Comparison of Intraoral and Extraoral Scanners on the Accuracy of Digital Model Articulation

Download Comparison of Intraoral and Extraoral Scanners on the Accuracy of Digital Model Articulation PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 20 pages
Book Rating : 4.:/5 (992 download)

DOWNLOAD NOW!


Book Synopsis Comparison of Intraoral and Extraoral Scanners on the Accuracy of Digital Model Articulation by : Jason L. Porter

Download or read book Comparison of Intraoral and Extraoral Scanners on the Accuracy of Digital Model Articulation written by Jason L. Porter and published by . This book was released on 2017 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt: Introduction: Orthodontists increasingly rely on digital models in clinical practice. The ability of modern scanners to articulate digital models must be scientifically evaluated. Methods:Twenty five digital articulated models were produced from four digital scanners in five experimental groups. The resulting inter-arch measurements were compared to the gold standard. An acceptable range of 0.5mm more or less than the gold standard was used for evaluation. Results: iTero® and iTero® Element yielded all acceptable inter-arch measurements. The 3M"!True Definition and Ortho Insight 3D® with Regisil® bite registration produced four of six acceptable inter-arch measurements. The Ortho Insight 3D® with Coprwax "!bite registration yielded three of six acceptable inter-ach measurements. Conclusions: The iTero® and iTero® Element produced the most accurately articulated models. The 3M"!True Definition and Ortho Insight 3D® with Regisil® were the next most accurate. The Ortho Insight 3D® scanner with Coprwax "!was the least accurate method tested.

Digitization in Dentistry

Download Digitization in Dentistry PDF Online Free

Author :
Publisher : Springer Nature
ISBN 13 : 303065169X
Total Pages : 422 pages
Book Rating : 4.0/5 (36 download)

DOWNLOAD NOW!


Book Synopsis Digitization in Dentistry by : Priyanka Jain

Download or read book Digitization in Dentistry written by Priyanka Jain and published by Springer Nature. This book was released on 2021-03-22 with total page 422 pages. Available in PDF, EPUB and Kindle. Book excerpt: This book provides evidence-based guidance on the clinical applications of digital dentistry, that is, the use of dental technologies or devices that incorporate digital or computer-controlled components for the performance of dental procedures. Readers will find practically oriented information on the digital procedures currently in use in various fields of dental practice, including, for example, diagnosis and treatment planning, oral radiography, endodontics, orthodontics, implant dentistry, and esthetic dentistry. The aim is to equip practitioners with the knowledge required in order to enhance their daily practice. To this end, a problem-solving approach is adopted, with emphasis on key concepts and presentation of details in a sequential and easy to follow manner. Clear recommendations are set out, and helpful tips and tricks are highlighted. The book is written in a very readable style and is richly illustrated. Whenever appropriate, information is presented in tabular form to provide a ready overview of answers to frequent doubts and questions.

Accuracy of Digital Models Acquired from Two Different Intraoral Scanners

Download Accuracy of Digital Models Acquired from Two Different Intraoral Scanners PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 70 pages
Book Rating : 4.:/5 (15 download)

DOWNLOAD NOW!


Book Synopsis Accuracy of Digital Models Acquired from Two Different Intraoral Scanners by : Jessie Marie Kierl

Download or read book Accuracy of Digital Models Acquired from Two Different Intraoral Scanners written by Jessie Marie Kierl and published by . This book was released on 2018 with total page 70 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Digital Intraoral Scanners Vs Traditional Impressions- Fitting Accuracy of Screwed Mesostructures

Download Digital Intraoral Scanners Vs Traditional Impressions- Fitting Accuracy of Screwed Mesostructures PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (116 download)

DOWNLOAD NOW!


Book Synopsis Digital Intraoral Scanners Vs Traditional Impressions- Fitting Accuracy of Screwed Mesostructures by : Carlesi Gian Luca

Download or read book Digital Intraoral Scanners Vs Traditional Impressions- Fitting Accuracy of Screwed Mesostructures written by Carlesi Gian Luca and published by . This book was released on 2017 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: TitleDigital intraoral scanners vs traditional impressions: Fitting accuracy of screwed mesostructuresBackgroundPassive fit and marginal precision of prosthetic structures on osteointegrated implants are a requirement to minimize tensions and to avoid loss of marginal bone and finally lack of osteointegration. The impression process is a primary step to obtain sufficient accuracy.We use daily intraoral scanners for impressions to made implant restorations from several years and we appreciate the clinical outcomes for passive fitting (cemented sovrastructures) and precision of screwed ones.AimThe aim of this job is to investigate the marginal accuracy of custom CoCr milled mesostructures on implants acquiring impressions by intraoral digital scanners and compare them to ones obtained bytraditional impressions systems and to evaluate if the misfit is within the optimal measure of 25-50u00b5m.Material and methodsTwo pair of implants were rigidly fixed in maxilla resin models. The first two implant were internal hexagonal flat connection implants made by Winsix implant system ( Biosaf In srl). The second two were internal octagonal conical connection implants made by Geass (Geass srl). Three impressions were took of each model. The first one was a traditional impression made by polyether material with the single impression technique. The other two impression was acquired using CS3500 Carestream Intraoral Scanner and Trios3 intraoral scanner. The digital impressions were made following factory recommendations for implant cases workflow.Milled CoCr screwed mesostructures were commissioned on the three impressions of each model.The aim was to analyze the misfit of the three mesostructures obtained using Sheffield test. The misfit was evaluated by a radiograph taken perpendicularly to the long axis of the implants. ImageJu00ae software was used to digitally process the radiographic images and perform the measurements. ResultsWe eliminate, using an artificial model some intraoral variables as blood, saliva, patient movements but we simulate the natural architecture of mouth maintaining crestal anatomy, gum, implant distance. We investigate the misfit radiographically performing the Scheffield test: in this way we screwed firmly only one screw of the mesostructure and we observe the matching of the other implant-structure connection.The bigger misfit was appreciate on the two mesostructures obtained by traditional impressions, one of them has failed to comply with the established gap limit of 50 u00b5m.Very good fitting, within the limit of 50 u00b5m was found on three mesostructures: The one made by impression with Carestream intraoral scanner CS3500 on winsix implantsand the two performed by Trios3 intraoral scanner 3Shapedental on Winsix implants and Geass Way implantsThe fitting accuracy of the last mesostructure made by impression performed on Geass Way implants with CS3500 scanner looks a middle way.ConclusionsThe misfit of all the mesostructures obtained by digital intraoral scanners seems to be in the safety range, avoiding structural tensions involving implant after screwing.This study confirm the fitting accuracy of milled mesostructures obtainable by digital intraoral impressions.We expected a more homogeneous results in the group of mesostructures obtained by digital impressions, poor number of mesostructures investigated may be the reason of the discrepancy.More data are indispensable to complete the results obtained and to investigate the real accuracy obtainable .

A Comparison of Digital Intraoral Scanners and Alginate Impressions: Time & Patient Satisfaction

Download A Comparison of Digital Intraoral Scanners and Alginate Impressions: Time & Patient Satisfaction PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 47 pages
Book Rating : 4.:/5 (99 download)

DOWNLOAD NOW!


Book Synopsis A Comparison of Digital Intraoral Scanners and Alginate Impressions: Time & Patient Satisfaction by : Jennifer Ann Burzynski

Download or read book A Comparison of Digital Intraoral Scanners and Alginate Impressions: Time & Patient Satisfaction written by Jennifer Ann Burzynski and published by . This book was released on 2017 with total page 47 pages. Available in PDF, EPUB and Kindle. Book excerpt: Introduction: Impressions play an important role in dentistry and its specialties. Recent technological advances have made intraoral scans and digital models a possibility, and a promising alternative to conventional alginate impressions. Several factors should be examined when considering an intraoral scanner, including patient acceptance and efficiency. The objectives of this study were to assess and compare patient satisfaction and time required among two intraoral scanners and conventional alginate impressions. Methods: An initial pilot study was completed to create a valid and reliable survey instrument which would measure three areas of patient satisfaction with the impression experience. Following the survey development, the questionnaire was administered to orthodontic patients receiving one of three types of impressions, and the time required to obtain the impressions was recorded. Results: Reliability was evaluated with ICC values for 17 paired questionnaires, and all questions were found to be reliable (ICC = 0.65). For the main study, 180 subjects completed timed impressions and surveys. Data indicated that subjects receiving intraoral scans preferred the digital impressions while subjects receiving alginate impressions were neutral regarding impression preference, and that efficiency varied based on impression method. Conclusions: Intraoral scanners are accepted by orthodontic patients, and they have comparable efficiency to conventional impression methods depending on type of scanner.

Molar Incisor Hypomineralization

Download Molar Incisor Hypomineralization PDF Online Free

Author :
Publisher : Springer Nature
ISBN 13 : 3030316017
Total Pages : 205 pages
Book Rating : 4.0/5 (33 download)

DOWNLOAD NOW!


Book Synopsis Molar Incisor Hypomineralization by : Katrin Bekes

Download or read book Molar Incisor Hypomineralization written by Katrin Bekes and published by Springer Nature. This book was released on 2020-01-03 with total page 205 pages. Available in PDF, EPUB and Kindle. Book excerpt: This book is a wide-ranging reference on current clinical and scientific knowledge regarding the various aspects of molar incisor hypomineralization (MIH). Background information is first presented on the structural properties of hypomineralized enamel, the prevalence of MIH, and potential etiological factors. Subsequent chapters focus on key considerations in clinical practice. Diagnostic criteria, classifications, and treatment strategies are discussed and detailed attention is devoted to potential associations between MIH and caries, the occurrence of hypomineralized primary teeth, and the knowledge and experience of dentists concerning MIH. In the last part of the book, the different treatment options are systematically presented and reviewed, covering pain control, prophylaxis and desensitization, fissure sealing, direct and indirect restorations, and extraction therapy. The cost-effectiveness of the available procedures is also considered. The book is written by acknowledged international experts in the field and will be an ideal source of up-to-date information and guidance for both dental professionals and postgraduate students.

Dental Biomaterials, An Issue of Dental Clinics of North America, E-Book

Download Dental Biomaterials, An Issue of Dental Clinics of North America, E-Book PDF Online Free

Author :
Publisher : Elsevier Health Sciences
ISBN 13 : 0323848974
Total Pages : 209 pages
Book Rating : 4.3/5 (238 download)

DOWNLOAD NOW!


Book Synopsis Dental Biomaterials, An Issue of Dental Clinics of North America, E-Book by : Jack Ferracane

Download or read book Dental Biomaterials, An Issue of Dental Clinics of North America, E-Book written by Jack Ferracane and published by Elsevier Health Sciences. This book was released on 2022-10-12 with total page 209 pages. Available in PDF, EPUB and Kindle. Book excerpt: In this issue of Dental Clinics, guest editors Drs. Jack L. Ferracane, Luiz E. Bertassoni, and Carmem S. Pfeifer bring their considerable expertise to the topic of Dental Biomaterials. Dental biomaterials have received recent attention in terms of exhibiting excellent performance, as well as increased migration and proliferation of cells involved in the osseointegration of implants. This issue offers up-to-date, expert coverage of adhesives, cements, composites, ceramics, scaffold materials, and implants, as well as light curing and safety of dental materials. Contains 11 practice-oriented topics including dental adhesives: surface modifications of tooth structure for stable bonding; resin-based composites: materials for direct and indirect applications; new technologies for restorative dentistry; advances in ceramics for dental applications; cements and protocols for bonded dental ceramics; and more. Provides in-depth clinical reviews on dental biomaterials, offering actionable insights for clinical practice. Presents the latest information on this timely, focused topic under the leadership of experienced editors in the field. Authors synthesize and distill the latest research and practice guidelines to create clinically significant, topic-based reviews.

Comparing the Accuracy of Intra-oral Scanners for Implant Level Impressions Using Different Scanable Abutments

Download Comparing the Accuracy of Intra-oral Scanners for Implant Level Impressions Using Different Scanable Abutments PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 69 pages
Book Rating : 4.:/5 (93 download)

DOWNLOAD NOW!


Book Synopsis Comparing the Accuracy of Intra-oral Scanners for Implant Level Impressions Using Different Scanable Abutments by : Nakul H. Rathi

Download or read book Comparing the Accuracy of Intra-oral Scanners for Implant Level Impressions Using Different Scanable Abutments written by Nakul H. Rathi and published by . This book was released on 2014 with total page 69 pages. Available in PDF, EPUB and Kindle. Book excerpt: The calculated differences (mm3) were analyzed using a repeated-measures muiltifactorial ANOVA and Tukey-test, with an alpha level=0.05, with a non-directional alpha risk of 0.05. Post-hoc comparison was done showing all the possible combination of the variable types. Four actual CAD bars were milled through the CAM process and compared to the digital analysis.

Accuracy and Precision of Two Intraoral Scanners in Oral Implantology- in Vitro Analysis of the Lower Jaw Model with 4 Scan Bodies

Download Accuracy and Precision of Two Intraoral Scanners in Oral Implantology- in Vitro Analysis of the Lower Jaw Model with 4 Scan Bodies PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (116 download)

DOWNLOAD NOW!


Book Synopsis Accuracy and Precision of Two Intraoral Scanners in Oral Implantology- in Vitro Analysis of the Lower Jaw Model with 4 Scan Bodies by : Jelena Dujoviu0107

Download or read book Accuracy and Precision of Two Intraoral Scanners in Oral Implantology- in Vitro Analysis of the Lower Jaw Model with 4 Scan Bodies written by Jelena Dujoviu0107 and published by . This book was released on 2017 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Limited informations are available about the accuracy and precision of intraoral scanners when they are applied in implantology, especially by edentulous jaws. Compare the accuracy and precision of two intraoral scanner and determine the impact of dentist's skills on scanning results were the golas of stady. Stone model with four implant analogues (Straumannu00ae) and polyether-ether-ketone (PEEK) scan bodies was digitized with: industrial scanner (Atos Core 135 - used as a reference) and with two intraoral scanners (Triosu00ae; Omnicamu00ae).Four dentists scanned stone model in accordance with recommended scan protocol. Intraoral scans were superimposed on the reference model, to evaluate accuracy. All scanns superimposed on each other within groups, to evaluate precision.Triosu00ae has a higher degree of precision and accuracy compared to Omnicamu00ae.The study indicate that the dentist's skill has important impact on the measurement results.

Comparing the Accuracy of Intraoral Scanners, Using Advanced Micro Computed Tomography

Download Comparing the Accuracy of Intraoral Scanners, Using Advanced Micro Computed Tomography PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (139 download)

DOWNLOAD NOW!


Book Synopsis Comparing the Accuracy of Intraoral Scanners, Using Advanced Micro Computed Tomography by : Mattia Sacher

Download or read book Comparing the Accuracy of Intraoral Scanners, Using Advanced Micro Computed Tomography written by Mattia Sacher and published by . This book was released on 2020* with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Digital Workflow in Reconstructive Dentistry

Download Digital Workflow in Reconstructive Dentistry PDF Online Free

Author :
Publisher : Quintessenz Verlag
ISBN 13 : 3868675515
Total Pages : 467 pages
Book Rating : 4.8/5 (686 download)

DOWNLOAD NOW!


Book Synopsis Digital Workflow in Reconstructive Dentistry by : Wael Att

Download or read book Digital Workflow in Reconstructive Dentistry written by Wael Att and published by Quintessenz Verlag. This book was released on 2021-02-01 with total page 467 pages. Available in PDF, EPUB and Kindle. Book excerpt: Digital Workflow in Reconstructive Dentistry is the result of efforts made by the academic team at the Department of Prosthodontics, University Hospital of Freiburg. It aims to build a fundamental understanding of the general principles, science, and clinics of digital dental medicine. The information provided within these pages summarizes the various components of the digital workflow in reconstructive dentistry and discusses their advantages and disadvantages. Moreover, insights are provided about upcoming, game-changing technologies. By reading this book, students, clinicians, and researchers will gain and enhance their knowledge about digital dental medicine and identify the areas they need to focus on next in order to integrate the available technologies in their daily work. Clearly, the path of digital dental medicine will not stop here. Contributors Amirah M. R. Alammar • Abdulaziz Alsahaf • Wael Att • Maria Bateli • Jasmin Bernhart • Shaza Bishti • Sarah Blattner • Miha Brezavšček • Sandy Cepa • Nadine Emmanoulidi • Ahmed Fawzy • Manrique Fonseca • Michele Frapporti • Rumpa Ganguly • Yousef Al-Ghamdi • Petra Ch. Gierthmuehlen • Aiste Gintaute • Ulrich Lamott • Christos Lamprinos • Matthias Petsch • Udo Plaster • Aikaterini Ploumaki • Hanna Rauberger • Elisabeth Schwartzkopff • Christian F. Selz • Thamer Al-Sharif • Benedikt Spies • Frank A. Spitznagel • Jörg R. Strub • Michael Swain • Taskin Tuna • Alexander Vuck • Siegbert Witkowski

Linear Evaluation and Comparison of Traditional Orthodontic Plaster Models Versus Digital Models Obtained Through Intraoral Scanning

Download Linear Evaluation and Comparison of Traditional Orthodontic Plaster Models Versus Digital Models Obtained Through Intraoral Scanning PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 57 pages
Book Rating : 4.:/5 (8 download)

DOWNLOAD NOW!


Book Synopsis Linear Evaluation and Comparison of Traditional Orthodontic Plaster Models Versus Digital Models Obtained Through Intraoral Scanning by : Tyler E. Prentice

Download or read book Linear Evaluation and Comparison of Traditional Orthodontic Plaster Models Versus Digital Models Obtained Through Intraoral Scanning written by Tyler E. Prentice and published by . This book was released on 2010 with total page 57 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Accuracy of Various Intraoral Digital Impression Techniques

Download Accuracy of Various Intraoral Digital Impression Techniques PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (119 download)

DOWNLOAD NOW!


Book Synopsis Accuracy of Various Intraoral Digital Impression Techniques by : Archontia Emmanouilidi

Download or read book Accuracy of Various Intraoral Digital Impression Techniques written by Archontia Emmanouilidi and published by . This book was released on 2020* with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Full Arch Accuracy of Intraoral Scanners

Download Full Arch Accuracy of Intraoral Scanners PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 30 pages
Book Rating : 4.:/5 (1 download)

DOWNLOAD NOW!


Book Synopsis Full Arch Accuracy of Intraoral Scanners by : Joshua C. Treesh

Download or read book Full Arch Accuracy of Intraoral Scanners written by Joshua C. Treesh and published by . This book was released on 2017 with total page 30 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Reproducibility and Validity of Tooth Measurements Made from a 3D Digital Model Scanner Compared to Plaster Molds

Download Reproducibility and Validity of Tooth Measurements Made from a 3D Digital Model Scanner Compared to Plaster Molds PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 90 pages
Book Rating : 4.:/5 (855 download)

DOWNLOAD NOW!


Book Synopsis Reproducibility and Validity of Tooth Measurements Made from a 3D Digital Model Scanner Compared to Plaster Molds by : Scott Cardall

Download or read book Reproducibility and Validity of Tooth Measurements Made from a 3D Digital Model Scanner Compared to Plaster Molds written by Scott Cardall and published by . This book was released on 2012 with total page 90 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Accuracy of Four Recent Intraoral Scanners with Respect to Two Different Ceramic Surfaces

Download Accuracy of Four Recent Intraoral Scanners with Respect to Two Different Ceramic Surfaces PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (143 download)

DOWNLOAD NOW!


Book Synopsis Accuracy of Four Recent Intraoral Scanners with Respect to Two Different Ceramic Surfaces by : Berfin Bahar Yatmaz

Download or read book Accuracy of Four Recent Intraoral Scanners with Respect to Two Different Ceramic Surfaces written by Berfin Bahar Yatmaz and published by . This book was released on 2023 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

LoT Driven Dental Intraoral Scanner for Generating 3D Models and Digital Impressions

Download LoT Driven Dental Intraoral Scanner for Generating 3D Models and Digital Impressions PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (136 download)

DOWNLOAD NOW!


Book Synopsis LoT Driven Dental Intraoral Scanner for Generating 3D Models and Digital Impressions by :

Download or read book LoT Driven Dental Intraoral Scanner for Generating 3D Models and Digital Impressions written by and published by . This book was released on 2023 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: