ALTERNATE HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTRATION SYSTEM.

Download ALTERNATE HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTRATION SYSTEM. PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 190 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis ALTERNATE HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTRATION SYSTEM. by :

Download or read book ALTERNATE HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTRATION SYSTEM. written by and published by . This book was released on 2002 with total page 190 pages. Available in PDF, EPUB and Kindle. Book excerpt: In Phase IIA of this project, CeraMem has further developed and scaled up ceramic HEPA filters that are appropriate for use on filtration of vent gas from HLW tanks at DOE sites around the country. This work included procuring recrystallized SiC monoliths, developing membrane and cement materials, and defining a manufacturing process for the production of prototype full sizes HEPA filters. CeraMem has demonstrated that prototype full size filters can be manufactured by producing 9 full size filters that passed DOP aerosol testing at the Oak Ridge Filter Test Facility. One of these filters was supplied to the Savannah River Technical Center (SRTC) for process tests using simulated HLW tank waste. SRTC has reported that the filter was regenerable (with some increase in pressure drop) and that the filter retained its HEPA retention capability. CeraMem has also developed a Regenerable HEPA Filter System (RHFS) design and acceptance test plan that was reviewed by DOE personnel. The design and acceptance test plan form the basis of the system proposal for follow-on work in Phase IIB of this project.

High efficiency particulate air (HEPA) filters, Part 1: Performance and construction

Download High efficiency particulate air (HEPA) filters, Part 1: Performance and construction PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (138 download)

DOWNLOAD NOW!


Book Synopsis High efficiency particulate air (HEPA) filters, Part 1: Performance and construction by :

Download or read book High efficiency particulate air (HEPA) filters, Part 1: Performance and construction written by and published by . This book was released on with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Learning from SARS

Download Learning from SARS PDF Online Free

Author :
Publisher : National Academies Press
ISBN 13 : 0309182158
Total Pages : 376 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Learning from SARS by : Institute of Medicine

Download or read book Learning from SARS written by Institute of Medicine and published by National Academies Press. This book was released on 2004-04-26 with total page 376 pages. Available in PDF, EPUB and Kindle. Book excerpt: The emergence of severe acute respiratory syndrome (SARS) in late 2002 and 2003 challenged the global public health community to confront a novel epidemic that spread rapidly from its origins in southern China until it had reached more than 25 other countries within a matter of months. In addition to the number of patients infected with the SARS virus, the disease had profound economic and political repercussions in many of the affected regions. Recent reports of isolated new SARS cases and a fear that the disease could reemerge and spread have put public health officials on high alert for any indications of possible new outbreaks. This report examines the response to SARS by public health systems in individual countries, the biology of the SARS coronavirus and related coronaviruses in animals, the economic and political fallout of the SARS epidemic, quarantine law and other public health measures that apply to combating infectious diseases, and the role of international organizations and scientific cooperation in halting the spread of SARS. The report provides an illuminating survey of findings from the epidemic, along with an assessment of what might be needed in order to contain any future outbreaks of SARS or other emerging infections.

High efficiency particulate air (HEPA) filters, Part 2: Methods of test

Download High efficiency particulate air (HEPA) filters, Part 2: Methods of test PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (138 download)

DOWNLOAD NOW!


Book Synopsis High efficiency particulate air (HEPA) filters, Part 2: Methods of test by :

Download or read book High efficiency particulate air (HEPA) filters, Part 2: Methods of test written by and published by . This book was released on with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Requirements for Fire-Resistant High-Efficiency Particulate Air Filters

Download Requirements for Fire-Resistant High-Efficiency Particulate Air Filters PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 14 pages
Book Rating : 4.3/5 (91 download)

DOWNLOAD NOW!


Book Synopsis Requirements for Fire-Resistant High-Efficiency Particulate Air Filters by :

Download or read book Requirements for Fire-Resistant High-Efficiency Particulate Air Filters written by and published by . This book was released on 1966 with total page 14 pages. Available in PDF, EPUB and Kindle. Book excerpt:

High Efficiency Particulate Air (HEPA) Filter Generation, Characterization, and Disposal Experiences at the Oak Ridge National Laboratory

Download High Efficiency Particulate Air (HEPA) Filter Generation, Characterization, and Disposal Experiences at the Oak Ridge National Laboratory PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 10 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis High Efficiency Particulate Air (HEPA) Filter Generation, Characterization, and Disposal Experiences at the Oak Ridge National Laboratory by :

Download or read book High Efficiency Particulate Air (HEPA) Filter Generation, Characterization, and Disposal Experiences at the Oak Ridge National Laboratory written by and published by . This book was released on 2002 with total page 10 pages. Available in PDF, EPUB and Kindle. Book excerpt: High Efficiency Particulate Air filtration is an essential component of the containment and ventilation systems supporting the research and development activities at the Oak Ridge National Laboratory. High Efficiency Particulate Air filters range in size from 7.6cm (3 inch) by 10.2 cm (4 inch) cylindrical shape filters to filter array assemblies up to 2.1 m (7 feet) high by 1.5 m (5 feet) wide. Spent filters are grouped by contaminates trapped in the filter media and become one of the components in the respective waste stream. Waste minimization and pollution prevention efforts are applied for both radiological and non-radiological applications. Radiological applications include laboratory hoods, glove boxes, and hot cells. High Efficiency Particulate Air filters also are generated from intake or pre-filtering applications, decontamination activities, and asbestos abatement applications. The disposal avenues include sanitary/industrial waste, Resource Conservation and Recovery Act and Toxic Substance Control Act, regulated waste, solid low-level waste, contact handled transuranic, and remote handled transuranic waste. This paper discusses characterization and operational experiences associated with the disposal of the spent filters across multiple applications.

In-place HEPA (high Efficiency, Particulate Air) Filter Testing at Hanford

Download In-place HEPA (high Efficiency, Particulate Air) Filter Testing at Hanford PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 5 pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis In-place HEPA (high Efficiency, Particulate Air) Filter Testing at Hanford by :

Download or read book In-place HEPA (high Efficiency, Particulate Air) Filter Testing at Hanford written by and published by . This book was released on 1989 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt: High Efficiency, Particulate Air (HEPA) Filters provide a minimum of 99.97% removal efficiency for particles greater than or equal to .3 microns in diameter. Each HEPA filter installation at Hanford is, at specified intervals, functionally tested for leaks. The test procedure involves a dioctylphthalate (DOP) smoke generator and a calibrated airborne particle detector. The DOP generator produces smoke of a known quantitative particle size distribution upstream of the filter. The airborne particle detector is first placed upstream, and then downstream of the filter to determine percent penetration. The smoke generator is characterized using a calibrated laser spectrometer, and the particle detector is calibrated using a calibrated picoammeter. 2 refs., 4 figs.

Volume reduction of used high efficiency particulate air (HEPA) filters

Download Volume reduction of used high efficiency particulate air (HEPA) filters PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (141 download)

DOWNLOAD NOW!


Book Synopsis Volume reduction of used high efficiency particulate air (HEPA) filters by : O. I. Buttedahl

Download or read book Volume reduction of used high efficiency particulate air (HEPA) filters written by O. I. Buttedahl and published by . This book was released on 1981 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

High Efficiency Particulate Air (HEPA) Filters

Download High Efficiency Particulate Air (HEPA) Filters PDF Online Free

Author :
Publisher :
ISBN 13 : 9780733710605
Total Pages : 16 pages
Book Rating : 4.7/5 (16 download)

DOWNLOAD NOW!


Book Synopsis High Efficiency Particulate Air (HEPA) Filters by : Standards Association of Australia

Download or read book High Efficiency Particulate Air (HEPA) Filters written by Standards Association of Australia and published by . This book was released on 1997 with total page 16 pages. Available in PDF, EPUB and Kindle. Book excerpt:

High-efficiency Particulate Air Filters

Download High-efficiency Particulate Air Filters PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (957 download)

DOWNLOAD NOW!


Book Synopsis High-efficiency Particulate Air Filters by :

Download or read book High-efficiency Particulate Air Filters written by and published by . This book was released on 1974 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: High-efficiency particulate air (HEPA) filters now being manufactured commercially routinely exceed the specification of removing 99.97% of 0.3 mu - diameter particles of a monodisperse dioctyl phthalate (DOP) aerosol. Laboratory tests indicate that when such filters are properly installed in series, at least up to three, each will perform at this same level with plutonia aerosols, leading to decontamination factors in excess of 3 x 10/sup 10/. Filter media that are resistant to serious degradation by hydrogen fluoride and fluorine are now in the process of assembly into filter units for testing. (auth).

