Criticality Safety Evaluation Report for the Cold Vacuum Drying (CVD) Facilities Process Water Handling System

Download Criticality Safety Evaluation Report for the Cold Vacuum Drying (CVD) Facilities Process Water Handling System PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 94 pages
Book Rating : 4.:/5 (16 download)

DOWNLOAD NOW!


Book Synopsis Criticality Safety Evaluation Report for the Cold Vacuum Drying (CVD) Facilities Process Water Handling System by :

Download or read book Criticality Safety Evaluation Report for the Cold Vacuum Drying (CVD) Facilities Process Water Handling System written by and published by . This book was released on 2000 with total page 94 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified.

Criticality Safety Evaluation Report for the Cold Vacuum Drying Facility's Process Water Handling System

Download Criticality Safety Evaluation Report for the Cold Vacuum Drying Facility's Process Water Handling System PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 47 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Criticality Safety Evaluation Report for the Cold Vacuum Drying Facility's Process Water Handling System by :

Download or read book Criticality Safety Evaluation Report for the Cold Vacuum Drying Facility's Process Water Handling System written by and published by . This book was released on 1999 with total page 47 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified.

Cold Vacuum Drying (CVD) Facility Hazards Analysis Report

Download Cold Vacuum Drying (CVD) Facility Hazards Analysis Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 91 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Cold Vacuum Drying (CVD) Facility Hazards Analysis Report by :

Download or read book Cold Vacuum Drying (CVD) Facility Hazards Analysis Report written by and published by . This book was released on 1999 with total page 91 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report describes the methodology used in conducting the Cold Vacuum Drying Facility (CVDF) hazard Analysis to support the CVDF Final Safety Analysis Report and documents the results. The hazard analysis was performed in accordance with DOE-STD-3009-94, ''Preparation Guide for US. Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports, '' and implements the requirements of DOE Order 5480.23, ''Nuclear Safety Analysis Reports.''

Cold Vacuum Drying (CVD) Facility Design Basis Accident Analysis Documentation

Download Cold Vacuum Drying (CVD) Facility Design Basis Accident Analysis Documentation PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 400 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Cold Vacuum Drying (CVD) Facility Design Basis Accident Analysis Documentation by :

Download or read book Cold Vacuum Drying (CVD) Facility Design Basis Accident Analysis Documentation written by and published by . This book was released on 1999 with total page 400 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the detailed accident analysis to support HNF-3553, Annex B, Spent Nuclear Fuel Project Final Safety Analysis Report (FSAR), ''Cold Vacuum Drying Facility Final Safety Analysis Report.'' All assumptions, parameters, and models used to provide the analysis of the design basis accidents are documented to support the conclusions in the FSAR. The calculations in this document address the design basis accidents (DBAs) selected for analysis in HNF-3553, ''Spent Nuclear Fuel Project Final Safety Analysis Report'', Annex B, ''Cold Vacuum Drying Facility Final Safety Analysis Report.'' The objective is to determine the quantity of radioactive particulate available for release at any point during processing at the Cold Vacuum Drying Facility (CVDF) and to use that quantity to determine the amount of radioactive material released during the DBAs. The radioactive material released is used to determine dose consequences to receptors at four locations, and the dose consequences are compared with the appropriate evaluation guidelines and release limits to ascertain the need for preventive and mitigative controls.

Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems

Download Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (852 download)

DOWNLOAD NOW!


Book Synopsis Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems by : C. Pili-Vincens

Download or read book Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems written by C. Pili-Vincens and published by . This book was released on 1998 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Preliminary Safety Evaluation for the Spent Nuclear Fuel Project's Cold Vacuum Drying System

Download Preliminary Safety Evaluation for the Spent Nuclear Fuel Project's Cold Vacuum Drying System PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 107 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Preliminary Safety Evaluation for the Spent Nuclear Fuel Project's Cold Vacuum Drying System by :

Download or read book Preliminary Safety Evaluation for the Spent Nuclear Fuel Project's Cold Vacuum Drying System written by and published by . This book was released on 1996 with total page 107 pages. Available in PDF, EPUB and Kindle. Book excerpt: This preliminary safety evaluation (PSE) considers only the Cold Vacuum Drying System (CVDS) facility and its mission as it relates to the integrated process strategy (WHC 1995). The purpose of the PSE is to identify those CBDS design functions that may require safety- class and safety-significant accident prevention and mitigation features.

Cold Vacuum Drying Facility Hazard Analysis Report

Download Cold Vacuum Drying Facility Hazard Analysis Report PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 99 pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis Cold Vacuum Drying Facility Hazard Analysis Report by :

Download or read book Cold Vacuum Drying Facility Hazard Analysis Report written by and published by . This book was released on 1998 with total page 99 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report describes the methodology used in conducting the Cold Vacuum Drying Facility (CVDF) hazard analysis to support the CVDF phase 2 safety analysis report (SAR), and documents the results. The hazard analysis was performed in accordance with DOE-STD-3009-94, Preparation Guide for US Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports, and implements the requirements of US Department of Energy (DOE) Order 5480.23, Nuclear Safety Analysis Reports.

Cold Vacuum Drying (CVD) Facility Sampling and Analysis Plan

Download Cold Vacuum Drying (CVD) Facility Sampling and Analysis Plan PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 20 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Cold Vacuum Drying (CVD) Facility Sampling and Analysis Plan by :

Download or read book Cold Vacuum Drying (CVD) Facility Sampling and Analysis Plan written by and published by . This book was released on 2000 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Cold Vacuum Drying (CVD) Facility provides the required process systems, supporting equipment, and facilities needed for the conditioning of spent nuclear fuel (SNF) from the Hanford K-Basins prior to storage at the Canister Storage Building (CSB). The process water conditioning (PWC) system collects and treats the selected liquid effluent streams generated by the CVD process. The PWC system uses ion exchange modules (IXMs) and filtration to remove radioactive ions and particulate from CVD effluent streams. Water treated by the PWC is collected in a 5000-gallon storage tank prior to shipment to an on-site facility for additional treatment and disposal. The purpose of this sampling and analysis plan is to document the basis for achieving the following data quality objectives: (1) Measurement of the radionuclide content of the water transferred from the multi-canister overpack (MCO), vacuum purge system (VPS) condensate tank, MCO/Cask annulus and deionized water flushes to the PWC system receiver tanks. (2) Trending the radionuclide inventory of IXMs to assure that they do not exceed the limits prescribed in HNF-2760, Rev. 0-D, ''Safety Analysis Report for Packaging (Onsite) Ion Exchange Modules, '' and HNF-EP-0063 Rev. 5, ''Hanford Site Solid Waste Acceptance Criteria'' for Category 3, non-TRU, low level waste (LLW). (3) Determining the radionuclide content of the PWC system bulk water storage tank to assure that it meets the limits set forth in HNF-3 172, Rev. 0, ''Hanford Site Liquid Waste Acceptance Criteria, '' to permit transfer and disposal at the Effluent Treatment Facility (ETF) located at the 200 East Area.

Estampes par ...

Download Estampes par ... PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (493 download)

DOWNLOAD NOW!


Book Synopsis Estampes par ... by :

Download or read book Estampes par ... written by and published by . This book was released on 1918 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Fire Hazard Analysis for the Cold Vacuum Drying Facility (CVD) Facility

Download Fire Hazard Analysis for the Cold Vacuum Drying Facility (CVD) Facility PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 346 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Fire Hazard Analysis for the Cold Vacuum Drying Facility (CVD) Facility by :

Download or read book Fire Hazard Analysis for the Cold Vacuum Drying Facility (CVD) Facility written by and published by . This book was released on 2000 with total page 346 pages. Available in PDF, EPUB and Kindle. Book excerpt: The CVDF is a nonreactor nuclear facility that will process the Spent Nuclear Fuels (SNF) presently stored in the 105-KE and 105-KW SNF storage basins. Multi-canister overpacks (MCOs) will be loaded (filled) with K Basin fuel transported to the CVDF. The MCOs will be processed at the CVDF to remove free water from the fuel cells (packages). Following processing at the CVDF, the MCOs will be transported to the CSB for interim storage until a long-term storage solution can be implemented. This operation is expected to start in November 2000. A Fire Hazard Analysis (FHA) is required for all new facilities and all nonreactor nuclear facilities, in accordance with U.S. Department of Energy (DOE) Order 5480.7A, Fire Protection. This FHA has been prepared in accordance with DOE 5480.7A and HNF-PRO-350, Fire Hazard Analysis Requirements. Additionally, requirements or criteria contained in DOE, Richland Operations Office (RL) RL Implementing Directive (RLID) 5480.7, Fire Protection, or other DOE documentation are cited, as applicable. This FHA comprehensively assesses the risk of fire at the CVDF to ascertain whether the specific objectives of DOE 5480.7A are met. These specific fire protection objectives are: (1) Minimize the potential for the occurrence of a fire. (2) Ensure that fire does not cause an onsite or offsite release of radiological and other hazardous material that will threaten the public health and safety or the environment. (3) Establish requirements that will provide an acceptable degree of life safety to DOE and contractor personnel and ensure that there are no undue hazards to the public from fire and its effects in DOE facilities. (4) Ensure that vital DOE programs will not suffer unacceptable delays as a result of fire and related perils. (5) Ensure that property damage from fire and related perils does not exceed an acceptable level. (6) Ensure that process control and safety systems are not damaged by fire or related perils. This FHA is based on the facility as constructed and with planned operation at the time of document preparation. Changes in facility planned and actual operation require that the identified fire risks associated with the CVDF be re-evaluated. Consequently, formal documentation and future revision of this FHA may be required.

Criticality Safety Evaluation for Dry Vacuum System Components

Download Criticality Safety Evaluation for Dry Vacuum System Components PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 9 pages
Book Rating : 4.:/5 (929 download)

DOWNLOAD NOW!


Book Synopsis Criticality Safety Evaluation for Dry Vacuum System Components by :

Download or read book Criticality Safety Evaluation for Dry Vacuum System Components written by and published by . This book was released on 1992 with total page 9 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying (CVD) Facility Master Equipment List

Download Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying (CVD) Facility Master Equipment List PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 134 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying (CVD) Facility Master Equipment List by :

Download or read book Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying (CVD) Facility Master Equipment List written by and published by . This book was released on 1999 with total page 134 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the master equipment list (MEL) for the Cold Vacuum Drying Facility (CVDF). The MEL was prepared to comply with DOE Standard 3024-98, Content of System Design Descriptions. The MEL was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems and the CVDF System Design Descriptions (SDD). The MEL identifies the SSCs and their safety functions, the design criteria, codes and standards, and quality assurance requirements that are required for establishing the safety design basis of the SSCs. The MEL also includes operating parameters, manufacturer information, and references the procurement specifications for the SSCs. This MEL shall be updated, expanded, and revised in accordance with future phases of the CVDF SAR, the SDD's, and CVDF operations.

Spent N Fuel Project Preliminary Safety Evaluation of the Cold Vacuum Drying System -- Calculations for the Flammable Gas Ignition Scenario

Download Spent N Fuel Project Preliminary Safety Evaluation of the Cold Vacuum Drying System -- Calculations for the Flammable Gas Ignition Scenario PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 19 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Spent N Fuel Project Preliminary Safety Evaluation of the Cold Vacuum Drying System -- Calculations for the Flammable Gas Ignition Scenario by :

Download or read book Spent N Fuel Project Preliminary Safety Evaluation of the Cold Vacuum Drying System -- Calculations for the Flammable Gas Ignition Scenario written by and published by . This book was released on 1996 with total page 19 pages. Available in PDF, EPUB and Kindle. Book excerpt: For a preliminary safety evaluation of the Cold Vacuum Drying System, calculations for the flammable gas ignition scenario are provided. Hydrogen buildup from uranium corrosion in the MCO followed by inadvertent injection of oxygen and the presence of an ignition source leads to hydrogen deflagration that over pressurizes and releases radioactive particulate matter to the environment. The adiabatic flame temperature, MCO pressure and source term are calculated.

Cold Vacuum Drying Residual Free Water Test Description

Download Cold Vacuum Drying Residual Free Water Test Description PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 70 pages
Book Rating : 4.:/5 (685 download)

DOWNLOAD NOW!


Book Synopsis Cold Vacuum Drying Residual Free Water Test Description by :

Download or read book Cold Vacuum Drying Residual Free Water Test Description written by and published by . This book was released on 1997 with total page 70 pages. Available in PDF, EPUB and Kindle. Book excerpt: Residual free water expected to remain in a Multi-Canister Overpack (MCO) after processing in the Cold Vacuum Drying (CVD) Facility is investigated based on three alternative models of fuel crevices. Tests and operating conditions for the CVD process are defined based on the analysis of these models. The models consider water pockets constrained by cladding defects, water constrained in a pore or crack by flow through a porous bed, and water constrained in pores by diffusion. An analysis of comparative reaction rate constraints is also presented indicating that a pressure rise test can be used to show MCO's will be thermally stable at operating temperatures up to 75 C.

Spent Nuclear Fuel Project Cold Vacuum Drying Facility Tempered Water and Tempered Water Cooling System Design Description

Download Spent Nuclear Fuel Project Cold Vacuum Drying Facility Tempered Water and Tempered Water Cooling System Design Description PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 68 pages
Book Rating : 4.:/5 (683 download)

DOWNLOAD NOW!


Book Synopsis Spent Nuclear Fuel Project Cold Vacuum Drying Facility Tempered Water and Tempered Water Cooling System Design Description by :

Download or read book Spent Nuclear Fuel Project Cold Vacuum Drying Facility Tempered Water and Tempered Water Cooling System Design Description written by and published by . This book was released on 1998 with total page 68 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the System Design Description (SDD) for the Cold Vacuum Drying Facility (CVDF) Tempered Water (TW) and Tempered Water Cooling (TWC) System . The SDD was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998), The HNF-SD-SNF-DRD-O02, 1998, Cold Vacuum Drying Facility Design Requirements, and the CVDF Design Summary Report. The SDD contains general descriptions of the TW and TWC equipment, the system functions, requirements and interfaces. The SDD provides references for design and fabrication details, operation sequences and maintenance. This SOD has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

Hanford Spent Nuclear Fuel Cold Vacuum Drying Proof of Performance Test Procedure

Download Hanford Spent Nuclear Fuel Cold Vacuum Drying Proof of Performance Test Procedure PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 102 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Hanford Spent Nuclear Fuel Cold Vacuum Drying Proof of Performance Test Procedure by :

Download or read book Hanford Spent Nuclear Fuel Cold Vacuum Drying Proof of Performance Test Procedure written by and published by . This book was released on 1998 with total page 102 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the test procedure for cold testing of the first article skids for the Cold Vacuum Drying (CVD) process at the Facility. The primary objective of this testing is to confirm design choices and provide data for the initial start-up parameters for the process. The current scope of testing in this document includes design verification, drying cycle determination equipment performance testing of the CVD process and MCC components, heat up and cool-down cycle determination, and thermal model validation.

Spent Nuclear Fuel Project Cold Vacuum Drying Facility Safety Equipment List

Download Spent Nuclear Fuel Project Cold Vacuum Drying Facility Safety Equipment List PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 63 pages
Book Rating : 4.:/5 (684 download)

DOWNLOAD NOW!


Book Synopsis Spent Nuclear Fuel Project Cold Vacuum Drying Facility Safety Equipment List by :

Download or read book Spent Nuclear Fuel Project Cold Vacuum Drying Facility Safety Equipment List written by and published by . This book was released on 1999 with total page 63 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the safety equipment list (SEL) for the Cold Vacuum Drying Facility (CVDF). The SEL was prepared in accordance with the procedure for safety structures, systems, and components (SSCs) in HNF-PRO-516, ''Safety Structures, Systems, and Components, '' Revision 0 and HNF-PRO-097, Engineering Design and Evaluation, Revision 0. The SEL was developed in conjunction with HNF-SO-SNF-SAR-O02, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998). The SEL identifies the SSCs and their safety functions, the design basis accidents for which they are required to perform, the design criteria, codes and standards, and quality assurance requirements that are required for establishing the safety design basis of the SSCs. This SEL has been developed for the CVDF Phase 2 Safety Analysis Report (SAR) and shall be updated, expanded, and revised in accordance with future phases of the CVDF SAR until the CVDF final SAR is approved.