Ionization Collection in Detectors of the Cryogenic Dark Matter Search

Download Ionization Collection in Detectors of the Cryogenic Dark Matter Search PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 246 pages
Book Rating : 4.:/5 (957 download)

DOWNLOAD NOW!


Book Synopsis Ionization Collection in Detectors of the Cryogenic Dark Matter Search by : Arran Thomas James Phipps

Download or read book Ionization Collection in Detectors of the Cryogenic Dark Matter Search written by Arran Thomas James Phipps and published by . This book was released on 2016 with total page 246 pages. Available in PDF, EPUB and Kindle. Book excerpt: Determining the composition of dark matter is at the forefront of modern scientific research. There is compelling evidence for the existence of vast quantities of dark matter throughout the universe, however it has so-far eluded all direct detection efforts and its identity remains a mystery. Weakly interacting massive particles (WIMPs) are a favored dark matter candidate and have been the primary focus of direct detection for several decades. The Cryogenic Dark Matter Search (CDMS) has developed the Z-dependent Ionization and Phonon (ZIP) detector to search for such particles. Typically made from germanium, these detectors are capable of distinguishing between electromagnetic background and a putative WIMP signal through the simultaneous measurement of ionization and phonons produced by scattering events. CDMS has operated several arrays of these detectors at the Soudan Underground Laboratory (Soudan, MN, USA) resulting in many competitive (often world-leading) WIMP exclusion limits. This dissertation focuses on ionization collection in these detectors under the sub-Kelvin, low electric field, and high crystal purity conditions unique to CDMS. The design and performance of a fully cryogenic HEMT-based amplifier capable of achieving the SuperCDMS SNOLAB ionization energy resolution goal of 100 eVee is presented. The experimental apparatus which has been used to record electron and hole properties under CDMS conditions is described. Measurements of charge transport, trapping, and impact ionization as a function of electric field in two CDMS detectors are shown, and the ionization collection efficiency is determined. The data is used to predict the error in the nuclear recoil energy scale under both CDMSlite and iZIP operating modes. A two species, two state model is developed to describe how ionization collection and space charge generation in CDMS detectors are controlled by the presence of ``overcharged'' $D^-$ donor and $A^+$ acceptor impurity states. The thermal stability of these states is exclusive to sub-Kelvin operation, explaining why ionization collection in CDMS detectors differs from similar semiconductor detectors operating at higher temperature. This work represents a solid foundation for the understanding ionization collection in CDMS detectors.

Ionization Collection in Detectors of the Cryogenic Dark Matter Search

Download Ionization Collection in Detectors of the Cryogenic Dark Matter Search PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 246 pages
Book Rating : 4.:/5 (986 download)

DOWNLOAD NOW!


Book Synopsis Ionization Collection in Detectors of the Cryogenic Dark Matter Search by :

Download or read book Ionization Collection in Detectors of the Cryogenic Dark Matter Search written by and published by . This book was released on 2016 with total page 246 pages. Available in PDF, EPUB and Kindle. Book excerpt: Determining the composition of dark matter is at the forefront of modern scientific research. There is compelling evidence for the existence of vast quantities of dark matter throughout the universe, however it has so-far eluded all direct detection efforts and its identity remains a mystery. Weakly interacting massive particles (WIMPs) are a favored dark matter candidate and have been the primary focus of direct detection for several decades. The Cryogenic Dark Matter Search (CDMS) has developed the Z-dependent Ionization and Phonon (ZIP) detector to search for such particles. Typically made from germanium, these detectors are capable of distinguishing between electromagnetic background and a putative WIMP signal through the simultaneous measurement of ionization and phonons produced by scattering events. CDMS has operated several arrays of these detectors at the Soudan Underground Laboratory (Soudan, MN, USA) resulting in many competitive (often world-leading) WIMP exclusion limits. This dissertation focuses on ionization collection in these detectors under the sub-Kelvin, low electric field, and high crystal purity conditions unique to CDMS. The design and performance of a fully cryogenic HEMT-based amplifier capable of achieving the SuperCDMS SNOLAB ionization energy resolution goal of 100 eVee is presented. The experimental apparatus which has been used to record electron and hole properties under CDMS conditions is described. Measurements of charge transport, trapping, and impact ionization as a function of electric field in two CDMS detectors are shown, and the ionization collection efficiency is determined. The data is used to predict the error in the nuclear recoil energy scale under both CDMSlite and iZIP operating modes. A two species, two state model is developed to describe how ionization collection and space charge generation in CDMS detectors are controlled by the presence of "overcharged" D- donor and A+ acceptor impurity states. The thermal stability of these states is exclusive to sub-Kelvin operation, explaining why ionization collection in CDMS detectors differs from similar semiconductor detectors operating at higher temperature. This work represents a solid foundation for the understanding ionization collection in CDMS detectors.

