ANALYSE DES SOLIDES PAR COUPLAGE DE L'ABLATION LASER ET DE LA SPECTROMETRIE DE MASSE A SOURCE PLASMA (LA-ICPMS) EN ENCEINTE CONFINEE

Download ANALYSE DES SOLIDES PAR COUPLAGE DE L'ABLATION LASER ET DE LA SPECTROMETRIE DE MASSE A SOURCE PLASMA (LA-ICPMS) EN ENCEINTE CONFINEE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 223 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis ANALYSE DES SOLIDES PAR COUPLAGE DE L'ABLATION LASER ET DE LA SPECTROMETRIE DE MASSE A SOURCE PLASMA (LA-ICPMS) EN ENCEINTE CONFINEE by : CHRISTOPHE.. LELOUP

Download or read book ANALYSE DES SOLIDES PAR COUPLAGE DE L'ABLATION LASER ET DE LA SPECTROMETRIE DE MASSE A SOURCE PLASMA (LA-ICPMS) EN ENCEINTE CONFINEE written by CHRISTOPHE.. LELOUP and published by . This book was released on 1998 with total page 223 pages. Available in PDF, EPUB and Kindle. Book excerpt: DANS L'INDUSTRIE NUCLEAIRE, L'ANALYSE D'ELEMENTS D'ALLIAGES OU D'IMPURETES DANS LES SOLIDES SE FAIT A L'AIDE DES TECHNIQUES A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE (ICP), COUPLEES A LA SPECTROMETRIE D'EMISSION ATOMIQUE (ICP-AES), OU A LA SPECTROMETRIE DE MASSE (ICP-MS). HABITUELLEMENT, CES TECHNIQUES NECESSITENT L'INTRODUCTION DE L'ECHANTILLON SOUS FORME D'AEROSOL, PAR NEBULISATION D'UN LIQUIDE. OUTRE LES DIFFICULTES LIEES A LA MISE EN SOLUTION DES SOLIDES (PERTE D'ELEMENTS VOLATILS, CREATION D'INSOLUBLES...), CETTE METHODE PRODUIT DES EFFLUENTS. LE REMPLACEMENT DE LA NEBULISATION D'ECHANTILLONS LIQUIDES PAR UN SYSTEME QUI FAIT APPEL A LA GENERATION D'AEROSOL PAR ABLATION LASER, CAPABLE DE TRAVAILLER DIRECTEMENT SUR LE SOLIDE, DOIT PERMETTRE DE PALLIER A CES INCONVENIENTS. LA MISE EN PLACE D'UN COUPLAGE DE L'ABLATION LASER ET DE LA SPECTROMETRIE DE MASSE A SOURCE PLASMA (LA-ICPMS) EN ENCEINTE CONFINEE (BOITE A GANTS), ET SA MISE AU POINT POUR L'ANALYSE ELEMENTAIRE QUANTITATIVE PRECISE DES SOLIDES, CONSTITUE L'OBJECTIF DE CE TRAVAIL. LES REGLAGES DU SPECTROMETRE ONT ETE ETUDIES DE FACON A AUGMENTER LA SENSIBILITE ET LA STABILITE. LA MISE EN PLACE D'UN FILTRE SPATIAL DU FAISCEAU DU LASER A EXCIMERES (XECL, =308 NM) A PERMIS UN GAIN SUBSTANTIEL DES PERFORMANCES ANALYTIQUES. L'ETUDE DE L'AEROSOL (COMPOSITION EN FONCTION DE LA GRANULOMETRIE) A CONTRIBUE A LA COMPREHENSION DES PHENOMENES D'ABLATION LASER MIS EN JEU. LES LIMITES DE DETECTION DE CERTAINS ELEMENTS ONT PU ETRE DIMINUEES EN MAITRISANT L'ATMOSPHERE DE LA BOITE A GANTS. LE POTENTIEL ANALYTIQUE DU COUPLAGE LA-ICPMS A ETE EVALUE PAR LE DOSAGE D'ELEMENTS MINEURS DANS LES ACIERS, ET DE TRACES DANS L'URANIUM. LES LIMITES DE DETECTION DE LA TECHNIQUE SONT DE QUELQUES DIZAINES DE NANOGRAMMES PAR GRAMME (PPB). ELLE PERMET UN GAIN EN TEMPS D'ANALYSE D'UN FACTEUR 2 A 3 AINSI QU'UNE DIMINUTION, VOIRE SUPPRESSION DES EFFLUENTS.

