance, [epsilon][r-m], approximating the diffraction limit condition[epsilon]=[lambda] / 4[pi], where lambda(m) is the output wavelength. Requirements on the insertion device include field error levels of 0.02% for keeping the electron bunch centered on and in phase with the amplified photons, and a focusing beta of 8 m/rad for inhibiting the dilution of its transverse density. Although much progress has been made in developing individual components and beam processing techniques necessary for LCLS operation down to approx. 20 A, a substantial amount of research and development is still required in a number of theoretical and experimental areas leading to the construction and operation of a 4.5-1.5 A LCLS. In this paper we report on a research and development program underway and in planning at SLAC for addressing critical questions in these areas.

The Linac Coherent Light Source

Download The Linac Coherent Light Source PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 5 pages
Book Rating : 4.:/5 (925 download)

DOWNLOAD NOW!


Book Synopsis The Linac Coherent Light Source by :

Download or read book The Linac Coherent Light Source written by and published by . This book was released on 2015 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory was the first hard X-ray free-electron laser (FEL) to operate as a user facility. After five years of operation, LCLS is now a mature FEL user facility. Our personal views about opportunities and challenges inherent to these unique light sources are discussed.

Prospects for High Power Linac Coherent Light Source (LCLS) Development in the 1000Å - 1Å Wavelength Range

Download Prospects for High Power Linac Coherent Light Source (LCLS) Development in the 1000Å - 1Å Wavelength Range PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 10 pages
Book Rating : 4.:/5 (873 download)

DOWNLOAD NOW!


Book Synopsis Prospects for High Power Linac Coherent Light Source (LCLS) Development in the 1000Å - 1Å Wavelength Range by :

Download or read book Prospects for High Power Linac Coherent Light Source (LCLS) Development in the 1000Å - 1Å Wavelength Range written by and published by . This book was released on 1994 with total page 10 pages. Available in PDF, EPUB and Kindle. Book excerpt: Electron bunch requirements for single-pass saturation of a Free-Electron Laser (FEL) operating at full transverse coherence in the Self-Amplified Spontaneous Emission (SASE) mode include: (1) a high peak current, (2) a sufficiently low relative energy spread, and (3) a transverse emittance {var_epsilon}[r-m] satisfying the condition {var_epsilon} ≤ [lambda]A/4[pi], where [lambda][m] is the output wavelength of the FEL. In the insertion device that induces the coherent amplification, the prepared electron bunch must be kept on a trajectory sufficiently collinear with the amplified photons without significant dilution of its transverse density. In this paper we discuss a Linac Coherent Light Source (LCLS) based on a high energy accelerator such as, e.g., the 3km S-band structure at the Stanford Linear Accelerator Center (SLAC), followed by a long high-precision undulator with superimposed quadrupole (FODO) focusing, to fulfill the given requirements for SASE operation in the 1000Å--1Å range. The electron source for the linac, an RF gun with a laser-excited photocathode featuring a normalized emittance in the 1--3 mm-mrad range, a longitudinal bunch duration of the order of 3 ps, and approximately 10−9 C/bunch, is a primary determinant of the required low transverse and longitudinal emittances. Acceleration of the injected bunch to energies in the 5--25 GeV range is used to reduce the relative longitudinal energy spread in the bunch, as well as to reduce the transverse emittance to values consistent with the cited wavelength regime. Two longitudinal compression stages are employed to increase the peak bunch current to the 2--5 kA levels required for sufficiently rapid saturation. The output radiation is delivered, via a grazing-incidence mirror bank, to optical instrumentation and a multi-user beam line system. Technological requirements for LCLS operation at 40Å, 4.5Å, and 1.5Å are examined.

Linac Coherent Light Source II (LCLS-II) Conceptual Design Report

Download Linac Coherent Light Source II (LCLS-II) Conceptual Design Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (873 download)

DOWNLOAD NOW!


Book Synopsis Linac Coherent Light Source II (LCLS-II) Conceptual Design Report by :

Download or read book Linac Coherent Light Source II (LCLS-II) Conceptual Design Report written by and published by . This book was released on 2011 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The LCLS-II Project is designed to support the DOE Office of Science mission, as described in the 22 April 2010 Mission Need Statement. The scope of the Project was chosen to provide an increase in capabilities and capacity for the facility both at project completion in 2017 and in the subsequent decade. The Project is designed to address all points of the Mission Need Statement (MNS): (1) Expanded spectral reach; (2) Capability to provide x-ray beams with controllable polarization; (3) Capability to provide 'pump' pulses over a vastly extended range of photon energies to a sample, synchronized to LCLS-II x-ray probe pulses with controllable inter-pulse time delay; and (4) Increase of user access through parallel rather than serial x-ray beam use within the constraint of a $300M-$400M Total Project Cost (TPC) range. The LCLS-II Project will construct: (1) A hard x-ray undulator source (2-13 keV); (2) A soft x-ray undulator source (250-2,000 eV); (3) A dedicated, independent electron source for these new undulators, using sectors 10-20 of the SLAC linac; (4) Modifications to existing SLAC facilities for the injector and new shielded enclosures for the undulator sources, beam dumps and x-ray front ends; (5) A new experiment hall capable of accommodating four experiment stations; and (6) Relocation of the two soft x-ray instruments in the existing Near Experiment Hall (NEH) to the new experiment hall (Experiment Hall-II). A key objective of LCLS-II is to maintain near-term international leadership in the study of matter on the fundamental atomic length scale and the associated ultrafast time scales of atomic motion and electronic transformation. Clearly, such studies promise scientific breakthroughs in key areas of societal needs like energy, environment, health and technology, and they are uniquely enabled by forefront X-ray Free Electron Laser (X-FEL) facilities. While the implementation of LCLS-II extends to about 2017, it is important to realize that LCLS-II only constitutes a stepping stone to what we believe is needed over a longer time scale. At present, a practical time horizon for planning is about 15 years into the future, matching that of worldwide planning activities for competitive X-FEL facilities in Europe and Asia. We therefore envision LCLS-II as an important stage in development to what is required by about 2025, tentatively called LCLS-2025, for continued US leadership even as new facilities around the world are being completed. We envision LCLS primarily as a hard x-ray FEL facility with some soft x-ray capabilities. A survey of planned X-FEL facilities around the world suggests that US planning to 2025 needs to include an internationally competitive soft x-ray FEL facility which complements the LCLS plans outlined in this document.

Linac Coherent Light Source (LCLS) at 2--4 Nm Using the SLAC Linac

Download Linac Coherent Light Source (LCLS) at 2--4 Nm Using the SLAC Linac PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis Linac Coherent Light Source (LCLS) at 2--4 Nm Using the SLAC Linac by :

Download or read book Linac Coherent Light Source (LCLS) at 2--4 Nm Using the SLAC Linac written by and published by . This book was released on 2005 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The authors describe the possible use of the SLAC linac to drive a unique, powerful, short wavelength Linac Coherent Light Source (LCLS). Using the FEL principle, lasing is achieved in a single pass of a high peak current electron beam through a long undulator by self-amplified-spontaneous-emission (SASE). The main components are a high-brightness electron RF gun with a photocathode, two electron bunch length compressors, the existing SLAC linac, beam diagnostics, and a long undulator combined with a FODO quadrupole focusing system. The RF gun, to be installed about 1 km from the end of the SLAC linac, would produce a single bunch of 6 x 10[sup 9] electrons with an invariant emittance of about 3 mm-mrad and a bunch length of about 500 [mu]m. That bunch is then accelerated to 100 MeV and compressed to a length of about 200 [mu]m. The main SLAC linac accelerates the bunch to 2 GeV were a second bunch compressor reduces the length to 30--40 [mu]m and produces a peak current of 2--3 kA. The bunch is then accelerated to 7--8 GeV and transported to a 50--70 m long undulator. Using electrons below 8 GeV, the undulator could operate at wavelengths down to 2 nm, producing about 10 GW peak power in sub-ps light pulses. At a linac repetition rate of 120 Hz, the average power is about 1 W. Linac operation at lower beam energies provides longer wavelength radiation. After the undulator, the beam is deposited in a dump. The LCLS light pulses are then distributed to multiple user stations using grazing incident mirrors. Length compression, emittance control, phase stability, FEL design criteria, and parameter tolerances are discussed. A demonstration experiment is also described which uses the SLAC linac and (possibly) the PALADIN undulator to study SASE to power saturation at wavelengths of 40--360 nm.