High-efficiency Particulate Air (HEPA) Filter Performance Following Service and Radiation Exposure

Download High-efficiency Particulate Air (HEPA) Filter Performance Following Service and Radiation Exposure PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis High-efficiency Particulate Air (HEPA) Filter Performance Following Service and Radiation Exposure by :

Download or read book High-efficiency Particulate Air (HEPA) Filter Performance Following Service and Radiation Exposure written by and published by . This book was released on 1974 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Viral Penetration of High Efficiency Particulate Air (HEPA) Filters

Download Viral Penetration of High Efficiency Particulate Air (HEPA) Filters PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 25 pages
Book Rating : 4.:/5 (227 download)

DOWNLOAD NOW!


Book Synopsis Viral Penetration of High Efficiency Particulate Air (HEPA) Filters by :

Download or read book Viral Penetration of High Efficiency Particulate Air (HEPA) Filters written by and published by . This book was released on 2007 with total page 25 pages. Available in PDF, EPUB and Kindle. Book excerpt: High Efficiency Particulate Air (HEPA) filters are the primary technology used for particulate removal in many individual and collective protection applications. HEPA filters are commonly thought to be impenetrable to particulate matter, but in fact they are only 99.97% efficient at collecting the most penetrating particle (~ 0.2 micrometer). While this is an impressive collection efficiency, HEPA filters may be vulnerable to certain types of threats: Viruses are submicron in size and most have very small minimum infections doses (MID). Therefore, an appropriate viral challenge will yield penetration that exceeds the MID, for many of the threat agent viruses. Nonetheless, the overall particle size (agglomerated viruses and/or viruses attached to inert carriers) will determine the capture efficiency by HEPA filters. Aerosolized viruses are commonly thought to exist as agglomerates, which would increase the particle size and render them more prone to capture. However many of the threat agent viruses can be highly agglomerated and still exist as submicron particles. Furthermore the stability of aggregates is not well understood, and they may break apart during filtration. We have demonstrated in our laboratory that biological aerosols of MS2 coli phage, a common viral simulant, can penetrate both Carbon HEPA Aerosol Canisters (CHAC) and flat sheet HEPA material. The penetration is linear over time, thus viral penetration exceeding the MID is expected to occur in minutes following a viral challenge. We are currently investigating the particle size of the MS2 coli phage aerosol and our aim is to shift the particle size to see what effect it has on penetration. Furthermore, we are evaluating the penetration characteristics of a mammalian virus, which may better represent the threat agent viruses.

Development of a Model Correlating Axial High Efficiency Particulate Air Filter Performance Between Elevated and Standard Conditions

Download Development of a Model Correlating Axial High Efficiency Particulate Air Filter Performance Between Elevated and Standard Conditions PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 106 pages
Book Rating : 4.:/5 (118 download)

DOWNLOAD NOW!


Book Synopsis Development of a Model Correlating Axial High Efficiency Particulate Air Filter Performance Between Elevated and Standard Conditions by : Michael Joseph Williston

Download or read book Development of a Model Correlating Axial High Efficiency Particulate Air Filter Performance Between Elevated and Standard Conditions written by Michael Joseph Williston and published by . This book was released on 2020 with total page 106 pages. Available in PDF, EPUB and Kindle. Book excerpt: The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow conditions. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to pressures from 14.70 psi to 11.25 psi, temperatures of 70°F to 170°F, and relative humidities of 50% to 90%. Evaluation of the effects of designating ACFM or SCFM are based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

Design and Set Up of a System for Testing HEPA Filter Efficiency

Download Design and Set Up of a System for Testing HEPA Filter Efficiency PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 32 pages
Book Rating : 4.:/5 (224 download)

DOWNLOAD NOW!


Book Synopsis Design and Set Up of a System for Testing HEPA Filter Efficiency by : Ken Alan Smigielski

Download or read book Design and Set Up of a System for Testing HEPA Filter Efficiency written by Ken Alan Smigielski and published by . This book was released on 2007 with total page 32 pages. Available in PDF, EPUB and Kindle. Book excerpt: High efficiency particulate air (HEPA) filters by definition have an air particle removal efficiency of

Criteria for Calculating the Efficiency of HEPA Filters During and After Design Basis Accidents

Download Criteria for Calculating the Efficiency of HEPA Filters During and After Design Basis Accidents PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 30 pages
Book Rating : 4.:/5 (683 download)

DOWNLOAD NOW!


Book Synopsis Criteria for Calculating the Efficiency of HEPA Filters During and After Design Basis Accidents by :

Download or read book Criteria for Calculating the Efficiency of HEPA Filters During and After Design Basis Accidents written by and published by . This book was released on 1994 with total page 30 pages. Available in PDF, EPUB and Kindle. Book excerpt: We have reviewed the literature on the performance of high efficiency particulate air (HEPA) filters under normal and abnormal conditions to establish criteria for calculating the efficiency of HEPA filters in a DOE nonreactor nuclear facility during and after a Design Basis Accident (DBA). The literature review included the performance of new filters and parameters that may cause deterioration in the filter performance such as filter age, radiation, corrosive chemicals, seismic and rough handling, high temperature, moisture, particle clogging, high air flow and pressure pulses. The deterioration of the filter efficiency depends on the exposure parameters; in severe exposure conditions the filter will be structurally damaged and have a residual efficiency of 0%. Despite the many studies on HEPA filter performance under adverse conditions, there are large gaps and limitations in the data that introduce significant error in the estimates of HEPA filter efficiencies under DBA conditions. Because of this limitation, conservative values of filter efficiency were chosen when there was insufficient data.

Phase I Characterization of the HEPA (High Efficiency Particulate Air) Filter Media Used in the Airborne Activity Confinement System at the Savannah River Site

Download Phase I Characterization of the HEPA (High Efficiency Particulate Air) Filter Media Used in the Airborne Activity Confinement System at the Savannah River Site PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (873 download)

DOWNLOAD NOW!


Book Synopsis Phase I Characterization of the HEPA (High Efficiency Particulate Air) Filter Media Used in the Airborne Activity Confinement System at the Savannah River Site by :

Download or read book Phase I Characterization of the HEPA (High Efficiency Particulate Air) Filter Media Used in the Airborne Activity Confinement System at the Savannah River Site written by and published by . This book was released on 1989 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of this report was to characterize the HEPA filter media material. This work consisted of two major tasks. First, the pressure drop characteristics of the HEPA filter material were measured as a function of the aerosol mass loading. Particle size effects were studied by using three different particle size distributions to load the filter material. The second task was to determine the filtration efficiency spectrum for solid particles as a function of particle diameter. The filtration efficiency was measured at two different media velocities, one corresponding to the equivalent flow rate under normal operating conditions, the other corresponding to the minimum equivalent flow rate expected through the filter compartments. These tests were conducted at the Argonne National Laboratory between September 1988 and February 1989. 20 refs., 31 figs., 10 tabs.

Criteria for Calculating the Efficiency of Deep-pleated HEPA Filters with Aluminum Separators During and After Design Basis Accidents

Download Criteria for Calculating the Efficiency of Deep-pleated HEPA Filters with Aluminum Separators During and After Design Basis Accidents PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 39 pages
Book Rating : 4.:/5 (683 download)

DOWNLOAD NOW!


Book Synopsis Criteria for Calculating the Efficiency of Deep-pleated HEPA Filters with Aluminum Separators During and After Design Basis Accidents by :

Download or read book Criteria for Calculating the Efficiency of Deep-pleated HEPA Filters with Aluminum Separators During and After Design Basis Accidents written by and published by . This book was released on 1995 with total page 39 pages. Available in PDF, EPUB and Kindle. Book excerpt: The authors have reviewed the literature on the performance of high efficiency particulate air (HEPA) filters under normal and abnormal conditions to establish criteria for calculating the efficiency of HEPA filters in a DOE nonreactor nuclear facility during and after a Design Basis Accident (DBA). This study is only applicable to the standard deep-pleated HEPA filter with aluminum separators as specified in ASME N509. The literature review included the performance of new filters and parameters that may cause deterioration in the filter performance such as filter age, radiation, corrosive chemicals, seismic and rough handling, high temperature, moisture, particle clogging, high air flow and pressure pulses. The deterioration of the filter efficiency depends on the exposure parameters; in severe exposure conditions the filter will be structurally damaged and have a residual efficiency of 0%. Despite the many studies on HEPA filter performance under adverse conditions, there are large gaps and limitations in the data that introduce significant error in the estimates of HEPA filter efficiencies under DBA conditions. Because of this limitation, conservative values of filter efficiency were chosen when there was insufficient data.