Analysis of Solids by Laser Ablation Inductively Coupled Plasma Mass Spectrometry

Download Analysis of Solids by Laser Ablation Inductively Coupled Plasma Mass Spectrometry PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 188 pages
Book Rating : 4.:/5 (544 download)

DOWNLOAD NOW!


Book Synopsis Analysis of Solids by Laser Ablation Inductively Coupled Plasma Mass Spectrometry by : David Brian Aeschliman

Download or read book Analysis of Solids by Laser Ablation Inductively Coupled Plasma Mass Spectrometry written by David Brian Aeschliman and published by . This book was released on 2003 with total page 188 pages. Available in PDF, EPUB and Kindle. Book excerpt: This dissertation manuscript concentrates on methods to improve the utility of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) as a rapid and accurate technique for quantitative analysis, forensic matching, and source attribution of solid samples. A solution calibration method for LA-ICP-MS is described that does not require matrix-matched solid standards or prior knowledge of sample composition. Desolvated particles from a microconcentric nebulizer and particles ablated from a localized position on a solid sample are mixed and introduced simultaneously to the ICP-MS. The transport of sample particulates from the ablation cell is measured online with piezoelectric microbalance to provide signal normalization. The relative accuracy of the quantitative analysis of NIST 612 glass and NIST 1264a steel is 3% and 12%, respectively, except for the elements Pb and Bi in steel. LA-ICP-MS is also used with principal components analysis (PCA) to simplify routine comparisons of forensic materials without time-consuming and destructive sample dissolution. The relative concentrations of trace elements in a solid sample are examined to provide a "fingerprint" composition that can be used for definitive identification and source matching of the material. Residue samples are matched to bulk materials using PCA. Variation of laser focus and PCA are also used to diagnose the presence and severity of elemental fractionation, which remains the most significant limitation for accurate quantitative analyses by LA-ICP-MS. High-speed photographs and video of an ICP are used to examine the validity of solution calibration for LA-ICP-MS and to study the trajectories, lifetimes, and emission behavior of particles traversing the plasma under a variety of conditions. No red emission clouds from YO are visible in the ICP when a 20-[mu]L min−1 nebulizer is used to spray a 2000 ppm aqueous yttrium solution, suggesting that the wet droplets from this nebulizer desolvate almost completely before entering the ICP. These desolvated particles appear to atomize and ionize like the small dry particulates from laser ablation. However, some large ablated particulates are observed to fly through the plasma intact, possibly contributing to elemental fractionation. Nevertheless, accurate calibration results using solution standards can be obtained for elements not affected by fractionation.

ETUDE ET DEVELOPPEMENT DU COUPLAGE ABLATION LASER - SPECTROMETRIE PLASMA (ICP) POUR L'ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DANS LES MATIERES PLASTIQUES

Download ETUDE ET DEVELOPPEMENT DU COUPLAGE ABLATION LASER - SPECTROMETRIE PLASMA (ICP) POUR L'ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DANS LES MATIERES PLASTIQUES PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 262 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis ETUDE ET DEVELOPPEMENT DU COUPLAGE ABLATION LASER - SPECTROMETRIE PLASMA (ICP) POUR L'ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DANS LES MATIERES PLASTIQUES by : MICHEL.. HEMMERLIN

Download or read book ETUDE ET DEVELOPPEMENT DU COUPLAGE ABLATION LASER - SPECTROMETRIE PLASMA (ICP) POUR L'ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DANS LES MATIERES PLASTIQUES written by MICHEL.. HEMMERLIN and published by . This book was released on 1997 with total page 262 pages. Available in PDF, EPUB and Kindle. Book excerpt: LES SPECTROMETRIES D'EMISSION ATOMIQUE ET DE MASSE ELEMENTAIRE UTILISANT UN PLASMA A COUPLAGE INDUCTIF (ICP-AES ET ICP-MS) SONT DESORMAIS DES TECHNIQUES BIEN ETABLIES POUR L'ANALYSE MULTIELEMENTAIRE DE TRACES DANS DIVERSES MATRICES NATURELLES OU SYNTHETIQUES. GENERALEMENT, L'INTRODUCTION DE L'ECHANTILLON DANS LE PLASMA SE FAIT PAR NEBULISATION PNEUMATIQUE D'UNE SOLUTION ISSUE D'UN TRAITEMENT CHIMIQUE (ATTAQUE) D'UNE MATRICE SOLIDE. CETTE ETAPE DE MISE EN SOLUTION PRESENTE DE NOMBREUSES LIMITATIONS ET EST RENDUE DE PLUS EN PLUS DIFFICILE PAR LA SOLUBILITE RESTREINTE ET LA RESISTANCE CHIMIQUE ELEVEE DE CERTAINS POLYMERES. L'ABLATION LASER, TERME QUI DECRIT LA DESTRUCTION PROGRESSIVE ET SUPERFICIELLE D'UNE CIBLE SOLIDE, EST UNE TECHNIQUE D'INTRODUCTION DE L'ECHANTILLON TRES ATTRACTIVE. OUTRE L'ELIMINATION DE TOUTE PREPARATION CHIMIQUE, ET DONC LE GAIN EN TEMPS D'ANALYSE QU'ELLE OFFRE, CETTE METHODE D'ECHANTILLONNAGE DISPOSE D'UNE RESOLUTION SPATIALE DONNANT ACCES A DES INFORMATIONS NOUVELLES QUANT A LA REPARTITION DES ELEMENTS DANS UNE MATRICE. CEPENDANT, LES PARAMETRES REGISSANT L'INTERACTION LASER-MATIERE SONT ENCORE MAL MAITRISES, ET LES ETUDES CONCERNANT L'ANALYSE DES MATIERES PLASTIQUES PAR ABLATION LASER-PLASMA ICP SONT QUASIMENT INEXISTANTES. L'OBJECTIF DE CE TRAVAIL RESIDE DANS LE DEVELOPPEMENT ET L'EVALUATION ANALYTIQUE DE CE COUPLAGE POUR L'ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DES MATIERES PLASTIQUES. LES PERFORMANCES DE L'ETAPE D'ECHANTILLONNAGE, DONT L'ELEMENT FONDAMENTAL EST LE FAISCEAU LASER ET SES PROPRIETES, ONT ETE ETUDIEES AFIN D'APPROFONDIR NOS CONNAISSANCES DU MECANISME D'INTERACTION LASER-POLYMERE. L'INFLUENCE DE PARAMETRES TELS QUE LA LONGUEUR D'ONDE, L'ENERGIE D'IRRADIATION OU LA FOCALISATION DU FAISCEAU LASER A ETE EVALUEE. LES CONTRIBUTIONS DES EFFETS DE SEUIL D'ABLATION DES POLYMERES ET DES EFFETS D'ECRAN CREES PAR LE MICROPLASMA INDUIT PAR LASER SONT DISCUTEES. L'ETUDE DE L'INFLUENCE DES PROPRIETES DES ECHANTILLONS A REVELE L'IMPORTANCE DE PARAMETRES NOUVEAUX TELS QUE LA STRUCTURE CHIMIQUE DES ADDITIFS DES POLYMERES, OU LES INTERACTIONS ENTRE ADDITIFS ET POLYMERES. L'EVALUATION ANALYTIQUE DU COUPLAGE A MIS EN EXERGUE D'EXCELLENTES PERFORMANCES EN TERMES DE REPRODUCTIBILITE (2-5%), DE LINEARITE DE L'ETALONNAGE, ET DE LIMITES DE DETECTION (INFERIEURES A LA PPB). CES RESULTATS PLACENT CETTE TECHNIQUE A UN RANG DE PERFORMANCE AU MOINS EQUIVALENT A CELUI DE LA FLUORESCENCE X OU DE L'ACTIVATION NEUTRONIQUE POUR L'ANALYSE DES SOLIDES.

ETUDE DE L'ABLATION LASER COMME SYSTEME D'INTRODUCTION D'UN SPECTROMETRE D'EMISSION PLASMA INDUIT PAR HAUTE FREQUENCE POUR L'ANALYSE DES VERRES

Download ETUDE DE L'ABLATION LASER COMME SYSTEME D'INTRODUCTION D'UN SPECTROMETRE D'EMISSION PLASMA INDUIT PAR HAUTE FREQUENCE POUR L'ANALYSE DES VERRES PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 221 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis ETUDE DE L'ABLATION LASER COMME SYSTEME D'INTRODUCTION D'UN SPECTROMETRE D'EMISSION PLASMA INDUIT PAR HAUTE FREQUENCE POUR L'ANALYSE DES VERRES by : MURIELLE.. DUCREUX

Download or read book ETUDE DE L'ABLATION LASER COMME SYSTEME D'INTRODUCTION D'UN SPECTROMETRE D'EMISSION PLASMA INDUIT PAR HAUTE FREQUENCE POUR L'ANALYSE DES VERRES written by MURIELLE.. DUCREUX and published by . This book was released on 1994 with total page 221 pages. Available in PDF, EPUB and Kindle. Book excerpt: ACTUELLEMENT, L'ANALYSE ELEMENTAIRE DE NOMBREUX TYPES DE MATERIAUX EST EFFECTUEE PAR DES METHODES NECESSITANT UNE PREPARATION FASTIDIEUSE DES ECHANTILLONS (SPECTROMETRIE D'ABSORPTION ET D'EMISSION ATOMIQUE, FLUORESCENCE X, SPECTROMETRIE D'ARC), QUI PEUVENT INDUIRE DES CONTAMINATIONS OU DES PERTES. AUSSI, EXISTE-T-IL UNE FORTE DEMANDE POUR L'ANALYSE DIRECTE DE SOLIDES. PARMI LES DIVERSES METHODES ETUDIEES (DECHARGE LUMINESCENTE, SPECTROMETRIE ETINCELLE), LE COUPLAGE ABLATION LASER SPECTROMETRIE D'EMISSION ATOMIQUE ICP CONNAIT UN DEVELOPPEMENT CROISSANT. CETTE TECHNIQUE PRESENTE EN EFFET DES AVANTAGES CERTAINS: ANALYSE DE TOUT TYPE DE MATERIAU, CONDUCTEUR OU ISOLANT, CELLE-CI POUVANT ETRE GLOBALE OU PONCTUELLE DUE A LA POSSIBILITE DE FOCALISER LE FAISCEAU LASER A UN ENDROIT PRECIS DE LA CIBLE (EXCELLENTE RESOLUTION SPATIALE). LE PRINCIPE DE LA METHODE CONSISTE A UTILISER LE MECANISME D'ABLATION COMME SOURCE DE FINES PARTICULES QUI SONT TRANSPORTEES PAR UN COURANT D'ARGON DANS UN PLASMA DE TYPE ICP POUR ETRE ATOMISEES, EXCITEES ET IONISEES. LE FAISCEAU POLYCRHOMATIQUE RESULTANT EST DISPERSE PAR UN RESEAU EN RADIATIONS MONOCHROMATIQUES, QUI SONT ALORS DETECTEES PAR DIFFERENTS SYSTEMES RECEPTIFS: PHOTOMULTIPLICATEURS, DETECTEURS DE TYPE CCD L'EVALUATION DE LA TECHNIQUE POUR L'ANALYSE QUANTITATIVE DES VERRES CONSTITUE L'OBJECTIF DE CE TRAVAIL. COMPTE-TENU DE LA TRANSPARENCE DE CES MATERIAUX DANS LES DOMAINES DU VISIBLE ET DU PROCHE INFRAROUGE, DES LASERS EMETTANT DANS L'ULTRAVIOLET ONT DUS ETRE UTILISES: UN LASER EXCIMERE DE TYPE XECL ET UN LASER ND:YAG TRIPLE ET QUADRUPLE EN FREQUENCE EMETTANT RESPECTIVEMENT A 308, 355 ET 266 NM. L'ETUDE DE L'INTERACTION LASER-MATIERE (QUANTITES DE MATIERE ABLATEES, FORMES ET DIMENSIONS DES CRATERES,) A PERMIS DE COMPARER CES DIFFERENTES SOURCES D'INTRODUCTION D'ECHANTILLON DANS LE PLASMA, ET D'EXPLIQUER LES DIFFERENCES DE PERFORMANCES ANALYTIQUES (REPETABILITE, REPRODUCTIBILITE, JUSTESSE, LIMITES DE DETECTION) OBTENUES POUR CHACUNE. LE DOMAINE D'APPLICATION DE LA METHODE A PU EGALEMENT ETRE ETENDU GRACE A DES ETUDES PRELIMINAIRES CONCERNANT L'ANALYSE DE SURFACES DE FAIBLES EPAISSEURS, L'ANALYSE SEMI-QUANTITATIVE DE VERRES ET DE MATIERES PREMIERES, L'ANALYSE QUALITATIVE DE DEFAUTS

ETUDE ET CARACTERISATION DU COUPLAGE ABLATION LASER-PLASMA H.F. (I.C.P.)

