Mise au point d'un diagnostic de fluorescence induite par laser et application à l'étude d'un plasma d'argon multipolaire

Download Mise au point d'un diagnostic de fluorescence induite par laser et application à l'étude d'un plasma d'argon multipolaire PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 352 pages
Book Rating : 4.:/5 (489 download)

DOWNLOAD NOW!


Book Synopsis Mise au point d'un diagnostic de fluorescence induite par laser et application à l'étude d'un plasma d'argon multipolaire by : Laurence Chérigier

Download or read book Mise au point d'un diagnostic de fluorescence induite par laser et application à l'étude d'un plasma d'argon multipolaire written by Laurence Chérigier and published by . This book was released on 1994 with total page 352 pages. Available in PDF, EPUB and Kindle. Book excerpt: NOUS AVONS DEVELOPPE UN DIAGNOSTIC DE FLUORESCENCE INDUITE PAR LASER POUR ETUDIER UN PLASMA D'ARGON CREE PAR UNE DECHARGE THERMOELECTRONIQUE DANS UNE ENCEINTE A CHAMP MAGNETIQUE MULTIPOLAIRE. CE DIAGNOSTIC, BASE SUR L'EFFET DOPPLER, PERMET UNE MESURE PRECISE DE LA FONCTION DE DISTRIBUTION EN VITESSE DES IONS (FDVI) DANS UN PLASMA DE BASSE DENSITE (10#8-10#9 CM##3). UN PROGRAMME INFORMATIQUE PERMET D'AJUSTER LES PARAMETRES D'UN MODELE ANALYTIQUE AUX COURBES EXPERIMENTALES. NOUS AVONS CONSTATE QUE LES FDVI DANS LE CORPS DU PLASMA SONT GAUSSIENNES. POUR UNE PRESSION DE NEUTRES DE 6 10##4 TORR, LA LARGEUR A MI-HAUTEUR NOUS DONNE LA TEMPERATURE IONIQUE DE L'ORDRE DE 0.05 EV, CE QUI EST INFERIEUR A LA TEMPERATURE MESUREE DANS DES CONDITIONS SEMBLABLES PAR DES ANALYSEURS D'ENERGIE. LA VITESSE MOYENNE DES IONS PEUT ETRE RELIEE AU GRADIENT DE POTENTIEL QUI LES ACCELERE VERS LES PAROIS. NOUS AVONS ETUDIE LES CONDITIONS AUX LIMITES DU PLASMA, FORMEES PAR LE CHAMP MAGNETIQUE OU LE VOISINAGE DE LA GAINE ELECTROSTATIQUE DEVANT UNE PLAQUE METALLIQUE. EN EFFECTUANT DES MESURES DANS UNE ARCHE DU CHAMP MAGNETIQUE MULTIPOLAIRE, NOUS MONTRONS SON INFLUENCE SUR LES TRAJECTOIRES DES IONS, SOUMIS A LA FORCE DE LORENTZ. ILS SONT EN PARTICULIER DEVIES ET FORTEMENT ACCELERES DANS LA DIRECTION PARALLELE AUX AIMANTS. LES FONCTIONS DE DISTRIBUTION S'ELARGISSENT DE FACON ANISOTROPE. EN L'ABSENCE DE CHAMP MAGNETIQUE, LES FONCTIONS DE DISTRIBUTION ENREGISTREES PRES D'UNE PLAQUE AU POTENTIEL FLOTTANT OU BIEN A LA MASSE NE SONT PAS GAUSSIENNES: LEUR PROFIL RESSEMBLE A CELUI CALCULE THEORIQUEMENT PAR EMMERT ET AL. NOUS AVONS DONC UTILISE CE MODELE POUR AJUSTER NOS RESULTATS EXPERIMENTAUX. L'ACCORD EST CEPENDANT QUALITATIF, LA TEMPERATURE IONIQUE DANS LE CAS DU MODELE EST FIXEE DES LA CREATION DES IONS ALORS QUE NOUS OBSERVONS EXPERIMENTALEMENT UN ELARGISSEMENT DES DISTRIBUTIONS A L'APPROCHE DE LA PLAQUE

Tracer-based Planar Laser-induced Fluorescence Diagnostics

Download Tracer-based Planar Laser-induced Fluorescence Diagnostics PDF Online Free

Author :
Publisher : Stanford University
ISBN 13 :
Total Pages : 197 pages
Book Rating : 4.F/5 ( download)

DOWNLOAD NOW!