The Cryogenic Dark Matter Search

Download The Cryogenic Dark Matter Search PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 286 pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis The Cryogenic Dark Matter Search by :

Download or read book The Cryogenic Dark Matter Search written by and published by . This book was released on 2010 with total page 286 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Cryogenic Dark Matter Search (CDMS) is searching for Weakly Interacting Massive Particles (WIMPs) with cryogenic particle detectors. These detectors have the ability to discriminate between nuclear recoil candidate and electron recoil background events by collecting both phonon and ionization energy from recoils in the detector crystals. The CDMS-II experiment has completed analysis of the first data runs with 30 semiconductor detectors at the Soudan Underground Laboratory, resulting in a world leading WIMP-nucleon spin-independent cross section limit for WIMP masses above 44 GeV/c2. As CDMS aims to achieve greater WIMP sensitivity, it is necessary to increase the detector mass and discrimination between signal and background events. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are surface and bulk trapping. Recent work has been focused on reducing surface trapping through the modification of fabrication methods for future detectors. Analyzing data taken with test devices has shown that hydrogen passivation of the amorphous silicon blocking layer worsens surface trapping. Additional data has shown that the iron-ion implantation used to lower the critical temperature of the tungsten transition-edge sensors causes a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and in situ at the experimental site have provided methods to optimize the neutralization process and monitor running conditions to maintain full ionization collection. This work details my contribution to the 5-tower data taking, monitoring, and analysis effort as well as the SuperCDMS detector development with the focus on monitoring and improving ionization collection in the detectors.

The Cryogenic Dark Matter Search: First 5-Tower Data and Improved Understanding of Ionization Collection

Download The Cryogenic Dark Matter Search: First 5-Tower Data and Improved Understanding of Ionization Collection PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 286 pages
Book Rating : 4.:/5 (495 download)

DOWNLOAD NOW!


Book Synopsis The Cryogenic Dark Matter Search: First 5-Tower Data and Improved Understanding of Ionization Collection by : Catherine N. Bailey

Download or read book The Cryogenic Dark Matter Search: First 5-Tower Data and Improved Understanding of Ionization Collection written by Catherine N. Bailey and published by . This book was released on 2010 with total page 286 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Cryogenic Dark Matter Search (CDMS) is searching for Weakly Interacting Massive Particles (WIMPs) with cryogenic particle detectors. These detectors have the ability to discriminate between nuclear recoil candidate and electron recoil background events by collecting both phonon and ionization energy from recoils in the detector crystals. The CDMS-II experiment has completed analysis of the Ơ̐1rst data runs with 30 semiconductor detectors at the Soudan Underground Laboratory, resulting in a world leading WIMP-nucleon spin-independent cross section limit for WIMP masses above 44 GeV/c^2. As CDMS aims to achieve greater WIMP sensitivity, it is necessary to increase the detector mass and discrimination between signal and background events. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are surface and bulk trapping. Recent work has been focused on reducing surface trapping through the modiƠ̐1cation of fabrication methods for future detectors. Analyzing data taken with test devices has shown that hydrogen passivation of the amorphous silicon blocking layer worsens surface trapping. Additional data has shown that the iron-ion implantation used to lower the critical temperature of the tungsten transition-edge sensors causes a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and in situ at the experimental site have provided methods to optimize the neutralization process and monitor running conditions to maintain full ionization collection. This work details my contribution to the 5-tower data taking, monitoring, and analysis eƠ̐0ort as well as the SuperCDMS detector development with the focus on monitoring and improving ionization collection in the detectors.

Results from the Two-tower Run of the Cryogenic Dark Matter Search

Download Results from the Two-tower Run of the Cryogenic Dark Matter Search PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 250 pages
Book Rating : 4.:/5 (319 download)

DOWNLOAD NOW!


Book Synopsis Results from the Two-tower Run of the Cryogenic Dark Matter Search by : Angela Jean Reisetter

Download or read book Results from the Two-tower Run of the Cryogenic Dark Matter Search written by Angela Jean Reisetter and published by . This book was released on 2005 with total page 250 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Optimizing the Design and Analysis of Cryogenic Semiconductor Dark Matter Detectors for Maximum Sensitivity

Download Optimizing the Design and Analysis of Cryogenic Semiconductor Dark Matter Detectors for Maximum Sensitivity PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (88 download)

DOWNLOAD NOW!


Book Synopsis Optimizing the Design and Analysis of Cryogenic Semiconductor Dark Matter Detectors for Maximum Sensitivity by : Matt Christopher Pyle

Download or read book Optimizing the Design and Analysis of Cryogenic Semiconductor Dark Matter Detectors for Maximum Sensitivity written by Matt Christopher Pyle and published by . This book was released on 2012 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: For the past 15 years, the Cryogenic Dark Matter Search or CDMS has searched for Weekly Interacting Massive Particle dark matter (WIMPs) using Ge and Si semiconductor crystals instrumented with both ionization and athermal phonon sensors so that the much more common electron recoil leakage caused by photons and [beta]s from naturally present radioactive elements can be easily distinguished from elastic WIMP nucleon interactions by looking at the fraction of total recoil energy which ends up as potential energy of e/h pairs. Due to electronic carrier trapping at the surface of our semiconductor crystals, electron recoils which occur near the surface have suppressed ionization measurements and can not be distinguished from WIMP induced nuclear recoils and thus sensitivity to the WIMP nucleon interaction cross section was driven in CDMS II by our ability to define a full 3D fiducial volume in which all events had full collection. To remain background free and maximally sensitive to the WIMPnucleus interaction cross section, we must improve our 3D fiducial volume definition at the same rate as we scale the mass of the detector, and thus proposed next generation experiments with an order of magnitude increase in active mass were unfortunately not possible with our previous CDMS II detector design, and a new design with significantly improved fiducialization performance is required. In this thesis, we illustrate how the complex E-field geometry produced by interdigitated electrodes at alternating voltage biases naturally encodes 3D fiducial volume information into the charge and phonon signals and thus is a natural geometry for our next generation dark matter detectors. Secondly, we will study in depth the physics of import to our devices including transition edge sensor dynamics, quasi- particle dynamics in our Al collection fins, and phonon physics in the crystal itself so that we can both understand the performance of our previous CDMS II device as well as optimize the design of our future devices. Of interest to the broader physics community is the derivation of the ideal athermal phonon detector resolution and it's cubic temperature scaling behavior which suggests that the athermal phonon detector technology developed by CDMS could also be used to discover coherent neutrino scattering and search for non-standard neutrino interaction and sterile neutrinos. These proposed resolution optimized devices can also be used in searches for exotic MeV-GeV dark matter as well as novel background free searches for 8GeV light WIMPs. Initial performance studies of our first two next generation iZIP detectors at the University of California Berkeley CDMS test facility indicate that electron recoil surface event misidentification is 2x10-5 ±2.5x10-5 (90%CL) for a recoil energy range of 8keVr-60keVr strongly indicating that z fiducial volume performance will not limit our WIMP sensitivity in next generation experiments. Furthermore, phonon only fiducial volume selections were created for nuclear recoil energies 2keVr suggesting that phonon only background free or background subtracting light WIMP mass experiments are potentially viable.

A Search for Particle Dark Matter Using Cryogenic Germanium and Silicon Detectors in the One- and Two- Tower Runs of CDMS-II at Soudan

Download A Search for Particle Dark Matter Using Cryogenic Germanium and Silicon Detectors in the One- and Two- Tower Runs of CDMS-II at Soudan PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 333 pages
Book Rating : 4.:/5 (727 download)

DOWNLOAD NOW!


Book Synopsis A Search for Particle Dark Matter Using Cryogenic Germanium and Silicon Detectors in the One- and Two- Tower Runs of CDMS-II at Soudan by :

Download or read book A Search for Particle Dark Matter Using Cryogenic Germanium and Silicon Detectors in the One- and Two- Tower Runs of CDMS-II at Soudan written by and published by . This book was released on 2008 with total page 333 pages. Available in PDF, EPUB and Kindle. Book excerpt: Images of the Bullet Cluster of galaxies in visible light, X-rays, and through gravitational lensing confirm that most of the matter in the universe is not composed of any known form of matter. The combined evidence from the dynamics of galaxies and clusters of galaxies, the cosmic microwave background, big bang nucleosynthesis, and other observations indicates that 80% of the universe's matter is dark, nearly collisionless, and cold. The identify of the dar, matter remains unknown, but weakly interacting massive particles (WIMPs) are a very good candidate. They are a natural part of many supersymmetric extensions to the standard model, and could be produced as a nonrelativistic, thermal relic in the early universe with about the right density to account for the missing mass. The dark matter of a galaxy should exist as a spherical or ellipsoidal cloud, called a 'halo' because it extends well past the edge of the visible galaxy. The Cryogenic Dark Matter Search (CDMS) seeks to directly detect interactions between WIMPs in the Milky Way's galactic dark matter halo using crystals of germanium and silicon. Our Z-sensitive ionization and phonon ('ZIP') detectors simultaneously measure both phonons and ionization produced by particle interactions. In order to find very rare, low-energy WIMP interactions, they must identify and reject background events caused by environmental radioactivity, radioactive contaminants on the detector, s and cosmic rays. In particular, sophisticated analysis of the timing of phonon signals is needed to eliminate signals caused by beta decays at the detector surfaces. This thesis presents the firs two dark matter data sets from the deep underground experimental site at the Soudan Underground Laboratory in Minnesota. These are known as 'Run 118', with six detectors (1 kg Ge, 65.2 live days before cuts) and 'Run 119', with twelve detectors (1.5 kg Ge, 74.5 live days before cuts). They have analyzed all data from the two runs together in a single, combined analysis, with sensitivity to lower-energy interactions, careful control of data quality and stability, and further development of techniques for reconstructing event location and rejecting near-surface interactions from beta decays. They also present a revision to the previously published Run 119 analysis, a demonstration of the feasibility of a low-threshold (1 or 2 keV) analysis of Soudan data, and a review of the literature on charge generation and quenching relevant to the ionization signal.

Development and Performance of Detectors for the Cryogenic Dark Matter Search Experiment with an Increased Sensitivity Based on a Maximum Likelihood Analysis of BetaContamination

Download Development and Performance of Detectors for the Cryogenic Dark Matter Search Experiment with an Increased Sensitivity Based on a Maximum Likelihood Analysis of BetaContamination PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 175 pages
Book Rating : 4.:/5 (316 download)

DOWNLOAD NOW!


Book Synopsis Development and Performance of Detectors for the Cryogenic Dark Matter Search Experiment with an Increased Sensitivity Based on a Maximum Likelihood Analysis of BetaContamination by : Donald D. Driscoll

Download or read book Development and Performance of Detectors for the Cryogenic Dark Matter Search Experiment with an Increased Sensitivity Based on a Maximum Likelihood Analysis of BetaContamination written by Donald D. Driscoll and published by . This book was released on 2004 with total page 175 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Cryogenic Dark Matter Search (CDMS) uses cryogenically-cooled detectors made of germanium and silicon in an attempt to detect dark matter in the form of Weakly-Interacting Massive Particles (WIMPs). The expected interaction rate of these particles is on the order of 1/kg/day, far below the 200/kg/day expected rate of background interactions after passive shielding and an active cosmic ray muon veto. Our detectors are instrumented to make a simultaneous measurement of both the ionization energy and thermal energy deposited by the interaction of a particle with the crystal substrate. A comparison of these two quantities allows for the rejection of a background of electromagnetically-interacting particles at a level of better than 99.9%. The dominant remaining background at a depth of {approx} 11 m below the surface comes from fast neutrons produced by cosmic ray muons interacting in the rock surrounding the experiment. Contamination of our detectors by a beta emitter can add an unknown source of unrejected background. In the energy range of interest for a WIMP study, electrons will have a short penetration depth and preferentially interact near the surface. Some of the ionization signal can be lost to the charge contacts there and a decreased ionization signal relative to the thermal signal will cause a background event which interacts at the surface to be misidentified as a signal event. We can use information about the shape of the thermal signal pulse to discriminate against these surface events. Using a subset of our calibration set which contains a large fraction of electron events, we can characterize the expected behavior of surface events and construct a cut to remove them from our candidate signal events. This thesis describes the development of the 6 detectors (4 x 250 g Ge and 2 x 100 g Si) used in the 2001-2002 CDMS data run at the Stanford Underground Facility with a total of 119 livedays of data. The preliminary results presented are based on the first use of a beta-eliminating cut based on a maximum-likelihood characterization described above.

The Cryogenic Dark Matter Search Low Ionization-threshold Experiment

Download The Cryogenic Dark Matter Search Low Ionization-threshold Experiment PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 165 pages
Book Rating : 4.:/5 (951 download)

DOWNLOAD NOW!


Book Synopsis The Cryogenic Dark Matter Search Low Ionization-threshold Experiment by :

Download or read book The Cryogenic Dark Matter Search Low Ionization-threshold Experiment written by and published by . This book was released on 2014 with total page 165 pages. Available in PDF, EPUB and Kindle. Book excerpt: Over 80 years ago we discovered the presence of Dark Matter in our universe. Endeavors in astronomy and cosmology are in consensus with ever improving precision that Dark Matter constitutes an essential 27% of our universe. The Standard Model of Particle Physics does not provide any answers to the Dark Matter problem. It is imperative that we understand Dark Matter and discover its fundamental nature. This is because, alongside other important factors, Dark Matter is responsible for formation of structure in our universe. The very construct in which we sit is defined by its abundance. The Milky Way galaxy, hence life, wouldn't have formed if small over densities of Dark Matter had not caused sufficient accretion of stellar material. Marvelous experiments have been designed based on basic notions to directly and in-directly study Dark Matter, and the Cryogenic Dark Matter Search (CDMS) experiment has been a pioneer and forerunner in the direct detection field. Generations of the CDMS experiment were designed with advanced scientific upgrades to detect Dark Matter particles of mass O(100) GeV/c2. This mass-scale was set primarily by predictions from Super Symmetry. Around 2013 the canonical SUSY predictions were losing some ground and several observations (rather hints of signals) from various experiments indicated to the possibility of lighter Dark Matter of mass O(10) GeV/c2. While the SuperCDMS experiment was probing the regular parameter space, the CDMSlite experiment was conceived to dedicatedly search for light Dark Matter using a novel technology. "CDMSlite" stands for CDMS - low ionization threshold experiment. Here we utilize a unique electron phonon coupling mechanism to measure ionization generated by scattering of light particles. Typically signals from such low energy recoils would be washed under instrumental noise. In CDMSlite via generation of Luke-Neganov phonons we can detect the small ionization energies, amplified in phonon modes during charge transport. This technology allows us to reach very low thresholds and reliably measure and investigate low energy recoils from light Dark Matter particles. This thesis describes the physics behind CDMSlite, the experimental design and the first science results from CDMSlite operated at the Soudan Underground Laboratory.

First Results from the Cryogenic Dark Matter Search Experiment at the Deep Site

Download First Results from the Cryogenic Dark Matter Search Experiment at the Deep Site PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 922 pages
Book Rating : 4.:/5 (34 download)

DOWNLOAD NOW!


Book Synopsis First Results from the Cryogenic Dark Matter Search Experiment at the Deep Site by : Vuk Mandic

Download or read book First Results from the Cryogenic Dark Matter Search Experiment at the Deep Site written by Vuk Mandic and published by . This book was released on 2004 with total page 922 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Comparing the Calibration and Simulation Data of the Cryogenic Dark Matter Search

Download Comparing the Calibration and Simulation Data of the Cryogenic Dark Matter Search PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 20 pages
Book Rating : 4.:/5 (873 download)

DOWNLOAD NOW!


Book Synopsis Comparing the Calibration and Simulation Data of the Cryogenic Dark Matter Search by :

Download or read book Comparing the Calibration and Simulation Data of the Cryogenic Dark Matter Search written by and published by . This book was released on 2011 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Cryogenic Dark Matter Search, or CDMS, collaboration is preparing a new experiment called SuperCDMS. CDMS uses Germanium detectors to attempt the direct detection of dark matter. To do this, they measure the ionization and heat produced during an event where a WIMP scatters off of germanium crystal lattice. To prepare for the experiment the detectors are calibrated with various radioactive sources. The response of the detectors is also modeled by a Monte Carlo simulation. These simulations include modeling everything from the radiation production to the raw data collected by the detector. The experimental data will be used to validate the results of the detector simulation. This research will look only at the phonons produced during events that occur very close to the detector surface. From the raw data and simulation output three parameters will be determined: the rise time, the decay time, and time to position independence. It was found that the simulation's risetime and time to position independence was generally smaller than that of the data, while the decay time was found to be larger in the simulation than in the data. These differences show that the simulation is not complete. The difference in risetime implies that the phonons are not spread out enough when they reach the detector walls, which would be improved by a look at the Luke phonon and charge transport. The long decay time in the simulation implies that the rate phonons are being absorbed is underestimated. Finally, the small time to position independence in the simulation could be due to a low phonon scattering rate. A simple solution may be to alter the parameters that control the simulation, while still remaining physically sensible, to help match simulation and data.

First Results from the Cryogenic Dark Matter Search Experiment at the Deep Site

Download First Results from the Cryogenic Dark Matter Search Experiment at the Deep Site PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 454 pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis First Results from the Cryogenic Dark Matter Search Experiment at the Deep Site by :

Download or read book First Results from the Cryogenic Dark Matter Search Experiment at the Deep Site written by and published by . This book was released on 2004 with total page 454 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Cryogenic Dark Matter Search (CDMS) experiment is designed to search for dark matter in the form of the Weakly Interacting Massive Particles (WIMPs). For this purpose, CDMS uses detectors based on crystals of Ge and Si, operated at the temperature of 20 mK, and providing a two-fold signature of an interaction: the ionization and the athermal phonon signals. The two signals, along with the passive and active shielding of the experimental setup, and with the underground experimental sites, allow very effective suppression and rejection of different types of backgrounds. This dissertation presents the commissioning and the results of the first WIMP-search run performed by the CDMS collaboration at the deep underground site at the Soudan mine in Minnesota. We develop different methods of suppressing the dominant background due to the electron-recoil events taking place at the detector surface and we apply these algorithms to the data set. These results place the world's most sensitive limits on the WIMP-nucleon spin-independent elastic-scattering cross-section. Finally, they examine the compatibility of the supersymmetric WIMP-models with the direct-detection experiments (such as CDMS) and discuss the implications of the new CDMS result on these models.

Development of New Cryogenic Low-threshold Detectors for the Search of Light Dark Matter and Low-energy Neutrino Physics

Download Development of New Cryogenic Low-threshold Detectors for the Search of Light Dark Matter and Low-energy Neutrino Physics PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (126 download)

DOWNLOAD NOW!


Book Synopsis Development of New Cryogenic Low-threshold Detectors for the Search of Light Dark Matter and Low-energy Neutrino Physics by : Dimitri Misiak

Download or read book Development of New Cryogenic Low-threshold Detectors for the Search of Light Dark Matter and Low-energy Neutrino Physics written by Dimitri Misiak and published by . This book was released on 2021 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Coherent Elastic Neutrino-Nucleus Scattering (CENNS) is a process predicted nearly 40 years ago. In August 2017, the COHERENT experiment reported the first keV-scale detection at the 6.7 sigma level of this process, which is a probe for the new low energy physics, opening a window on a myriad of new physics opportunities. The RICOCHET experiment aims at measuring with high accuracy the CENNS process in order to probe various exotic physics scenarios in the electroweak sector. Using cryogenic bolometers operated in a cryostat 8 meters away from the core of the ILL research nuclear reactor, the experiment will benefit from an intense neutrino flux, allowing the results of COHERENT to be reproduced in a single week. The objective of an accurate measurement will be achieved after one year of data collection, by 2024. The CRYOCUBE is a compact cubic array of cryogenic detectors with the following specifications: a very low energy threshold of O(10) eV on the thermal signal, an electromagnetic background rejection of at least 10^3 and a total target mass of 1 kg distributed among 27 germanium crystals of about 30 g each. The objective of this thesis is to propose an optimized detector design for the CRYOCUBE, inspired by the cryogenic germanium detectors equipped with charge and temperature readings of the direct dark matter search experiment EDELWEISS. This joint R&D program is based on event discrimination realized in germanium semiconductor crystals. The recoil energy of an incident particle is derived either from the increase of the crystal temperature measured by a GeNTD thermistor (heat channel) or from the excited electric charges collected by electrodes on its surface (ionization channel). This double energy measurement makes it possible to distinguish the nuclear recoils produced by the CENNS or the dark matter from the electronic radioactive background. As these recoils are of the order of O(100) eV, this thesis work is focused on the development of a new generation of cryogenic low threshold germanium detectors with particle identification. It explores how to improve the resolution in heat and ionization energy up to O(10) eV while maintaining a good rejection of background events. This study is based on the testing of prototype detectors in the IP2I cryostat, which are compared to theoretical predictions from electro-thermal and electrostatic modeling of the detectors. This manuscript begins with the definition of the CENNS process, its scientific importance and the objectives of the RICOCHET experiment. It then presents the cryogenic installation allowing the surface operation of the detectors at 20 mK in optimal conditions. An electro-thermal model of the bolometers, compared with experimental data, is developed and applied to the simulation of the noise associated with the electronics of the heat signal. The thesis then formalizes the generation of the ionization signals arising from excited charge carriers drifting in the germanium crystal under the influence of the applied electric field. The expected resolution from a future low-noise electronics is modeled based on two detector designs. They are optimized by their electrostatic simulation in a finite element calculation software. A comparison of the theoretical and experimental performance of ionization is performed on the basis of the RED80 and REDN1 prototype detectors. This work ends with the characterization of the radioactive background in the cryogenic laboratory with the analysis of the data from RED80, and in particular its neutron component, used to estimate the expected background at the ILL site for RICOCHET.

Phonon Quasidiffusion in Cryogenic Dark Matter Search Large Germanium Detectors

Download Phonon Quasidiffusion in Cryogenic Dark Matter Search Large Germanium Detectors PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 13 pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Phonon Quasidiffusion in Cryogenic Dark Matter Search Large Germanium Detectors by :

Download or read book Phonon Quasidiffusion in Cryogenic Dark Matter Search Large Germanium Detectors written by and published by . This book was released on 2012 with total page 13 pages. Available in PDF, EPUB and Kindle. Book excerpt: We present results on quasidiffusion studies in large, 3 inch diameter, 1 inch thick [100] high purity germanium crystals, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare data obtained in two different detector types, with different phonon sensor area coverage, with results from a Monte Carlo. The Monte Carlo includes phonon quasidiffusion and the generation of phonons created by charge carriers as they are drifted across the detector by ionization readout channels.

Detector Simulation and WIMP Search Analysis for the Cryogenic Dark Matter Search Experiment

Download Detector Simulation and WIMP Search Analysis for the Cryogenic Dark Matter Search Experiment PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 388 pages
Book Rating : 4.:/5 (865 download)

DOWNLOAD NOW!


Book Synopsis Detector Simulation and WIMP Search Analysis for the Cryogenic Dark Matter Search Experiment by : Kevin Ahmad McCarthy

Download or read book Detector Simulation and WIMP Search Analysis for the Cryogenic Dark Matter Search Experiment written by Kevin Ahmad McCarthy and published by . This book was released on 2013 with total page 388 pages. Available in PDF, EPUB and Kindle. Book excerpt: Astrophysical and cosmological measurements on the scales of galaxies, galaxy clusters, and the universe indicate that ~85% of the matter in the universe is composed of dark matter, made up of non-baryonic particles that interact with cross-sections on the weak scale or lower. Hypothetical Weakly Interacting Massive Particles, or WIMPs, represent a potential solution to the dark matter problem, and naturally arise in certain Standard Model extensions. The Cryogenic Dark Matter Search (CDMS) collaboration aims to detect the scattering of WIMP particles from nuclei in terrestrial detectors. Germanium and silicon particle detectors are deployed in the Soudan Underground Laboratory in Minnesota. These detectors are instrumented with phonon and ionization sensors, which allows for discrimination against electromagnetic backgrounds, which strike the detector at rates orders of magnitude higher than the expected WIMP signal. This dissertation presents the development of numerical models of the physics of the CDMS detectors, implemented in a computational package collectively known as the CDMS Detector Monte Carlo (DMC). After substantial validation of the models against data, the DMC is used to investigate potential backgrounds to the next iteration of the CDMS experiment, known as SuperCDMS. Finally, an investigation of using the DMC in a reverse Monte Carlo analysis of WIMP search data is presented. 140.23 kg-days of WIMP search data from the silicon detectors in the CDMSII experiment is also analyzed. The resulting upper limits on the WIMP-nucleon crosssection are higher than those published by other experiments at all WIMP masses, and the lowest limit on the WIMP-nucleon cross-section is 1.07*10-42 cm2 at a mass of 60 GeV/c2. These results do provide new and interesting constraints at WIMP masses

The Cryogenic Dark Matter Search Low Ionization-threshold Experiment

Download The Cryogenic Dark Matter Search Low Ionization-threshold Experiment PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (931 download)

DOWNLOAD NOW!


Book Synopsis The Cryogenic Dark Matter Search Low Ionization-threshold Experiment by :

Download or read book The Cryogenic Dark Matter Search Low Ionization-threshold Experiment written by and published by . This book was released on 2015 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

A Cryogenic Phonon Detector to Search for Dark Matter Particles

Download A Cryogenic Phonon Detector to Search for Dark Matter Particles PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 452 pages
Book Rating : 4.:/5 (33 download)

DOWNLOAD NOW!


Book Synopsis A Cryogenic Phonon Detector to Search for Dark Matter Particles by : Ning Wang

Download or read book A Cryogenic Phonon Detector to Search for Dark Matter Particles written by Ning Wang and published by . This book was released on 1991 with total page 452 pages. Available in PDF, EPUB and Kindle. Book excerpt: