National Dam Safety Program. Platte River Tributaries Dam 3-B (MO 11054), Missouri - Nemaha - Nodaway Basin, Worth County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Platte River Tributaries Dam 3-B (MO 11054), Missouri - Nemaha - Nodaway Basin, Worth County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 101 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Platte River Tributaries Dam 3-B (MO 11054), Missouri - Nemaha - Nodaway Basin, Worth County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. Platte River Tributaries Dam 3-B (MO 11054), Missouri - Nemaha - Nodaway Basin, Worth County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1980 with total page 101 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of the inspection was to make an assessment of the general conditions of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. In accordance with the guidelines and based on visual observation, the dam is classified as having a high potential for damage and loss of life. Failure would threaten life and property. The estimated damage zone extends approximately one (1) mile downstream of the dam. The inspection and evaluation indicates that the spillways meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded, one-half of the Probable Maximum Flood is the appropriate spillway design flood. The spillways will pass the 100-year flood (1% probability flood - a flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillways will pass 65% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

Technical Abstract Bulletin

Download Technical Abstract Bulletin PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 206 pages
Book Rating : 4.E/5 ( download)

DOWNLOAD NOW!


Book Synopsis Technical Abstract Bulletin by :

Download or read book Technical Abstract Bulletin written by and published by . This book was released on 1981 with total page 206 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Government Reports Announcements & Index

Download Government Reports Announcements & Index PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 1620 pages
Book Rating : 4.E/5 ( download)

DOWNLOAD NOW!


Book Synopsis Government Reports Announcements & Index by :

Download or read book Government Reports Announcements & Index written by and published by . This book was released on 1982 with total page 1620 pages. Available in PDF, EPUB and Kindle. Book excerpt:

National Dam Safety Program. Oswald Dam (MO 11031), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Oswald Dam (MO 11031), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 58 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Oswald Dam (MO 11031), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. Oswald Dam (MO 11031), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1979 with total page 58 pages. Available in PDF, EPUB and Kindle. Book excerpt: The dam is an earthfill structure approximately 155 feet long and 40 feet in height. It is located in a deeply incised gully in the deep loess hill country adjacent to the Missouri River Valley in northwestern Missouri. The principal spillway consists of a 24-inch diameter steel pipe with a hood inlet which passes through the embankment on an angle of about 30 deg to the centerline of the dam. A vegetated earth emergency spillway is cut through the abutment on the left (north) end of the dam. The bottom width of the spillway is 25 feet. A vegetated earth emergency spillway is cut through the abutment on the right (south) end of the dam. The bottom width of the spillway is 20 feet. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. The spillways will pass 13% of the Probable Maximum Flood without overtopping the dam.

Government Reports Annual Index

Download Government Reports Annual Index PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 1008 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Government Reports Annual Index by :

Download or read book Government Reports Annual Index written by and published by . This book was released on 1982 with total page 1008 pages. Available in PDF, EPUB and Kindle. Book excerpt: Sections 1-2. Keyword Index.--Section 3. Personal author index.--Section 4. Corporate author index.-- Section 5. Contract/grant number index, NTIS order/report number index 1-E.--Section 6. NTIS order/report number index F-Z.

National Dam Safety Program. 102 Rivers, C-5 Dam (MO 10996), Missouri - Nemaha - Nodaway Basin, Nodaway County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. 102 Rivers, C-5 Dam (MO 10996), Missouri - Nemaha - Nodaway Basin, Nodaway County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 96 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. 102 Rivers, C-5 Dam (MO 10996), Missouri - Nemaha - Nodaway Basin, Nodaway County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. 102 Rivers, C-5 Dam (MO 10996), Missouri - Nemaha - Nodaway Basin, Nodaway County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1979 with total page 96 pages. Available in PDF, EPUB and Kindle. Book excerpt: 102 Rivers, C-5 Dam, was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the downstream hazards involved and the amount of water impounded, 50% of the Probable Maximum Flood is the appropriate spillway design flood. The spillway will pass the 100-year flood (flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillway will pass 35% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

Government Reports Annual Index: Keyword A-L

Download Government Reports Annual Index: Keyword A-L PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 1016 pages
Book Rating : 4.:/5 (319 download)

DOWNLOAD NOW!


Book Synopsis Government Reports Annual Index: Keyword A-L by :

Download or read book Government Reports Annual Index: Keyword A-L written by and published by . This book was released on 1982 with total page 1016 pages. Available in PDF, EPUB and Kindle. Book excerpt:

National Dam Safety Program. MO Noname 27 Dam (MO 10353), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. MO Noname 27 Dam (MO 10353), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 54 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. MO Noname 27 Dam (MO 10353), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. MO Noname 27 Dam (MO 10353), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1979 with total page 54 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report presents the results of field inspection and evaluation of the Mononame 27 Dam: It was prepared under the National Program of Inspection of Non-Federal Dams. This dam has been classified as unsafe, non-emergency by the St. Louis District as a result of the application of the following criteria: Spillway will not pass 50 percent of the Probable Maximum Flood. Overtopping could result in dam failure. Dam failure significantly increases the hazard to loss of life downstream. (Author).

National Dam Safety Program. Frank Milne Dam (MO 11029), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Frank Milne Dam (MO 11029), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 72 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Frank Milne Dam (MO 11029), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. Frank Milne Dam (MO 11029), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1979 with total page 72 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report was prepared under the National Program of Inspection of Non-Federal Dams. This report assesses the general condition of the dam with respect to safety, based on available data and on visual inspection, to determine if the dam poses hazards to human life or property. (Author).

National Dam Safety Program. Ussary Dam (MO 10698), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Ussary Dam (MO 10698), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 74 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Ussary Dam (MO 10698), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. Ussary Dam (MO 10698), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1980 with total page 74 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of the inspection was to make an assessment of the general conditions of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. In accordance with the guidelines and based on visual observation, the dam is classified as having a high potential for damage and loss of life. Failure would threaten life and property. The inspection and evaluation indicates that the spillways do not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded and the downstream channel from the dam, one half of the Probable Maximum Flood is the appropriate spillway design flood. The spillways will not pass the 100-year flood (1% probability flood - a flood having a one percent chance of being exceeded in any one year) without overtopping the dam. The spillways will pass 13% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorological and hydrologic conditions that are reasonably possible in the region.

National Dam Safety Program. Welton Ideker Dam (MO 11010), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Welton Ideker Dam (MO 11010), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 74 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Welton Ideker Dam (MO 11010), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. Welton Ideker Dam (MO 11010), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1979 with total page 74 pages. Available in PDF, EPUB and Kindle. Book excerpt: Welton Ideker Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded, the nature of the downstream channel and the hazards involved, one-half of the Probable Maximum Flood is the appropriate spillway design flood. The spillway will not pass the 100-year flood (flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillway will pass 9% of the Probable Maximum Flood as well as the 10-year flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

National Dam Safety Program. Earl Limpp Dam (MO 10508), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Earl Limpp Dam (MO 10508), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 60 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Earl Limpp Dam (MO 10508), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. Earl Limpp Dam (MO 10508), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1979 with total page 60 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. The inspection and evaluation indicates that the spillway does not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded and the large floodplain downstream of the dam, one-half of the Probable Maximum Flood is the appropriate spillway design flood. The spillways will not pass the 100-year flood (flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillways will pass 12% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

National Dam Safety Program. Savannah City Reservoir Dam (MO 10038), Missouri - Nemaha - Nodaway Basin, Andrew County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Savannah City Reservoir Dam (MO 10038), Missouri - Nemaha - Nodaway Basin, Andrew County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 63 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Savannah City Reservoir Dam (MO 10038), Missouri - Nemaha - Nodaway Basin, Andrew County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. Savannah City Reservoir Dam (MO 10038), Missouri - Nemaha - Nodaway Basin, Andrew County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1979 with total page 63 pages. Available in PDF, EPUB and Kindle. Book excerpt: Savannah City Reservoir Dam was inspected to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the volume of water impounded and the large flood plain downstream of the dam, one-half of the Probable Maximum Flood is the appropriate spillway design flood. The spillways will pass the 100-year flood (flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillways will pass 30% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

National Dam Safety Program. McPheeters Lake Dam (MO 10525), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. McPheeters Lake Dam (MO 10525), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 72 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. McPheeters Lake Dam (MO 10525), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. McPheeters Lake Dam (MO 10525), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1980 with total page 72 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report was prepared under the National Program of Inspection of Non-Federal Dams. This report assesses the general condition of the dam with respect to safety, based on available data and on visual inspection, to determine if the dam poses hazards to human life or property. (Author).

National Dam Safety Program. Hall Dam (MO 11038), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Hall Dam (MO 11038), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 81 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Hall Dam (MO 11038), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. Hall Dam (MO 11038), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1980 with total page 81 pages. Available in PDF, EPUB and Kindle. Book excerpt: Hall Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general conditions of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded and the downstream channel from the dam, one half of the Probable Maximum Flood is the appropriate spillway design flood. The spillways will not pass the 100-year flood (1% probability flood, a flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillways will pass 14% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

National Dam Safety Program. Scotty's Lake Dam (MO 10271), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Scotty's Lake Dam (MO 10271), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 52 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Scotty's Lake Dam (MO 10271), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report by : Murray B. Blume

Download or read book National Dam Safety Program. Scotty's Lake Dam (MO 10271), Missouri - Nemaha - Nodaway Basin, Buchanan County, Missouri. Phase I Inspection Report written by Murray B. Blume and published by . This book was released on 1979 with total page 52 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of this inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. The inspection and evaluation indicates the spillway does not meet the criteria set forth in the guidelines for a dam having this size and hazard potential. The emergency spillway will pass neither the probable maximum flood nor 50 percent of the probable maximum flood without overtopping but will pass 10 percent of the probable maximum flood, which is less than the estimated 100-year flood. The dam will pass a 10-year event without being overtopped. The spillway design flood recommended by the guidelines is 50 to 100 percent of the probable maximum flood. The probable maximum flood is defined as the flood discharge that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region. Deficiencies visually observed by the inspection team were erosion and sloughing of the upstream embankment, erosion and sloughing of the downstream embankment, seepage, and the presence of excessive trees on the downstream embankment slope. There were no observed deficiencies or conditions existing at the time of the inspection which indicated an immediate safety hazard. Future corrective action and regular maintenance will be required to correct or control the described deficiencies. In addition, detailed seepage and stability analyses of the existing dam, as required by the guidelines, should be performed.

National Dam Safety Program. Lowell Pierce Dam (MO 11009), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report

Download National Dam Safety Program. Lowell Pierce Dam (MO 11009), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 61 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis National Dam Safety Program. Lowell Pierce Dam (MO 11009), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report by : Rey S. Decker

Download or read book National Dam Safety Program. Lowell Pierce Dam (MO 11009), Missouri - Nemaha - Nodaway Basin, Atchison County, Missouri. Phase I Inspection Report written by Rey S. Decker and published by . This book was released on 1979 with total page 61 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report was prepared under the National Program of Inspection of Non-Federal Dams. This report assesses the general condition of the dam with respect to safety, based on available data and on visual inspection, to determine if the dam poses hazards to human life or property. (Author).