Book Synopsis Tracer-based Planar Laser-induced Fluorescence Diagnostics by : Brian Ho-yin Cheung

Download or read book Tracer-based Planar Laser-induced Fluorescence Diagnostics written by Brian Ho-yin Cheung and published by Stanford University. This book was released on 2011 with total page 197 pages. Available in PDF, EPUB and Kindle. Book excerpt: Two advances to tracer-based planar laser-induced fluorescence (PLIF) diagnostics are presented in this work. The first improvement is the development of a 3-pentanone fluorescence quantum yield (FQY) database and model for a wide range of conditions in support of quantitative PLIF diagnostics. In addition, this work presents a sensitive, time-resolved tracer-based PLIF diagnostic, accomplished by using a continuous-wave (CW) laser with the high-FQY tracer toluene. Because of its ease of use and desirable photophysical properties, PLIF diagnostics using 3-pentanone as a tracer are common, particularly for internal combustion engine (ICE) diagnostics. Thus, there is a need for 3-pentanone FQY measurements and modeling over a wide range of temperatures, pressures, and excitation wavelengths. For insight into the collisionless process in the FQY model, measurements were made in 3-pentanone vapor at low-pressures across a range of temperatures using a flowing cell. Laser excitation with 248, 266, 277, 308 nm wavelengths were utilized, and Rayleigh scattering of the laser beam was used to calibrate the optical efficiency of the collection optics and detector. This low-pressure data allows calculation of the 3-pentanone fluorescence rate and non-radiative de-excitation rate in the fluorescence model. The vibrational relaxation cascade parameter for 3-pentanone collisions was also determined. Measurements of 3-pentanone FQY were also made over a range of temperatures and pressures relevant to diagnostic applications, and, in particular, combined high-temperature and high-pressure conditions applicable to internal combustion engines (ICE). These data were collected in a custom-built optical cell capable of simultaneous high-pressure and high-temperature conditions. The behavior of the FQY in nitrogen for temperatures up to 745 K and in air up to 570 K was examined for pressures from 1 to 25 bar. These data were used to further optimize the parameters in the FQY model representing collisional processes. The large quantity of data with 308 nm excitation allowed optimization of the nitrogen quenching rate, and data in air were used to optimize the oxygen quenching rate. These data were also used to optimize the vibrational relaxation parameters for nitrogen and oxygen. The model with the updated parameters is consistent with the data collected in the current work, as well as with fluorescence measurements made in optical ICEs up to 1100 K and 28 bar. Another area of tracer-based PLIF diagnostics development is time-resolved imaging. Because PLIF diagnostics are often performed using pulsed lasers, the time resolution of measurements is limited to the pulse rate of laser. Use of a high-powered visible laser with an off-the-shelf cavity frequency doubler is shown to produce a moderate-power CW beam in the ultraviolet wavelength regime. Application of this CW source to excite toluene, a high-FQY tracer, yields a sensitive, time-resolved tracer-based PLIF diagnostic. Fluctuation detection limits for tracer mole fraction were investigated by applying the diagnostic to an atmospheric temperature and pressure nitrogen jet seeded with 4% toluene, and detection limits of better than 1% of the maximum toluene mole fraction were achieved for detection of fluorescence signal at a point, along a line, and over a plane. The diagnostic was also demonstrated on a turbulent jet for line and planar detection and demonstrated the potential for toluene time-resolved PLIF diagnostics with CW lasers.

Filamentation Induced Nonlinear Optics

Download Filamentation Induced Nonlinear Optics PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 80 pages
Book Rating : 4.:/5 (918 download)

DOWNLOAD NOW!


Book Synopsis Filamentation Induced Nonlinear Optics by : Shuai Yuan

Download or read book Filamentation Induced Nonlinear Optics written by Shuai Yuan and published by . This book was released on 2014 with total page 80 pages. Available in PDF, EPUB and Kindle. Book excerpt: La filamentation du laser femtoseconde provient d'un équilibre dynamique entre l'autofocalisation Kerr et la défocalisation par le plasma autogénéré produit de l'ionisation multiphotonique/tunnel des molécules dans l'air. Ce phénomène a attiré beaucoup d'attention des scientifiques telles que la télédétection de polluants atmosphériques et l'identification moléculaire par l'alignement des molécules. Cependant, il y a une multitude de processus non linéaires lors de la filamentation. Quant à l'application, il est important d'avoir une compréhension des mécanismes physiques présents lors de la filamentation induite par l'optique non linéaire. Étant donné de nombreux de phénomènes et d'applications de la filamentation, cette thèse se concentre sur une partie de ces aspects. Ceux-ci sont la rotation de la polarisation laser dans les gaz atomiques/moléculaires, le processus d'émission laser des molécules d'eau dans l'étalonnage air, lde l'humidité à travers la spectroscopie induite par un filament, ainsi que le renforcement de la fluorescence par un réseau de diffraction de plasma. La rotation de la polarisation laser d'une sonde polarisée initialement linéaire a été étudié dans les gaz atomiques/moléculaires. Dans les gaz atomiques, la biréfringence ultrarapide induite par l'effet Kerr a été mesurée quantitativement. Dans les gaz moléculaires, la biréfringence et les états de polarisation de la production de la sonde ont été modulés à la renaissance rotationnelle de la molécule. Également, nous avons étudié expérimentalement la fluorescence induite par filament à partir des fragments dissociés dans l'air. Les émissions de fluorescence des radicaux libres OH à 308.9 nm et NH à 336.0 nm ont été observés dans l'air. La fluorescence rétrodiffusée par le groupement OH et le groupement NH présentait une augmentation exponentielle accompagnant l'augmentation de la longueur du filament qui indique l'existence de l'émission spontanée amplifiée (ASE). En plus, on étudie la spectroscopie de fluorescence induite par filament à partir du réseau de diffraction pour le plasma. Le réseau de diffraction pour le plasma a été généré par des filaments non colinéaires qui se superposés et synchronisés temporellement dans l'air. Une série de spectres des fragments excités du CN a été observée. L'intensité de fluorescence du radical CN en utilisant un réseau de diffraction par le plasma est beaucoup plus forte que celle utilisant des filaments séparés temporellement.

Laser-Aided Diagnostics of Plasmas and Gases

Download Laser-Aided Diagnostics of Plasmas and Gases PDF Online Free

Author :
Publisher : CRC Press
ISBN 13 : 1420034065
Total Pages : 307 pages
Book Rating : 4.4/5 (2 download)

DOWNLOAD NOW!


Book Synopsis Laser-Aided Diagnostics of Plasmas and Gases by : K Muraoka

Download or read book Laser-Aided Diagnostics of Plasmas and Gases written by K Muraoka and published by CRC Press. This book was released on 2016-04-19 with total page 307 pages. Available in PDF, EPUB and Kindle. Book excerpt: Updated and expanded from the original Japanese edition, Laser-Aided Diagnostics of Gases and Plasmas takes a unique approach in treating laser-aided diagnostics. The book unifies the subject by joining applications instead of describing each application as a totally separate system. In taking this approach, it highlights the relative strengths of

The Application of Laser Induced Fluorescence as a Plasma Diagnostic Technique

Download The Application of Laser Induced Fluorescence as a Plasma Diagnostic Technique PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 470 pages
Book Rating : 4.:/5 (22 download)

DOWNLOAD NOW!


Book Synopsis The Application of Laser Induced Fluorescence as a Plasma Diagnostic Technique by : Susan Hilary Law

Download or read book The Application of Laser Induced Fluorescence as a Plasma Diagnostic Technique written by Susan Hilary Law and published by . This book was released on 1986 with total page 470 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Laser-induced Fluorescence for Medical Diagnostics

Download Laser-induced Fluorescence for Medical Diagnostics PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 324 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Laser-induced Fluorescence for Medical Diagnostics by : Stefan Andersson-Engels

Download or read book Laser-induced Fluorescence for Medical Diagnostics written by Stefan Andersson-Engels and published by . This book was released on 1989 with total page 324 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Laser Induced Plasma Spectroscopy and Applications

Download Laser Induced Plasma Spectroscopy and Applications PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 258 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Laser Induced Plasma Spectroscopy and Applications by :

Download or read book Laser Induced Plasma Spectroscopy and Applications written by and published by . This book was released on 2002 with total page 258 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Mise au point de la fluorescence induite par diode laser résolue en temps

Download Mise au point de la fluorescence induite par diode laser résolue en temps PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (934 download)

DOWNLOAD NOW!


Book Synopsis Mise au point de la fluorescence induite par diode laser résolue en temps by : Mikaël Désécures

Download or read book Mise au point de la fluorescence induite par diode laser résolue en temps written by Mikaël Désécures and published by . This book was released on 2015 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: La pulvérisation cathodique magnétron est un procédé plasma très répandu dans l'industrie pour le dépôt de couches minces. Néanmoins, les exigences des nouvelles applications nécessitent de mieux comprendre, contrôler et maîtriser les processus fondamentaux gouvernant le transport de la matière pour optimiser le procédé. Ce travail de thèse porte sur l'étude du transport des atomes pulvérisés de tungstène (W) en décharge magnétron continu (DC direct current) et pulsée haute puissance (HiPIMS_high power impulse magnétron sputtering). La fluorescence induite par diode laser (TD-LIF) a été mise au point afin de mesurer les fonctions de distribution en vitesse des atomes W pulvérisés. Les mesures ont été calibrées par absorption laser et validées en corrélant avec les vitesses de dépôt. En procédé DC, l'étude de l'influence des paramètres de la décharge (puissance, tension, mélange gazeux Ar/He, distance par rapport à la cible, etc.) a mis en évidence l'évolution spatiale des régimes de transport balistique (atomes énergétiques), diffusif (atomes thermalisés), et mixte (balistique+diffusif). Pour l'étude du procédé HiPIMS, le plasma pulsé a nécessité de développer la TD-LIF résolue en temps (TR-TDLIF). Le degré de liberté supplémentaire qu'offre la dimension temporelle du plasma HiPIMS a permis de mieux comprendre le transport mixte qui représente le cas le plus compliqué. En effet, cela a permis de mesurer la cinétique du transport des atomes pulvérisés en ayant la possibilité de séparer les temps caractéristiques des différents processus.

