Neutron Personnel Dosimetry

Download Neutron Personnel Dosimetry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 52 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Neutron Personnel Dosimetry by : Robert B. Schwartz

Download or read book Neutron Personnel Dosimetry written by Robert B. Schwartz and published by . This book was released on 1987 with total page 52 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Neutron Dosimetry in Radiation Protection

Download Neutron Dosimetry in Radiation Protection PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 368 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Neutron Dosimetry in Radiation Protection by : H. Ing

Download or read book Neutron Dosimetry in Radiation Protection written by H. Ing and published by . This book was released on 1985 with total page 368 pages. Available in PDF, EPUB and Kindle. Book excerpt:

American National Standard-- Personnel Neutron Dosimeters (neutron Energies Less Than 20 MeV).

Download American National Standard-- Personnel Neutron Dosimeters (neutron Energies Less Than 20 MeV). PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 26 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis American National Standard-- Personnel Neutron Dosimeters (neutron Energies Less Than 20 MeV). by :

Download or read book American National Standard-- Personnel Neutron Dosimeters (neutron Energies Less Than 20 MeV). written by and published by . This book was released on 2000 with total page 26 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Techniques and Management of Personnel Thermoluminescence Dosimetry Services

Download Techniques and Management of Personnel Thermoluminescence Dosimetry Services PDF Online Free

Author :
Publisher : Springer Science & Business Media
ISBN 13 : 9780792324362
Total Pages : 462 pages
Book Rating : 4.3/5 (243 download)

DOWNLOAD NOW!


Book Synopsis Techniques and Management of Personnel Thermoluminescence Dosimetry Services by : M. Oberhofer

Download or read book Techniques and Management of Personnel Thermoluminescence Dosimetry Services written by M. Oberhofer and published by Springer Science & Business Media. This book was released on 1993-10-31 with total page 462 pages. Available in PDF, EPUB and Kindle. Book excerpt: The International Commission on Radiological Protection and the Euratom Council directive have specified that workers exposed to ionizing radiation shall be subjected to individual dose monitoring. In the past, individual doses have almost always been monitored by film badge dosimeters, but thermoluminescent dosimeters (TLDs) are now coming into widespread use, principally due to the availability of automated readout systems. Techniques and Management of Personnel Thermoluminescence Dosimetry Services gives details of the operation of and experience gained with a number of large-scale TL personnel dosimetry services, with particular attention being paid to the management aspects of such services. For technical and administrative personnel in TLD services, TLD system designers, staff of licensing authorities concerned with dosimetric licensing, students of radiation protection, especially in the area of protection from ionizing radiation. A basic knowledge of atomic and nuclear physics is assumed, and a training in radiation protection or health physics would be an advantage.

Personnel Neutron Dose Assessment Upgrade

Download Personnel Neutron Dose Assessment Upgrade PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Personnel Neutron Dose Assessment Upgrade by :

Download or read book Personnel Neutron Dose Assessment Upgrade written by and published by . This book was released on 1988 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This report provides guidance on the characteristics, use, and calibration criteria for personnel neutron dosimeters. The report is applicable for neutrons with energies ranging from thermal to less than 20 MeV. Background for general neutron dosimetry requirements is provided, as is relevant federal regulations and other standards. The characteristics of personnel neutron dosimeters are discussed, with particular attention paid to passive neutron dosimetry systems. Two of the systems discussed are used at DOE and DOE-contractor facilities (nuclear track emulsion and thermoluminescent-albedo) and another (the combination TLD/TED) was recently developed. Topics discussed in the field applications of these dosimeters include their theory of operation, their processing, readout, and interpretation, and their advantages and disadvantages for field use. The procedures required for occupational neutron dosimetry are discussed, including radiation monitoring and the wearing of dosimeters, their exchange periods, dose equivalent evaluations, and the documenting of neutron exposures. The coverage of dosimeter testing, maintenance, and calibration includes guidance on the selection of calibration sources, the effects of irradiation geometries, lower limits of detectability, fading, frequency of calibration, spectrometry, and quality control. 49 refs., 6 figs., 8 tabs.

Intercomparison of High Energy Neutron Personnel Dosimeters

Download Intercomparison of High Energy Neutron Personnel Dosimeters PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 7 pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis Intercomparison of High Energy Neutron Personnel Dosimeters by :

Download or read book Intercomparison of High Energy Neutron Personnel Dosimeters written by and published by . This book was released on 1993 with total page 7 pages. Available in PDF, EPUB and Kindle. Book excerpt: An intercomparison of high-energy neutron personnel dosimeters was performed to evaluate the uniformity of the response characteristics of typical neutron dosimeters presently in use at US Department of Energy (DOE) accelerator facilities. It was necessary to perform an intercomparison because there are no national or international standards for high-energy neutron dosimetry. The testing that is presently under way for the Department of Energy Laboratory Accreditation Program (DOELAP) is limited to the use of neutron sources that range in energy from about 1 keV to 2 MeV. Therefore, the high-energy neutron dosimeters presently in use at DOE accelerator facilities are not being tested effectively. This intercomparison employed neutrons produced by the 9Be(p, n)9B interaction at the University of Washington cyclotron, using 50-MeV protons. The resulting neutron energy spectrum extended to a maximum of approximately 50-MeV, with a mean energy of about 20-MeV. Intercomparison results for currently used dosimeters, including Nuclear Type A (NTA) film, thermoluminescent dosimeter (TLD)-albedo, and track-etch dosimeters (TEDs), indicated a wide variation in response to identical doses of high-energy neutrons. Results of this study will be discussed along with a description of plans for future work.