Assessment of the Results of External Independent Reviews for U.S. Department of Energy Projects

Download Assessment of the Results of External Independent Reviews for U.S. Department of Energy Projects PDF Online Free

Author :
Publisher : National Academies Press
ISBN 13 : 0309106397
Total Pages : 74 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Assessment of the Results of External Independent Reviews for U.S. Department of Energy Projects by : National Research Council

Download or read book Assessment of the Results of External Independent Reviews for U.S. Department of Energy Projects written by National Research Council and published by National Academies Press. This book was released on 2007-05-10 with total page 74 pages. Available in PDF, EPUB and Kindle. Book excerpt: Peer review is an essential component of engineering practice and other scientific and technical undertakings. Peer reviews are conducted to ensure that activities are technically adequate, competently performed, and properly documented; to validate assumptions, calculations, and extrapolations; and to assess alternative interpretations, methodologies, acceptance criteria, and other aspects of the work products and the documentation that support them. Effective peer reviews are conducted in an environment of mutual respect, recognizing the contributions of all participants. Their primary objective is to help the project team achieve its goals. Reviews also contribute to quality assurance, risk management, and overall improvement of the management process. The U.S. Department of Energy (DOE) conducts different types of peer reviews at the different stages of a project, including reviews to assess risks and other factors related to design, safety, cost estimates, value engineering, and project management. Independent project reviews (IPRs) are conducted by federal staff not directly affiliated with the project or program and management and operations (M&O) contractors. External independent reviews (EIRs) are overseen by the Office of Engineering and Construction Management and conducted by contractors external to the department. EIRs are the primary focus of this report. However, the committee found that, in many cases, IPRs are explicitly used as preparation for or as preliminary reviews prior to EIRs. Thus, because IPRs are integral to the review process in DOE, they are also discussed because they might have an effect on EIRs. In October 2000, DOE issued Order 413.3, Program and Project Management for the Acquisition of Capital Assets (DOE, 2000). The order established a series of five critical decisions (CDs), or major milestones, that require senior management review and approval to ensure that a project satisfies applicable mission, design, security, and safety requirements: approve mission need, approve alternative selection and cost range, approve performance baseline, approve start of construction, and approve start of operations or project closeout. Assessment of the Results of External Independent Reviews for U. S. Department of Energy Projects summarizes the results.

Linac Coherent Light Source (LCLS) Bunch-Length Monitor Using Coherent Radiation

Download Linac Coherent Light Source (LCLS) Bunch-Length Monitor Using Coherent Radiation PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 3 pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Linac Coherent Light Source (LCLS) Bunch-Length Monitor Using Coherent Radiation by :

Download or read book Linac Coherent Light Source (LCLS) Bunch-Length Monitor Using Coherent Radiation written by and published by . This book was released on 2007 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. One of the most critical diagnostic devices is the bunch length monitor (BLM), which is to be installed right after each compressor utilizing coherent radiation from the last bending magnet. We describe the components and the optical layout of such a BLM. Based on the setup geometry, we discuss some issues about the coherent radiation signal.

The Linac Coherent Light Source at SLAC. Radiological Considerations and Shielding Calculations

Download The Linac Coherent Light Source at SLAC. Radiological Considerations and Shielding Calculations PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 4 pages
Book Rating : 4.:/5 (316 download)

DOWNLOAD NOW!


Book Synopsis The Linac Coherent Light Source at SLAC. Radiological Considerations and Shielding Calculations by : A. Fasso

Download or read book The Linac Coherent Light Source at SLAC. Radiological Considerations and Shielding Calculations written by A. Fasso and published by . This book was released on 2005 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Linac Coherent Light Source (LCLS) at SLAC will be the world's first X-ray free electron laser when it becomes operational in 2009. Pulses of X-ray laser light from LCLS will be many orders of magnitude brighter and several orders of magnitude shorter than what can be produced by other X-ray sources available in the world. These characteristics will enable frontier new science in many areas. This paper describes the LCLS beam parameters and its lay-out. Results of the Monte Carlo calculations for the shielding design of the electron dump line, radiation damage to undulator, the residual radiation and the soil activation around the electron dump are presented.

An Optimized Low-Charge Configuration of the LINAC Coherent Light Source

Download An Optimized Low-Charge Configuration of the LINAC Coherent Light Source PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 3 pages
Book Rating : 4.:/5 (316 download)

DOWNLOAD NOW!


Book Synopsis An Optimized Low-Charge Configuration of the LINAC Coherent Light Source by : J. Wu

Download or read book An Optimized Low-Charge Configuration of the LINAC Coherent Light Source written by J. Wu and published by . This book was released on 2005 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt:

The LINAC Coherent Light Source and Radiological Issues During the Commissioning

Download The LINAC Coherent Light Source and Radiological Issues During the Commissioning PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis The LINAC Coherent Light Source and Radiological Issues During the Commissioning by :

Download or read book The LINAC Coherent Light Source and Radiological Issues During the Commissioning written by and published by . This book was released on 2010 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The Linac Coherent Light Source (LCLS) at SLAC National Accelerator Laboratory is the world's first X-ray free electron laser (XFEL). Pulses of x-ray laser light from LCLS will be many orders of magnitude brighter and several orders of magnitude shorter than what can be produced by other x-ray sources available in the world. These characteristics will enable frontier new science in many areas. This paper describes the LCLS beam parameters and lay-out. The general radiological issues during commissioning are presented, such as radiation dose rates and integrated doses outside the enclosure. Also, specific radiological issues related to X-ray free electron lasers are discussed. XFEL with high peak power will burn through high-Z materials. The X-ray beam needs to be blocked by stoppers when the downstream areas are occupied. LCLS stoppers feature a piece of boron carbide (B4C), 10 mm thick. B4C is one of the best materials since it has a low absorption coefficient for X-rays and a high melting temperature. Theoretical calculations indicate that the unfocused fluence of the LCLS XFEL beam should be about one order of magnitude below the damage threshold for bulk B4C, for 830 eV FEL radiation. However, these calculations have not been tested experimentally and cannot be validated until LCLS begins providing 830 eV XFEL pulses. This paper describes the test plan for using the initial LCLS radiation to evaluate the survivability of B4C and reports the preliminary results. Another major issue for LCLS is the potential radiation damage to the LCLS undulator magnets during operation. TLD dosimeters were installed along the LCLS undulators for each period of two or three weeks. This paper reports the integrated doses along the undulators with and without XFEL generation.

An Overview of Near-Field Vs. Far-Field Radiation Characteristics of the Linac Coherent Light Source (LCLS).

Download An Overview of Near-Field Vs. Far-Field Radiation Characteristics of the Linac Coherent Light Source (LCLS). PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis An Overview of Near-Field Vs. Far-Field Radiation Characteristics of the Linac Coherent Light Source (LCLS). by :

Download or read book An Overview of Near-Field Vs. Far-Field Radiation Characteristics of the Linac Coherent Light Source (LCLS). written by and published by . This book was released on 2005 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The unusually long insertion devices being prepared for Angstrom-wavelength Free Electron Lasers (FELs) will generate spectral-angular distributions in the proposed experimental areas that are substantially different from those conventionally calculated for the far field. In this paper we provide a general overview of near-field effects and report on initial computational simulations of near vs. far field distributions for the SLAC linac Coherent Light Source (LCLS) undulator, an insertion device approximately 140 meters long. The properties of the coherent radiation as a limiting case of the near-field emission, for the special condition of a microbunched beam radiating along the undulator axis, are reviewed.