Seventh Personnel Dosimetry Intercomparison Study

Download Seventh Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (962 download)

DOWNLOAD NOW!


Book Synopsis Seventh Personnel Dosimetry Intercomparison Study by :

Download or read book Seventh Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1981 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The Seventh Personnel Dosimetry Intercomparison Study was conducted March 31-April 10, 1981, at the Oak Ridge National Laboratory. Dosimeters from 34 participating agencies were mounted on anthropomorphic phantoms and exposed to a range of low-level dose equivalents (1.5-15.0mSv neutron and 0.1-2.8 mSv gamma) which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor, operating in the steady-state mode, served as the source of radiation for two equivalent sets of six separate exposures. Lucite and concrete shields along with the unshielded reactor provided three different neutron and gamma spectra for five of the exposures in each set. Results reported by the participating agencies showed that no single type of neutron dosimeter exhibited acceptable performance characteristics for all mixed-field environments encountered in this study. Film, TLD, and TLD-albed dosimeters were found to be inadequate for neutron dose equivalent measurements when large numbers of slow neutrons are present unless significant corrections are made to measured results. Track dosimeters indicated the least sensitivity to spectral characteristics, but did not always yield to the most accurate results. Gamma dose measurements showed that TLD-700 dosimeters produced significantly more accurate results than film dosimeters which tend to overestimate gamma doses in mixed radiation fields.

Personnel Dosimetry Intercomparison Study

Download Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (13 download)

DOWNLOAD NOW!


Book Synopsis Personnel Dosimetry Intercomparison Study by : Oak Ridge National Laboratory

Download or read book Personnel Dosimetry Intercomparison Study written by Oak Ridge National Laboratory and published by . This book was released on 1979 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Sixth Personnel Dosimetry Intercomparison Study

Download Sixth Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (96 download)

DOWNLOAD NOW!


Book Synopsis Sixth Personnel Dosimetry Intercomparison Study by :

Download or read book Sixth Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1981 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The Sixth Personnel Dosimetry Intercomparison Study was conducted March 25 to 27, 1980, at the Oak Ridge National Laboratory. Dosimeters from 28 participating agencies were mounted on anthropomorphic phantoms and exposed to a range of low-level dose equivalents (1.8 to 11.5 mSv neutron, 0.1 to 1.1 mSv gamma) which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor (HPRR) operated in the steady-state mode served as the source of radiation for six separate exposures. Lucite and concrete shields along with the unshielded reactor were used to provide three different neutron and gamma spectra. Results reported by the participating agencies showed that TLD-albedo and TLD-700 dosimeters generally provided the most accurate measurements of neutron and gamma dose equivalents, respectively. Film was found to be unsatisfactory for measuring neutron doses produced by HPRR spectra in that measured dose equivalents were much lower than reference values. The TLD-100 dosimeters yielded gamma doses which were much too high indicating that this dosimeter type is generally unsuitable for use in mixed radiation fields similar to those encountered in this study without the use of large correction factors. Although the overall reported results exhibited improvement in performance relative to previous intercomparison studies, the composite measured data showed variations of more than a factor of 2 between measurements of the same exposure made by different agencies.

Fifth personnel dosimetry intercomparison study

Download Fifth personnel dosimetry intercomparison study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 69 pages
Book Rating : 4.:/5 (658 download)

DOWNLOAD NOW!


Book Synopsis Fifth personnel dosimetry intercomparison study by : C. S. Sims

Download or read book Fifth personnel dosimetry intercomparison study written by C. S. Sims and published by . This book was released on 1980 with total page 69 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Third Personnel Dosimetry Intercomparison Study

Download Third Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 20 pages
Book Rating : 4.:/5 (624 download)

DOWNLOAD NOW!


Book Synopsis Third Personnel Dosimetry Intercomparison Study by : L. W. Gilley

Download or read book Third Personnel Dosimetry Intercomparison Study written by L. W. Gilley and published by . This book was released on 1979 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Fourth Personnel Dosimetry Intercomparison Study

Download Fourth Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 36 pages
Book Rating : 4.:/5 (674 download)

DOWNLOAD NOW!


Book Synopsis Fourth Personnel Dosimetry Intercomparison Study by : H. W. Dickson

Download or read book Fourth Personnel Dosimetry Intercomparison Study written by H. W. Dickson and published by . This book was released on 1980 with total page 36 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Fifth Personnel Dosimetry Intercomparison Study

Download Fifth Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Fifth Personnel Dosimetry Intercomparison Study by :

Download or read book Fifth Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1980 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The fifth Personnel Dosimetry Intercomparison Study (PDIS) was conducted at the Oak Ridge National Laboratory's (ORNL) Dosimetry Applications Research (DOSAR) facility on March 20-22, 1979. This study is the latest PDIS in the continuing series started at the DOSAR facility in 1974. The PDIS is a three day study, typically in March, where personnel dosimeters are mailed to the DOSAR facility, exposed to a range of low-level neutron radiation doses (1 to 15 mSv or equivalently, 100 to 1500 mrem) and neutron-to-gamma ratios (1:1-10:1) using the Health Physics Research Reactor (HPRR) as the radiation source, and returned to the participants for evaluation. This report is a summary and analysis of the results reported by the various participants. The participants are able to intercompare their results with those of others who made dose measurements under identical experimental conditions.

Tenth ORNL Personnel Dosimetry Intercomparison Study

Download Tenth ORNL Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (758 download)

DOWNLOAD NOW!


Book Synopsis Tenth ORNL Personnel Dosimetry Intercomparison Study by : R. E. Swaja

Download or read book Tenth ORNL Personnel Dosimetry Intercomparison Study written by R. E. Swaja and published by . This book was released on 1985 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Fourth Personnel Dosimetry Intercomparison Study

Download Fourth Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Fourth Personnel Dosimetry Intercomparison Study by :

Download or read book Fourth Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1980 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The fourth Personnel Dosimetry Intercomparison Study was held at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during March 15-23, 1978. The Health Physics Research Reactor (HPRR) used unshielded, with a 12-cm-thick Lucite shield, a 20-cm-thick concrete shield, or a 5-cm-thick steel and 15-cm-thick concrete shield, and provided four neutron and gamma-ray spectra. Then the dose was calculated based on the HPRR neutron spectra and dose conversion factors which had been determined previously for the four spectra. The results of these personnel dosimetry intercomparison studies reveal that estimates of dose equivalent vary over a wide range. The standard deviation of the mean of participants data for gamma measurements was in the range of 29 to 43%; for neutrons it was 57 to 188%. (PCS).

Personnel Dosimetry Intercomparison Studies at the ORNL Health Physics Research Reactor

Download Personnel Dosimetry Intercomparison Studies at the ORNL Health Physics Research Reactor PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Personnel Dosimetry Intercomparison Studies at the ORNL Health Physics Research Reactor by :

Download or read book Personnel Dosimetry Intercomparison Studies at the ORNL Health Physics Research Reactor written by and published by . This book was released on 1977 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The Health Physics Research Reactor (HPRR), used unshielded, with a 12-cm-thick Lucite shield or a 13-cm-thick steel shield, provided three neutron and gamma-ray spectra for personnel dosimetry intercomparison studies. The characterisitcs of these fields, such as neutron energy spectrum, intensity, and uniformity, had been measured previously during nuclear accident dosimetry studies. Exposures were made to simulate total exposures likely to be encountered in personnel dosimetry. Neutron dose equivalents of the order of 500 mrem were produced. Dosimeters were mounted on the trunk section of water-filled phantoms, the front edges of which were located three meters from the reactor center. When shields were used they were placed at two meters. Sulfur pellets exposed at a standard location on the reactor during the intercomparison were used to calculate values of tissue kerma for neutrons at the three meter position based on previous measurements. Hurst proportional counter measurements made at the time of the exposures are in good agreement with these results. The gamma component of dose, typically of the order of a few tens of mrad, was measured with LiF thermoluminescent dosimeters (TLD's). Using the fission yield and the calculated leakage of the HPRR, the neutron fluence was calculated for each reactor run. Then the dose was calculated based on the HPRR neutron spectra and the dose conversion factors which had been calculated previously for the three spectra. The results of these personnel dosimetry intercomparison studies reveal that estimates of dose equivalent vary over a wide range. The standard deviation of the mean of participants data was typically in the range of +-30 to +-40%. It is anticipated that this type of dosimetry intercomparison study will be worthwhile on an annual basis until the problems in dosimeter response and interpretation have been identified and solved.

Third Personnel Dosimetry Intercomparison Study

Download Third Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Third Personnel Dosimetry Intercomparison Study by :

Download or read book Third Personnel Dosimetry Intercomparison Study written by and published by . This book was released on 1979 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The third Personnel Dosimetery Intercomparison Study was held at the Oak Ridge National Laboratory Dosimetry Applications Research Facility during March 15--16, 1977. The Health Physics Research Reactor (HPRR), used unshielded, with a 12-cm-thick Lucite shield or a 13-cm-thick steel shield, provided three neutron and gamma-ray spectra. The characteristics of these fields such as neutron energy spectra, intensity, and uniformity had been measured previously during nuclear accident dosimetry studies. Exposures were made to simulate total exposures likely to be encountered in personnel dosimetry. Neutron dose equivalents of the order of 500 millirem were produced by controlling the reactor power level and exposure time. Dosimeters were mounted on the trunk section of water-filled phantoms, the front edges of which were located 3 m from the reactor center. When shields were used they were placed at 2 m from the core. Sulfur pellets exposed at a standard location on the reactor during the intercomparison were used to calculate values of tissue kerma for neutrons at the 3-m position based on previous measurements. Using the fission yield and the calculated leakage of the HPRR, the neutron fluence was calculated for each reactor run. Then the dose was calculated based on the HPRR neutron spectra and the dose conversion factors, which had been calculated previously for the three spectra. The results of these personnel dosimetry intercomparison studies reveal that estimates of dose equivalent vary over a wide range. The standard deviation of the mean of participants data was in the range of 25 to 50%.

Eleventh ORNL Personnel Dosimetry Intercomparison Study

Download Eleventh ORNL Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (758 download)

DOWNLOAD NOW!


Book Synopsis Eleventh ORNL Personnel Dosimetry Intercomparison Study by : R. E. Swaja

Download or read book Eleventh ORNL Personnel Dosimetry Intercomparison Study written by R. E. Swaja and published by . This book was released on 1986 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Tenth Dosimetry Intercomparison Study, August 27--September 7, 1973

Download Tenth Dosimetry Intercomparison Study, August 27--September 7, 1973 PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (957 download)

DOWNLOAD NOW!


Book Synopsis Tenth Dosimetry Intercomparison Study, August 27--September 7, 1973 by :

Download or read book Tenth Dosimetry Intercomparison Study, August 27--September 7, 1973 written by and published by . This book was released on 1975 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Twelve Years of Neutron Personnel Dosimetry Intercomparison Studies at Oak Ridge National Laboratory

Download Twelve Years of Neutron Personnel Dosimetry Intercomparison Studies at Oak Ridge National Laboratory PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Twelve Years of Neutron Personnel Dosimetry Intercomparison Studies at Oak Ridge National Laboratory by :

Download or read book Twelve Years of Neutron Personnel Dosimetry Intercomparison Studies at Oak Ridge National Laboratory written by and published by . This book was released on 1988 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: To provide an opportunity for dosimetrists to test and calibrate their personnel neutron monitoring systems in a variety of incident radiation fields, the staff of the Dosimetry Applications Research (DOSAR) Facility at the Oak Ridge National Laboratory (ORNL) has conducted personnel dosimetry intercomparison studies (PDIS) periodically since 1974 and annually since 1976 (Si82, Sw87). During these studies, personnel dosimeters are mailed to ORNL, mounted on phantoms and exposed to low-level (less than 15 mSv) dose equivalents in mixed-radiation fields mainly produced using the Health Physics Research Reactor (HPRR) at ORNL (Au65), and then returned to the participants for evaluation. Reported dose equivalents are compared to reference values provided by the DOSAR staff and to results reported by individual organizations which made measurements under identical conditions. These intercomparisons, which require no fee and are open to any organization interested in external personnel dosimetry, have provided more data concerning neutron dosimeter performance characteristics in mixed-radiation fields than any other periodic open test program conducted to date. The following text presents a summary and analysis of neutron dose equivalent measurements reported for the seventh through twelfth intercomparisons (1981-1986) using the HPRR as the source of radiation. Particular factors examined include low dose equivalent sensitivity and measurement accuracy for the basic types of neutron personnel dosimeters. 5 refs., 1 fig.

Energy Research Abstracts

Download Energy Research Abstracts PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 526 pages
Book Rating : 4.0/5 ( download)

DOWNLOAD NOW!


Book Synopsis Energy Research Abstracts by :

Download or read book Energy Research Abstracts written by and published by . This book was released on 1993-12 with total page 526 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Summary and Analysis of the 1986 ORNL Personnel Dosimetry Intercomparison Study

Download Summary and Analysis of the 1986 ORNL Personnel Dosimetry Intercomparison Study PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (758 download)

DOWNLOAD NOW!


Book Synopsis Summary and Analysis of the 1986 ORNL Personnel Dosimetry Intercomparison Study by : R. E. Swaja

Download or read book Summary and Analysis of the 1986 ORNL Personnel Dosimetry Intercomparison Study written by R. E. Swaja and published by . This book was released on 1987 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Summary and Analysis of Neutron Measurements Conducted During the Oak Ridge Personnel Dosimetry Intercomparison Studies

Download Summary and Analysis of Neutron Measurements Conducted During the Oak Ridge Personnel Dosimetry Intercomparison Studies PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Summary and Analysis of Neutron Measurements Conducted During the Oak Ridge Personnel Dosimetry Intercomparison Studies by :

Download or read book Summary and Analysis of Neutron Measurements Conducted During the Oak Ridge Personnel Dosimetry Intercomparison Studies written by and published by . This book was released on 1987 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Since 1974, neutron personnel dosimetry intercomparison studies (PDIS) have been conducted annually at the Oak Ridge National Laboratory's (ORNL) Dosimetry Applications Research Facility. During these studies, neutron dosimeters are mailed to ORNL, exposed to low-level (less than 15 mSv) dose equivalents in a variety of mixed-radiation fields produced using the Health Physics Research Reactor (HPRR), and then returned to the participants for evaluation. Beginning with the Seventh PDIS in 1981, interest and participation in the Oak Ridge intercomparisons increased significantly and consistent and documented techniques for determining reference neutron dose equivalents for the HPRR were introduced. This document presents a summary and analysis of approximately 3400 neutron dose equivalent measurements made using a variety of personnel dosimeters and reported for PDIS 7-12. 16 refs., 3 tabs.