Tracer-based Planar Laser-induced Fluorescence Diagnostics

Download Tracer-based Planar Laser-induced Fluorescence Diagnostics PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (718 download)

DOWNLOAD NOW!


Book Synopsis Tracer-based Planar Laser-induced Fluorescence Diagnostics by : Brian Ho-yin Cheung

Download or read book Tracer-based Planar Laser-induced Fluorescence Diagnostics written by Brian Ho-yin Cheung and published by . This book was released on 2011 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Two advances to tracer-based planar laser-induced fluorescence (PLIF) diagnostics are presented in this work. The first improvement is the development of a 3-pentanone fluorescence quantum yield (FQY) database and model for a wide range of conditions in support of quantitative PLIF diagnostics. In addition, this work presents a sensitive, time-resolved tracer-based PLIF diagnostic, accomplished by using a continuous-wave (CW) laser with the high-FQY tracer toluene. Because of its ease of use and desirable photophysical properties, PLIF diagnostics using 3-pentanone as a tracer are common, particularly for internal combustion engine (ICE) diagnostics. Thus, there is a need for 3-pentanone FQY measurements and modeling over a wide range of temperatures, pressures, and excitation wavelengths. For insight into the collisionless process in the FQY model, measurements were made in 3-pentanone vapor at low-pressures across a range of temperatures using a flowing cell. Laser excitation with 248, 266, 277, 308 nm wavelengths were utilized, and Rayleigh scattering of the laser beam was used to calibrate the optical efficiency of the collection optics and detector. This low-pressure data allows calculation of the 3-pentanone fluorescence rate and non-radiative de-excitation rate in the fluorescence model. The vibrational relaxation cascade parameter for 3-pentanone collisions was also determined. Measurements of 3-pentanone FQY were also made over a range of temperatures and pressures relevant to diagnostic applications, and, in particular, combined high-temperature and high-pressure conditions applicable to internal combustion engines (ICE). These data were collected in a custom-built optical cell capable of simultaneous high-pressure and high-temperature conditions. The behavior of the FQY in nitrogen for temperatures up to 745 K and in air up to 570 K was examined for pressures from 1 to 25 bar. These data were used to further optimize the parameters in the FQY model representing collisional processes. The large quantity of data with 308 nm excitation allowed optimization of the nitrogen quenching rate, and data in air were used to optimize the oxygen quenching rate. These data were also used to optimize the vibrational relaxation parameters for nitrogen and oxygen. The model with the updated parameters is consistent with the data collected in the current work, as well as with fluorescence measurements made in optical ICEs up to 1100 K and 28 bar. Another area of tracer-based PLIF diagnostics development is time-resolved imaging. Because PLIF diagnostics are often performed using pulsed lasers, the time resolution of measurements is limited to the pulse rate of laser. Use of a high-powered visible laser with an off-the-shelf cavity frequency doubler is shown to produce a moderate-power CW beam in the ultraviolet wavelength regime. Application of this CW source to excite toluene, a high-FQY tracer, yields a sensitive, time-resolved tracer-based PLIF diagnostic. Fluctuation detection limits for tracer mole fraction were investigated by applying the diagnostic to an atmospheric temperature and pressure nitrogen jet seeded with 4% toluene, and detection limits of better than 1% of the maximum toluene mole fraction were achieved for detection of fluorescence signal at a point, along a line, and over a plane. The diagnostic was also demonstrated on a turbulent jet for line and planar detection and demonstrated the potential for toluene time-resolved PLIF diagnostics with CW lasers.

Applications of Laser-induced Fluorescence to Medical Diagnostic Problems

Download Applications of Laser-induced Fluorescence to Medical Diagnostic Problems PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (11 download)

DOWNLOAD NOW!


Book Synopsis Applications of Laser-induced Fluorescence to Medical Diagnostic Problems by : S. J. Davis

Download or read book Applications of Laser-induced Fluorescence to Medical Diagnostic Problems written by S. J. Davis and published by . This book was released on 1991 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: