COUPLAGE CHROMATOGRAPHIE EN PHASE LIQUIDE; DETECTION SPECTROFLUORIMETRIQUE ET APPLICATION AU DOSAGE DES AFLATOXINES CHROMATOGRAPHIE PAR ECHANGE DE LIGANDES (ACIDES AMINES, PEPTIDES)

Download COUPLAGE CHROMATOGRAPHIE EN PHASE LIQUIDE; DETECTION SPECTROFLUORIMETRIQUE ET APPLICATION AU DOSAGE DES AFLATOXINES CHROMATOGRAPHIE PAR ECHANGE DE LIGANDES (ACIDES AMINES, PEPTIDES) PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 101 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis COUPLAGE CHROMATOGRAPHIE EN PHASE LIQUIDE; DETECTION SPECTROFLUORIMETRIQUE ET APPLICATION AU DOSAGE DES AFLATOXINES CHROMATOGRAPHIE PAR ECHANGE DE LIGANDES (ACIDES AMINES, PEPTIDES) by : François Guyon

Download or read book COUPLAGE CHROMATOGRAPHIE EN PHASE LIQUIDE; DETECTION SPECTROFLUORIMETRIQUE ET APPLICATION AU DOSAGE DES AFLATOXINES CHROMATOGRAPHIE PAR ECHANGE DE LIGANDES (ACIDES AMINES, PEPTIDES) written by François Guyon and published by . This book was released on 1979 with total page 101 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Analyse par chromatographie en phase liquide couplée à la spectrométrie de masse d'acides aminés et de petits peptides non dérivés dans des matrices agroalimentaires

Download Analyse par chromatographie en phase liquide couplée à la spectrométrie de masse d'acides aminés et de petits peptides non dérivés dans des matrices agroalimentaires PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 280 pages
Book Rating : 4.:/5 (492 download)

DOWNLOAD NOW!


Book Synopsis Analyse par chromatographie en phase liquide couplée à la spectrométrie de masse d'acides aminés et de petits peptides non dérivés dans des matrices agroalimentaires by : Marine de Person

Download or read book Analyse par chromatographie en phase liquide couplée à la spectrométrie de masse d'acides aminés et de petits peptides non dérivés dans des matrices agroalimentaires written by Marine de Person and published by . This book was released on 2005 with total page 280 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'analyse qualitative et quantitative des acides aminés et des petits peptides dans les matrices complexes représente un enjeu indéniable dans de nombreux domaines d'application (agroalimentaire, pharmaceutique, exobiologie, ...). Les méthodes d'analyse que nous proposons dans ce mémoire font appel à la chromatographie en phase liquide couplée à la spectrométrie de masse sans étape de dérivation. La premiere partie du mémoire est consacrée à l'identification et au dosage de petits peptides dans des vins de Champagne. La méthodologie d'analyse est basée sur le couplage de la chromatographie de paire d'ions en milieu acide à la spectrométrie de masse à source electrospray en mode d'ionisation positif. Elle a été optimisée puis validée selon les critères classiques de validation. La seconde partie du mémoire a trait au développement de deux nouvelles méthodes séparatives complémentaires, compatibles avec un mode d'ionisation négatif. La première fait appel à la chromatographie de paire d'ions en milieu alcalin avec des agents d'appariement d'ions volatils (n-alkylammonium) sur silice greffée octadécyle et sur carbone graphitique poreux. La seconde utilise la chromatographie d'interactions hydrophiles sur une phase stationnaire polymérique de type amino. Une validation de ces méthodes a été développée. Enfin, une étude comparative des performances de deux sources d'ionisation de type electrospray associées à des interfaces différentes a été réalisée dans le cadre de l'analyse des acides aminés non dérivés.

COUPLAGE DE LA CHROMATOGRAPHIE EN PHASE LIQUIDE HAUTE PERFORMANCE A UN DETECTEUR A DIFFUSION DE LUMIERE

Download COUPLAGE DE LA CHROMATOGRAPHIE EN PHASE LIQUIDE HAUTE PERFORMANCE A UN DETECTEUR A DIFFUSION DE LUMIERE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (492 download)

DOWNLOAD NOW!


Book Synopsis COUPLAGE DE LA CHROMATOGRAPHIE EN PHASE LIQUIDE HAUTE PERFORMANCE A UN DETECTEUR A DIFFUSION DE LUMIERE by : LAURENCE.. DELEUZE

Download or read book COUPLAGE DE LA CHROMATOGRAPHIE EN PHASE LIQUIDE HAUTE PERFORMANCE A UN DETECTEUR A DIFFUSION DE LUMIERE written by LAURENCE.. DELEUZE and published by . This book was released on 2000 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Chromatographie liquide de haute performance en chimie des protéines

Download Chromatographie liquide de haute performance en chimie des protéines PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 226 pages
Book Rating : 4.:/5 (15 download)

DOWNLOAD NOW!


Book Synopsis Chromatographie liquide de haute performance en chimie des protéines by :

Download or read book Chromatographie liquide de haute performance en chimie des protéines written by and published by . This book was released on 1984 with total page 226 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Chromatographie par échange d'ions

Download Chromatographie par échange d'ions PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 80 pages
Book Rating : 4.:/5 (12 download)

DOWNLOAD NOW!


Book Synopsis Chromatographie par échange d'ions by : Félix François Busson

Download or read book Chromatographie par échange d'ions written by Félix François Busson and published by . This book was released on 1965 with total page 80 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Application du couplage chromatographie liquide-spectrométrie de masse à l'étude de la biodisponibilité de peptides issus de produits laitiers et à la protéomique

Download Application du couplage chromatographie liquide-spectrométrie de masse à l'étude de la biodisponibilité de peptides issus de produits laitiers et à la protéomique PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 252 pages
Book Rating : 4.:/5 (492 download)

DOWNLOAD NOW!


Book Synopsis Application du couplage chromatographie liquide-spectrométrie de masse à l'étude de la biodisponibilité de peptides issus de produits laitiers et à la protéomique by : François Delalande

Download or read book Application du couplage chromatographie liquide-spectrométrie de masse à l'étude de la biodisponibilité de peptides issus de produits laitiers et à la protéomique written by François Delalande and published by . This book was released on 2003 with total page 252 pages. Available in PDF, EPUB and Kindle. Book excerpt: Le couplage chromatographie liquide-spectrométrie de masse est devenu une méthode de choix pour la quantification de molécules dans une matrice, la détermination des séquences primaires de peptides et de protéines ainsi que la mise en évidence de modifications post-traductionnelles. Les progrès réalisés tant au niveau de la LC qu'au niveau de la spectrométrie de masse ont aussi révolutionné la biologie en permettant une identification sur des quantités femtomolaires de protéines séparées par électrophorèse bidimensionelle dans le cadre d'études protéomiques et la détection toujours plus sensible de molécules d'intérêt par exemple dans les fluides biologiques (plasma, urine, LCR).Mon travail de thèse a porté sur le choix et la mise au point de stratégies instrumentales et analytiques en optimisant de façon poussée tous les paramètres du couplage LC-MS et LC-MS-MS. La première partie concerne la mise au point expérimentale de techniques de microLC-MS et microLC-MS-MS pour la caractérisation de composés peptidiques et la mesure de leur biodisponibilité. La seconde partie porte sur le développement, l'optimisation et l'utilisation de la nano-LC-MS pour l'étude protéomique avec une première étude protéomique visant à caractériser les interactions entre le riz et le rice yellow mottle virus. Ce travail a permis par les techniques MALDI-MS et LC-MS-MS, de mettre en évidence les protéines du riz recrutées par les protéines de capside du virus et l'identification des protéines différentiellement exprimées selon la variété de riz (résistant/sensible). La seconde étude protéomique concerne la caractérisation de marqueurs d'expressions liés à l'anomalie "Mantled" chez le palmier à huile faisant appel au séquençage de novo. Pour conclure, nous avons utilisé les multiples potentiels du couplage microLC-MS et nanoLC-MS-MS pour répondre à différents problèmes biologiques. Ces réponses n'ont pu être obtenues que grâce à la mise au point de méthodologie particulière.