Mass Spectrometry for Uranium Isotopic Measurements

Download Mass Spectrometry for Uranium Isotopic Measurements PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 54 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Mass Spectrometry for Uranium Isotopic Measurements by : Charles Dewey Tabor

Download or read book Mass Spectrometry for Uranium Isotopic Measurements written by Charles Dewey Tabor and published by . This book was released on 1960 with total page 54 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Measurement of the Isotopic Enrichment of Uranium by a Direct Comparison Mass Spectrometer Method

Download Measurement of the Isotopic Enrichment of Uranium by a Direct Comparison Mass Spectrometer Method PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 40 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Measurement of the Isotopic Enrichment of Uranium by a Direct Comparison Mass Spectrometer Method by : V. L. Warren

Download or read book Measurement of the Isotopic Enrichment of Uranium by a Direct Comparison Mass Spectrometer Method written by V. L. Warren and published by . This book was released on 1958 with total page 40 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Mass Spectrometry for Uranium Isotopic Measurements. C. D. Tabor

Download Mass Spectrometry for Uranium Isotopic Measurements. C. D. Tabor PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 47 pages
Book Rating : 4.:/5 (459 download)

DOWNLOAD NOW!


Book Synopsis Mass Spectrometry for Uranium Isotopic Measurements. C. D. Tabor by : Agence internationale de l'énergie atomique

Download or read book Mass Spectrometry for Uranium Isotopic Measurements. C. D. Tabor written by Agence internationale de l'énergie atomique and published by . This book was released on 1960 with total page 47 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Uranium Isotope Measurements with a Model SU-1 Surface Ionization Mass Spectrometer

Download Uranium Isotope Measurements with a Model SU-1 Surface Ionization Mass Spectrometer PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 30 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Uranium Isotope Measurements with a Model SU-1 Surface Ionization Mass Spectrometer by : V. L. Warren

Download or read book Uranium Isotope Measurements with a Model SU-1 Surface Ionization Mass Spectrometer written by V. L. Warren and published by . This book was released on 1962 with total page 30 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Uranium Isotopic Standard Reference Materials

Download Uranium Isotopic Standard Reference Materials PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 168 pages
Book Rating : 4.:/5 (3 download)

DOWNLOAD NOW!


Book Synopsis Uranium Isotopic Standard Reference Materials by : E. L. Garner

Download or read book Uranium Isotopic Standard Reference Materials written by E. L. Garner and published by . This book was released on 1971 with total page 168 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Standard Reference Materials: Uranium Isotopic Standard Reference Materials

Download Standard Reference Materials: Uranium Isotopic Standard Reference Materials PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 166 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Standard Reference Materials: Uranium Isotopic Standard Reference Materials by : L. E. Garner

Download or read book Standard Reference Materials: Uranium Isotopic Standard Reference Materials written by L. E. Garner and published by . This book was released on 1971 with total page 166 pages. Available in PDF, EPUB and Kindle. Book excerpt:

An Automatic Mass Spectrometer for Relative Measurements of Uranium Isotopes

Download An Automatic Mass Spectrometer for Relative Measurements of Uranium Isotopes PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 24 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis An Automatic Mass Spectrometer for Relative Measurements of Uranium Isotopes by : A. Langdon

Download or read book An Automatic Mass Spectrometer for Relative Measurements of Uranium Isotopes written by A. Langdon and published by . This book was released on 1963 with total page 24 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Measurement of Impurity Effects in the Mass Spectrometer Isotopic Analysis of Uranium Hexafluoride

Download Measurement of Impurity Effects in the Mass Spectrometer Isotopic Analysis of Uranium Hexafluoride PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 24 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Measurement of Impurity Effects in the Mass Spectrometer Isotopic Analysis of Uranium Hexafluoride by : J. C. Horton

Download or read book Measurement of Impurity Effects in the Mass Spectrometer Isotopic Analysis of Uranium Hexafluoride written by J. C. Horton and published by . This book was released on 1958 with total page 24 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Mass Spectrometry for Uranium Isotope Measurements

Download Mass Spectrometry for Uranium Isotope Measurements PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 47 pages
Book Rating : 4.:/5 (32 download)

DOWNLOAD NOW!


Book Synopsis Mass Spectrometry for Uranium Isotope Measurements by : Charles Deivey Tabor

Download or read book Mass Spectrometry for Uranium Isotope Measurements written by Charles Deivey Tabor and published by . This book was released on 1960 with total page 47 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Mass Spectrometry for Uranium Isotope Measurements

Download Mass Spectrometry for Uranium Isotope Measurements PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 46 pages
Book Rating : 4.:/5 (224 download)

DOWNLOAD NOW!


Book Synopsis Mass Spectrometry for Uranium Isotope Measurements by : International Atomic Energy Agency

Download or read book Mass Spectrometry for Uranium Isotope Measurements written by International Atomic Energy Agency and published by . This book was released on with total page 46 pages. Available in PDF, EPUB and Kindle. Book excerpt:

The Determination of Uranium Isotope Abundances and Reactor Fuel Burnup by Mass Spectrometry

Download The Determination of Uranium Isotope Abundances and Reactor Fuel Burnup by Mass Spectrometry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 36 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis The Determination of Uranium Isotope Abundances and Reactor Fuel Burnup by Mass Spectrometry by : D. E. Fornwalt

Download or read book The Determination of Uranium Isotope Abundances and Reactor Fuel Burnup by Mass Spectrometry written by D. E. Fornwalt and published by . This book was released on 1963 with total page 36 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Isolation and Puification of Uranium Isotopes for Measurement by Mass-Spectrometry (233, 234, 235, 236, 238U) and Alpha Spectrometry (232U).

Download Isolation and Puification of Uranium Isotopes for Measurement by Mass-Spectrometry (233, 234, 235, 236, 238U) and Alpha Spectrometry (232U). PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 18 pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis Isolation and Puification of Uranium Isotopes for Measurement by Mass-Spectrometry (233, 234, 235, 236, 238U) and Alpha Spectrometry (232U). by :

Download or read book Isolation and Puification of Uranium Isotopes for Measurement by Mass-Spectrometry (233, 234, 235, 236, 238U) and Alpha Spectrometry (232U). written by and published by . This book was released on 2006 with total page 18 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report describes a standardized methodology used by researchers from the Center for Accelerator Mass Spectrometry (CAMS) (Energy and Environment Directorate) and the Environmental Radiochemistry Group (Chemistry and Materials Science Directorate) at the Lawrence Livermore National Laboratory (LLNL) for the full isotopic analysis of uranium from solution. The methodology has largely been developed for use in characterizing the uranium composition of selected nuclear materials but may also be applicable to environmental studies and assessments of public, military or occupational exposures to uranium using in-vitro bioassay monitoring techniques. Uranium isotope concentrations and isotopic ratios are measured using a combination of Multi Collector Inductively Coupled Plasma Mass Spectrometry (MC ICP-MS), Accelerator Mass Spectrometry (AMS) and Alpha Spectrometry.

Uranium Isotope Measurements by Quadrupole ICP-MS for Process Monitoring of Enrichment

Download Uranium Isotope Measurements by Quadrupole ICP-MS for Process Monitoring of Enrichment PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 13 pages
Book Rating : 4.:/5 (125 download)

DOWNLOAD NOW!


Book Synopsis Uranium Isotope Measurements by Quadrupole ICP-MS for Process Monitoring of Enrichment by : RN. Bolin

Download or read book Uranium Isotope Measurements by Quadrupole ICP-MS for Process Monitoring of Enrichment written by RN. Bolin and published by . This book was released on 1998 with total page 13 pages. Available in PDF, EPUB and Kindle. Book excerpt: Historically, uranium isotopic ratio measurements in the nuclear industry have been performed using Thermal Ionization Mass Spectrometry (TIMS); primarily due to the high level of precision that can be achieved. TIMS analysis, however, requires sample purification and intricate sample loading. Quadrupole (low resolution, single detector) inductively coupled plasma -- mass spectrometry, Q-ICP-MS, overcomes these disadvantages and is a cost-effective alternative, i.e., in terms of initial capital, maintenance, and operating costs. This paper presents a simple, single standard approach for measuring uranium isotope content in various solid and liquid nuclear materials along with some comparison data of Q-ICP-MS and TIMS. Intensity ratios of 234U, 235U, 236U, and 238U to total U intensity are produced, providing the enrichment level or percent 235U. A detailed description of the instrument and data collection parameters is also provided. Optimal precision and accuracy are achieved through the use of a single standard which is closely matched to the enrichment and concentration of the samples. Depending upon the standard chosen, enrichments between depleted and 97% can be quantified. Standard deviations for the major uranium isotopes are typically within 0.02 absolute and at least an order of magnitude lower for the minor U isotope abundances.

Developments in the Peaceful Applications of Nuclear Energy

Download Developments in the Peaceful Applications of Nuclear Energy PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (133 download)

DOWNLOAD NOW!


Book Synopsis Developments in the Peaceful Applications of Nuclear Energy by : C. D. Tabor

Download or read book Developments in the Peaceful Applications of Nuclear Energy written by C. D. Tabor and published by . This book was released on 1960 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

The Isotopic Ratio Measurement of Uranium in the Form of Hydrolyzed Uranium Hexafluoride by Inductively Coupled Plasma Multiple Collector Mass Spectrometry

Download The Isotopic Ratio Measurement of Uranium in the Form of Hydrolyzed Uranium Hexafluoride by Inductively Coupled Plasma Multiple Collector Mass Spectrometry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 6 pages
Book Rating : 4.:/5 (125 download)

DOWNLOAD NOW!


Book Synopsis The Isotopic Ratio Measurement of Uranium in the Form of Hydrolyzed Uranium Hexafluoride by Inductively Coupled Plasma Multiple Collector Mass Spectrometry by : T. Hodgson

Download or read book The Isotopic Ratio Measurement of Uranium in the Form of Hydrolyzed Uranium Hexafluoride by Inductively Coupled Plasma Multiple Collector Mass Spectrometry written by T. Hodgson and published by . This book was released on 1995 with total page 6 pages. Available in PDF, EPUB and Kindle. Book excerpt: An inductively coupled plasma-multiple collector-mass spectrometer (ICP-MC-MS) has been used to measure the isotopic composition of uranium in three solutions of uranium hexafluoride. The 235U: 238U ratio of each sample solution ranged from approximately 0.007 to 0.03 to 1.0. The measurements are linear over this range and the precision and accuracy are comparable, if not superior, to that obtained by thermal ionization mass spectrometry (TIMS). However, acceptable isotopic ratio measurement of uranium hexafluoride solutions is not possible by TIMS because the presence of fluoride ions severely limits analytical precision. Hence, the fluoride must be removed prior to analysis. This necessitates a chemical purification stage which adds both time and expense to the measurement process. This study reports direct, high precision, accurate uranium isotope ratio measurements on solutions of uranium hexafluoride. The instrumental time required for the analysis of 15 uranium samples with the ICP-MC-MS totals 135 min. This compares with an estimated time requirement of 600 min by TIMS and a time of 900 min by UF6 gas mass spectrometry.

Isotopes

Download Isotopes PDF Online Free

Author :
Publisher : Oxford University Press
ISBN 13 : 0198723628
Total Pages : 153 pages
Book Rating : 4.1/5 (987 download)

DOWNLOAD NOW!


Book Synopsis Isotopes by : Rob Ellam

Download or read book Isotopes written by Rob Ellam and published by Oxford University Press. This book was released on 2016 with total page 153 pages. Available in PDF, EPUB and Kindle. Book excerpt: Isotopes are used in many areas of science and technology, including medicine, archaeology, and nuclear physics. They are central to our understanding of the Earth's past and current processes. Here, Rob Ellam explains the importance and applications of stable and radioactive isotopes.

Quantifying Uranium Isotope Ratios Using Resonance Ionization Mass Spectrometry

Download Quantifying Uranium Isotope Ratios Using Resonance Ionization Mass Spectrometry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 512 pages
Book Rating : 4.:/5 (785 download)

DOWNLOAD NOW!


Book Synopsis Quantifying Uranium Isotope Ratios Using Resonance Ionization Mass Spectrometry by : Brett Hallen Isselhardt

Download or read book Quantifying Uranium Isotope Ratios Using Resonance Ionization Mass Spectrometry written by Brett Hallen Isselhardt and published by . This book was released on 2011 with total page 512 pages. Available in PDF, EPUB and Kindle. Book excerpt: Resonance Ionization Mass Spectrometry (RIMS) has been developed as a method to measure relative uranium isotope abundances. In this approach, RIMS is used as an element-selective ionization process to provide a distinction between uranium atoms and potential isobars without the aid of chemical purification and separation. We explore the laser parameters critical to the ionization process and their effects on the measured isotope ratio. Specifically, the use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of 235U/238U ratios to decrease laser-induced isotopic fractionation. By broadening the bandwidth of the first laser in a 3-color, 3-photon ionization process from a bandwidth of 1.8 GHz to about 10 GHz, the variation in sequential relative isotope abundance measurements decreased from>10% to less than 0.5%. This procedure was demonstrated for the direct interrogation of uranium oxide targets with essentially no sample preparation. A rate equation model for predicting the relative ionization probability has been developed to study the effect of variation in laser parameters on the measured isotope ratio. This work demonstrates that RIMS can be used for the robust measurement of uranium isotope ratios.