Neutron Dosimetry

Download Neutron Dosimetry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 116 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Neutron Dosimetry by : John W. Baum

Download or read book Neutron Dosimetry written by John W. Baum and published by . This book was released on 1955 with total page 116 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Twelve Years of Neutron Personnel Dosimetry Intercomparison Studies at Oak Ridge National Laboratory

Download Twelve Years of Neutron Personnel Dosimetry Intercomparison Studies at Oak Ridge National Laboratory PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Twelve Years of Neutron Personnel Dosimetry Intercomparison Studies at Oak Ridge National Laboratory by :

Download or read book Twelve Years of Neutron Personnel Dosimetry Intercomparison Studies at Oak Ridge National Laboratory written by and published by . This book was released on 1988 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: To provide an opportunity for dosimetrists to test and calibrate their personnel neutron monitoring systems in a variety of incident radiation fields, the staff of the Dosimetry Applications Research (DOSAR) Facility at the Oak Ridge National Laboratory (ORNL) has conducted personnel dosimetry intercomparison studies (PDIS) periodically since 1974 and annually since 1976 (Si82, Sw87). During these studies, personnel dosimeters are mailed to ORNL, mounted on phantoms and exposed to low-level (less than 15 mSv) dose equivalents in mixed-radiation fields mainly produced using the Health Physics Research Reactor (HPRR) at ORNL (Au65), and then returned to the participants for evaluation. Reported dose equivalents are compared to reference values provided by the DOSAR staff and to results reported by individual organizations which made measurements under identical conditions. These intercomparisons, which require no fee and are open to any organization interested in external personnel dosimetry, have provided more data concerning neutron dosimeter performance characteristics in mixed-radiation fields than any other periodic open test program conducted to date. The following text presents a summary and analysis of neutron dose equivalent measurements reported for the seventh through twelfth intercomparisons (1981-1986) using the HPRR as the source of radiation. Particular factors examined include low dose equivalent sensitivity and measurement accuracy for the basic types of neutron personnel dosimeters. 5 refs., 1 fig.

The Present Status of Neutron Monitoring for Personnel Protection

Download The Present Status of Neutron Monitoring for Personnel Protection PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 29 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis The Present Status of Neutron Monitoring for Personnel Protection by :

Download or read book The Present Status of Neutron Monitoring for Personnel Protection written by and published by . This book was released on 1966 with total page 29 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Neutron Personnel Dosimetry Considerations for Fusion Reactors

Download Neutron Personnel Dosimetry Considerations for Fusion Reactors PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (96 download)

DOWNLOAD NOW!


Book Synopsis Neutron Personnel Dosimetry Considerations for Fusion Reactors by :

Download or read book Neutron Personnel Dosimetry Considerations for Fusion Reactors written by and published by . This book was released on 1979 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The increasing development of fusion reactor technology warrants an evaluation of personnel neutron dosimetry systems to aid in the concurrent development of a radiation protection program. For this reason, current state of knowledge neutron dosimeters have been reviewed with emphasis placed on practical utilization and the problems inherent in each type of dosimetry system. Evaluations of salient parameters such as energy response, latent image instability, and minimum detectable dose equivalent are presented for nuclear emulsion films, track etch techniques, albedo and other thermoluminescent dosimetry techniques, electrical conductivity damage effects, lyoluminescence, thermocurrent, and thermally stimulated exoelectron emission. Brief summaries of dosimetry regulatory requirements and intercomparison study results help to establish compliance and recent trends, respectively. Spectrum modeling data generated by the Neutron Physics Division of Oak Ridge National Laboratory for the Princeton Tokamak Fusion Test Reactor (TFTR) Facility have been analyzed by both International Commission on Radiological Protection fluence to dose conversion factors and an adjoint technique of radiation dosimetry, in an attempt to determine the applicability of current neutron dosimetry systems to deuterium and tritium fusion reactor leakage spectra. Based on the modeling data, a wide range of neutron energies will probably be present in the leakage spectra of the TFTR facility, and no appreciable risk of somatic injury to occupationally exposed workers is expected. The relative dose contributions due to high energy and thermal neutrons indicate that neutron dosimetry will probably not be a serious limitation in the development of fusion power.

Neutron Monitoring for Radiation Protection Purposes

Download Neutron Monitoring for Radiation Protection Purposes PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 536 pages
Book Rating : 4.F/5 ( download)

DOWNLOAD NOW!


Book Synopsis Neutron Monitoring for Radiation Protection Purposes by :

Download or read book Neutron Monitoring for Radiation Protection Purposes written by and published by . This book was released on 1973 with total page 536 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Second AEC Workshop on Personnel Neutron Dosimetry

Download Second AEC Workshop on Personnel Neutron Dosimetry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 116 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Second AEC Workshop on Personnel Neutron Dosimetry by :

Download or read book Second AEC Workshop on Personnel Neutron Dosimetry written by and published by . This book was released on 1971 with total page 116 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Personnel Neutron Dosimetry Studies at the Lawrence Livermore National Laboratory

Download Personnel Neutron Dosimetry Studies at the Lawrence Livermore National Laboratory PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Personnel Neutron Dosimetry Studies at the Lawrence Livermore National Laboratory by :

Download or read book Personnel Neutron Dosimetry Studies at the Lawrence Livermore National Laboratory written by and published by . This book was released on 1981 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: A study was conducted to determine the effect of phantom size, shape and composition on the response of an albedo neutron dosimeter. The most important feature was the shape. The dose equivalent rate from a californium neutron source was determined. Ten different dose rates were determined which varied from 2.39 to 3.02 rem/h for the CF source used. (ACR).

Personnel Neutron Dosimetry at Department of Energy Facilities

Download Personnel Neutron Dosimetry at Department of Energy Facilities PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Personnel Neutron Dosimetry at Department of Energy Facilities by :

Download or read book Personnel Neutron Dosimetry at Department of Energy Facilities written by and published by . This book was released on 1980 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This study assesses the state of personnel neutron dosimetry at DOE facilities. A survey of the personnel dosimetry systems in use at major DOE facilities was conducted, a literature search was made to determine recent advances in neutron dosimetry, and several dosimetry experts were interviewed. It was concluded that personnel neutron dosimeters do not meet current needs and that serious problems exist now and will increase in the future if neutron quality factors are increased and/or dose limits are lowered.

Solid State Dosimetry

Download Solid State Dosimetry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 352 pages
Book Rating : 4.:/5 (45 download)

DOWNLOAD NOW!


Book Synopsis Solid State Dosimetry by : Klaus Becker

Download or read book Solid State Dosimetry written by Klaus Becker and published by . This book was released on 1973 with total page 352 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Personnel Neutron Dosimetry Area Monitoring Using Solid-State Track Recorders

Download Personnel Neutron Dosimetry Area Monitoring Using Solid-State Track Recorders PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 8 pages
Book Rating : 4.:/5 (125 download)

DOWNLOAD NOW!


Book Synopsis Personnel Neutron Dosimetry Area Monitoring Using Solid-State Track Recorders by : FH. Ruddy

Download or read book Personnel Neutron Dosimetry Area Monitoring Using Solid-State Track Recorders written by FH. Ruddy and published by . This book was released on 1989 with total page 8 pages. Available in PDF, EPUB and Kindle. Book excerpt: Personnel neutron dosimeters using a number of different techniques have been developed for routine use in neutron fields, but all of these dosimeters must be carefully corrected to account for the fact that their response is critically dependent upon the energy distribution of the neutron field. At present, personnel neutron dosimeters are typically calibrated in a standard neutron field (e.g., 252Cf or D2O-moderated 252Cf)- but may then be applied in neutron fields that vary considerably from the calibration field. Some widely used personnel dosimeters, such as TLD-albedo dosimeters, overrespond to low energy neutrons and therefore deliver high readings in fields that are more moderated than the standard field.

Retrospective Assessment of Personnel Neutron Dosimetry for Workers at the Hanford Site

Download Retrospective Assessment of Personnel Neutron Dosimetry for Workers at the Hanford Site PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Retrospective Assessment of Personnel Neutron Dosimetry for Workers at the Hanford Site by :

Download or read book Retrospective Assessment of Personnel Neutron Dosimetry for Workers at the Hanford Site written by and published by . This book was released on 2001 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This report was prepared to examine the specific issue of the potential for unrecorded neutron dose for Hanford workers, particularly in comparison with the recorded whole body (neutron plus photon) dose. During the past several years, historical personnel dosimetry practices at Hanford have been documented in several technical reports. This documentation provides a detailed history of the technology, radiation fields, and administrative practices used to measure and record dose for Hanford workers. Importantly, documentation has been prepared by personnel whose collective experience spans nearly the entire history of Hanford operations beginning in the mid-1940s. Evaluations of selected Hanford radiation dose records have been conducted along with statistical profiles of the recorded dose data. The history of Hanford personnel dosimetry is complex, spanning substantial evolution in radiation protection technology, concepts, and standards. Epidemiologic assessments of Hanford worker mortality and radiation dose data were initiated in the early 1960s. In recent years, Hanford data have been included in combined analyses of worker cohorts from several Department of Energy (DOE) sites and from several countries through the International Agency for Research on Cancer (IARC). Hanford data have also been included in the DOE Comprehensive Epidemiologic Data Resource (CEDR). In the analysis of Hanford, and other site data, the question of comparability of recorded dose through time and across the respective sites has arisen. DOE formed a dosimetry working group composed of dosimetrists and epidemiologists to evaluate data and documentation requirements of CEDR. This working group included in its recommendations the high priority for documentation of site-specific radiation dosimetry practices used to measure and record worker dose by the respective DOE sites.