Download ETUDE ET CARACTERISATION DU COUPLAGE ABLATION LASER-PLASMA H.F. (I.C.P.) PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis ETUDE ET CARACTERISATION DU COUPLAGE ABLATION LASER-PLASMA H.F. (I.C.P.) by : Frédéric Chartier

Download or read book ETUDE ET CARACTERISATION DU COUPLAGE ABLATION LASER-PLASMA H.F. (I.C.P.) written by Frédéric Chartier and published by . This book was released on 1991 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ANALYSE DIRECTE D'ELEMENTS DANS LES SOLIDES, EVITANT LA MISE EN SOLUTION, EST UNE NECESSITE EN SPECTROMETRIE D'EMISSION ATOMIQUE (AES). L'ABLATION LASER PERMET LA PRODUCTION DE PARTICULES QUI PEUVENT ETRE ATOMISEES, EXCITEES ET IONISEES DANS UNE SOURCE SECONDAIRE TELLE QU'UN PLASMA INDUIT PAR HAUTE FREQUENCE (I.C.P.). LE COUPLAGE ABLATION LASER/I.C.P. CONSTITUE LE THEME DE NOTRE ETUDE. L'IMPORTANCE DES CARACTERISTIQUES DU LASER TELLES QUE LE MODE DE FONCTIONNEMENT, LA DUREE DE L'IMPULSION, LA FORME DU FAISCEAU ET LA LONGUEUR D'ONDE EST MISE EN EVIDENCE. LES PERFORMANCES DE L'ENSEMBLE PORTE-EBULLITION/CELLULE D'ABLATION ET LE RENDEMENT DE TRANSPORT SONT EVALUES. LA SELECTION D'UN LASER ADAPTE AUX NECESSITES DE L'ABLATION EST EFFECTUEE PAR L'INTERMEDIAIRE D'UNE ETUDE COMPARATIVE DE DIFFERENTS LASERS ET DE LEURS PARAMETRES (TAUX DE REPETITION, ENERGIE), SUR: L'EFFICACITE D'ABLATION, LA TAILLE ET LA QUANTITE DES AEROSOLS PRODUITS, LES PERFORMANCES ANALYTIQUES EN I.C.P./A.E.S. DIFFERENTES NATURES D'ECHANTILLONS SONT TESTEES: METAUX, VERRES... LES RESULTATS MONTRENT QUE LE LASER A EXCIMERES EST PLUS ADAPTE AU COUPLAGE ABLATION LASER/I.C.P. PAR RAPPORT AU LASER ND:YAG

Calibration of Laser Ablation Inductively Coupled Plasma Mass Spectrometry Using Dried Solution Aerosols for the Quantitative Analysis of Solids

Download Calibration of Laser Ablation Inductively Coupled Plasma Mass Spectrometry Using Dried Solution Aerosols for the Quantitative Analysis of Solids PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 90 pages
Book Rating : 4.:/5 (396 download)

DOWNLOAD NOW!


Book Synopsis Calibration of Laser Ablation Inductively Coupled Plasma Mass Spectrometry Using Dried Solution Aerosols for the Quantitative Analysis of Solids by : James Joseph Leach

Download or read book Calibration of Laser Ablation Inductively Coupled Plasma Mass Spectrometry Using Dried Solution Aerosols for the Quantitative Analysis of Solids written by James Joseph Leach and published by . This book was released on 1998 with total page 90 pages. Available in PDF, EPUB and Kindle. Book excerpt: This thesis concerns itself with the use of inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of solid samples. The instrumentation and attributes of ICP-MS are presented. The theoretical and practical considerations of laser ablation as a solid sampling source are reviewed. The feasibility of quantitative analysis of solids by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is assessed. A formula is presented which illustrates that solution standards can be used for the calibration of solids.

DEVELOPPEMENT ET EVALUATION DU COUPLAGE ABLATION LASER-SPECTROMETRIE D'EMISSION PLASMA (ICP) POUR L'ANALYSE DES METAUX ET ALLIAGES

Download DEVELOPPEMENT ET EVALUATION DU COUPLAGE ABLATION LASER-SPECTROMETRIE D'EMISSION PLASMA (ICP) POUR L'ANALYSE DES METAUX ET ALLIAGES PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 189 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis DEVELOPPEMENT ET EVALUATION DU COUPLAGE ABLATION LASER-SPECTROMETRIE D'EMISSION PLASMA (ICP) POUR L'ANALYSE DES METAUX ET ALLIAGES by : MATHIAS.. GAGEAN

Download or read book DEVELOPPEMENT ET EVALUATION DU COUPLAGE ABLATION LASER-SPECTROMETRIE D'EMISSION PLASMA (ICP) POUR L'ANALYSE DES METAUX ET ALLIAGES written by MATHIAS.. GAGEAN and published by . This book was released on 1996 with total page 189 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ICP EST MAINTENANT ETABLI COMME LA TECHNIQUE ANALYTIQUE DE BASE POUR L'ANALYSE MULTIELEMENTAIRE DES IMPURETES ET DES ELEMENTS TRACES DES ECHANTILLONS LIQUIDES. CEPENDANT LA NEBULISATION DE L'ECHANTILLON A DE NOMBREUSES LIMITATIONS POUR L'ANALYSE DES ALLIAGES METALLIQUES. L'INTRODUCTION DIRECTE DE L'ECHANTILLON SOUS FORME SOLIDE POUR L'ANALYSE PAR ICP SEMBLE UNE METHODE INTERESSANTE CAR ELLE EVITE L'ETAPE DE DISSOLUTION. L'ABLATION LASER SEMBLE OFFRIR, A PRIORI, DE GRANDES POSSIBILITES POUR L'ANALYSE D'ECHANTILLONS SOLIDES QUELLE QUE SOIT LEUR NATURE, CONDUCTEURS OU NON-CONDUCTEURS. L'OBJECTIF DE CE TRAVAIL EST DONC DE DEVELOPPER ET D'EVALUER LE COUPLAGE ABLATION LASER ICP-AES DANS LE DOMAINE DES ALLIAGES METALLIQUES ET PLUS PARTICULIEREMENT SUR LES LAITONS. LES PERFORMANCES DU COUPLAGE ABLATION LASER ICP-AES SONT EVALUEES PAR LE BIAIS DES LIMITES DE DETECTION. LES PERFORMANCES DE L'ABLATION LASER SONT COMPAREES A UNE TECHNIQUE ANALYTIQUE SPECIFIQUE AUX MATERIAUX CONDUCTEURS: L'ABLATION ETINCELLE. LE TYPE D'APPAREILLAGE ET LES CONDITIONS ANALYTIQUES OPTIMALES POUR OBTENIR DES LIMITES DE DETECTION POUVANT CONCURRENCER LE COUPLAGE ABLATION LASER ICP-MS SONT DECRITES. LE COMPORTEMENT DU ZINC ET DU CUIVRE DANS UNE MATRICE DE LAITON EN FONCTION DE LEUR CONCENTRATION EST ETUDIE. UN COMPORTEMENT ANORMAL EST MIS EN EVIDENCE ET L'ORIGINE DE CETTE ANOMALIE EST LOCALISEE. L'INFLUENCE DES PARAMETRES EXPERIMENTAUX EST AUSSI DETERMINEE. ENFIN, UNE ETUDE DE FAISABILITE EST EFFECTUEE DANS UN DES DOMAINES D'APPLICATION SPECIFIQUE A L'ABLATION LASER QUI EST L'ANALYSE DE PROFILS DE CONCENTRATION EN PROFONDEUR PAR L'INTERMEDIAIRE DE DEUX CAS CONCRETS

ETUDE DE L'ABLATION LASER POUR L'ANALYSE ELEMENTAIRE DANS LES SOLIDES. ETUDE DES FACTEURS GOUVERNANT LE PHENOMENE D'ABLATION. APPLICAITON A L'ANALYSE EN ENCEINTE CONFINEE

Download ETUDE DE L'ABLATION LASER POUR L'ANALYSE ELEMENTAIRE DANS LES SOLIDES. ETUDE DES FACTEURS GOUVERNANT LE PHENOMENE D'ABLATION. APPLICAITON A L'ANALYSE EN ENCEINTE CONFINEE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 287 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis ETUDE DE L'ABLATION LASER POUR L'ANALYSE ELEMENTAIRE DANS LES SOLIDES. ETUDE DES FACTEURS GOUVERNANT LE PHENOMENE D'ABLATION. APPLICAITON A L'ANALYSE EN ENCEINTE CONFINEE by : SYLVIE.. MASSEAU

Download or read book ETUDE DE L'ABLATION LASER POUR L'ANALYSE ELEMENTAIRE DANS LES SOLIDES. ETUDE DES FACTEURS GOUVERNANT LE PHENOMENE D'ABLATION. APPLICAITON A L'ANALYSE EN ENCEINTE CONFINEE written by SYLVIE.. MASSEAU and published by . This book was released on 1993 with total page 287 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ANALYSE DIRECTE D'ELEMENTS DANS LES SOLIDES PAR SPECTROMETRIE D'EMISSION ATOMIQUE TORCHE A PLASMA EST D'AUTANT PLUS NECESSAIRE POUR LES ECHANTILLONS RADIOACTIFS ET TOXIQUES QUE LA MISE EN SOLUTION EST LONGUE ET GENERE DES DECHETS RADIOACTIFS. ELLE PEUT ETRE REALISEE AU MOYEN DE L'ABLATION LASER. CETTE ETUDE COMPREND DEUX PARTIES: 1) LA REALISATION D'UN SYSTEME D'ABLATION LASER COUPLE A UNE TORCHE A PLASMA EN ENCEINTE CONFINEE. LE CHOIX DU LASER S'EST PORTE VERS UN LASER A EXCIMERES XECL. UNE CELLULE D'ABLATION, SIMPLE A UTILISER EN BOITE A GANTS ET PRESENTANT UN RENDEMENT DE TRANSPORT ELEVE, A ETE DEVELOPPEE; 2) L'EVALUATION DES PERFORMANCES ANALYTIQUES DE LA METHODE SUR LES MATRICES BERYLLIUM, PLUTONIUM ET URANIUM

Optimisation des conditions d'échantillonnage par ablation laser, pour l'analyse directe de solides par spectrométrie de masse à couplage plasma induit . Application au dosage du bore et de l'hafnium

Download Optimisation des conditions d'échantillonnage par ablation laser, pour l'analyse directe de solides par spectrométrie de masse à couplage plasma induit . Application au dosage du bore et de l'hafnium PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 134 pages
Book Rating : 4.:/5 (494 download)

DOWNLOAD NOW!


Book Synopsis Optimisation des conditions d'échantillonnage par ablation laser, pour l'analyse directe de solides par spectrométrie de masse à couplage plasma induit . Application au dosage du bore et de l'hafnium by : Jean-Luc DAUTHERIBES

Download or read book Optimisation des conditions d'échantillonnage par ablation laser, pour l'analyse directe de solides par spectrométrie de masse à couplage plasma induit . Application au dosage du bore et de l'hafnium written by Jean-Luc DAUTHERIBES and published by . This book was released on 1993 with total page 134 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Étude expérimentale et modélisation des potentialités de la technique libs (ablation laser couplée à la spectroscopie) pour l'analyse directe des solides

Download Étude expérimentale et modélisation des potentialités de la technique libs (ablation laser couplée à la spectroscopie) pour l'analyse directe des solides PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 0 pages
Book Rating : 4.:/5 (863 download)

DOWNLOAD NOW!


Book Synopsis Étude expérimentale et modélisation des potentialités de la technique libs (ablation laser couplée à la spectroscopie) pour l'analyse directe des solides by : Flory-Anne Barreda

Download or read book Étude expérimentale et modélisation des potentialités de la technique libs (ablation laser couplée à la spectroscopie) pour l'analyse directe des solides written by Flory-Anne Barreda and published by . This book was released on 2010 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'utilisation de lasers est largement répandue dans le domaine de la microanalyse directe des solides. La matière vaporisée, en focalisant un faisceau laser de forte puissance sur la cible, peut être analysée soit par spectrométrie d'émission optique sur plasma induit (LIBS, acronyme anglais pour Laser Induced Breakdown Spectroscopy), soit par une source à plasma induit par haute fréquence couplée à la spectrométrie d'émission optique (ICP-AES) ou à la spectrométrie de masse (ICP-MS). Avec une résolution spatiale à l'échelle microscopique, les techniques d'ablation laser permettent ainsi d'accéder à la composition élémentaire locale de la surface d'un matériau. Néanmoins, les performances analytiques de ces techniques pourraient être améliorées par l'utilisation combinée des informations LIBS et ICP afin également de comprendre et maîtriser davantage l'interaction laser/matière. Dans ce but, ce travail a consisté à développer une technique de microanalyse par ablation laser couplée avec une détection en simultané par ICP et par LIBS afin d'étudier les potentialités analytiques de cet instrument pour cartographier la surface des matériaux. Les performances et les limitations de ce système ont été évaluées d'une part, en caractérisant les aérosols produits par ablation laser et d'autre part, en étudiant les signaux LIBS et ICP obtenus à partir d'un même prélèvement de matière. Le phénomène de fractionnement élémentaire rencontré sur des matrices critiques telles que le laiton a été mis en évidence en microablation malgré des caractéristiques de l'interaction laser/matière différente de la macroablation. Une méthode de correction, a posteriori, par l'efficacité d'extraction de la cellule d'ablation a été proposée afin de pallier ces effets limitatifs pour l'analyse quantitative. Une cellule d'ablation, optimisée à partir d'une étude de simulation numérique, a été développée afin de s'adapter aux applications de cartographies de surface. Les performances analytiques du système ont été évaluées en termes de stabilité (8-10%), de résolution spatiale (5 μm) et de limites de détection (de l'ordre de la ppm dans le solide avec un détecteur de masse). La complémentarité des mesures LIBS et ICP représente à la fois un outil de diagnostic de l'interaction laser/matière et un instrument d'analyse très complet grâce à la double détection qui permet de suivre simultanément des traces et des majeurs sur une large gamme d'éléments de la classification périodique.

Développement et applications d’un système laser femtoseconde infra-rouge basse énergie et haute cadence de tir pour l’analyse d’éléments trace dans les solides par couplage ablation laser

Download Développement et applications d’un système laser femtoseconde infra-rouge basse énergie et haute cadence de tir pour l’analyse d’éléments trace dans les solides par couplage ablation laser PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 294 pages
Book Rating : 4.:/5 (494 download)

DOWNLOAD NOW!


Book Synopsis Développement et applications d’un système laser femtoseconde infra-rouge basse énergie et haute cadence de tir pour l’analyse d’éléments trace dans les solides par couplage ablation laser by : Fanny Claverie

Download or read book Développement et applications d’un système laser femtoseconde infra-rouge basse énergie et haute cadence de tir pour l’analyse d’éléments trace dans les solides par couplage ablation laser written by Fanny Claverie and published by . This book was released on 2009 with total page 294 pages. Available in PDF, EPUB and Kindle. Book excerpt: L’ablation laser couplée à une détection par spectrométrie de masse à plasma induit apparait de plus en plus comme un outil de choix pour l’analyse des solides. L’utilisation de sources laser femtoseconde permet d’améliorer les performances analytiques du couplage, l’interaction laser-matière privilégiant les phénomènes athermiques contrairement aux lasers nanoseconde plus classiquement utilisés. Une collaboration entre le Laboratoire de Chimie Analytique Bio-Inorganique et Environnement de Pau et Novalase SA (spécialisé dans l’intégration optique et laser) a fait naitre la première station d’ablation laser femtoseconde intégrée. Ses caractéristiques particulières, que sont la haute cadence de tir et un optique de balayage rapide du faisceau, permettent d’explorer de nouvelles stratégies d’ablation et ouvrent des perspectives analytiques encourageantes en terme de sensibilité et de mode de quantification. Le potentiel de ce prototype a été évalué au travers d’analyses fondamentales, telles que le fractionnement élémentaire et l’étude de la taille des particules de l’aérosol produit par ablation, et de différentes applications telles que l’analyse de sols et de sédiments par dilution isotopique réalisée par le laser dans la chambre d’ablation, la détection de sélénoprotéines dans des gels d’électrophorèse et la détermination de l’isotopie de l’uranium dans des particules micrométriques.

Conception et développement d'un spectromètre de masse à temps de vol couplé à une ionisation multiphotonique résonante

Download Conception et développement d'un spectromètre de masse à temps de vol couplé à une ionisation multiphotonique résonante PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 378 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis Conception et développement d'un spectromètre de masse à temps de vol couplé à une ionisation multiphotonique résonante by : Jean-Yves Gadat

Download or read book Conception et développement d'un spectromètre de masse à temps de vol couplé à une ionisation multiphotonique résonante written by Jean-Yves Gadat and published by . This book was released on 1999 with total page 378 pages. Available in PDF, EPUB and Kindle. Book excerpt: La microanalyse de solides présente un intérêt croissant pour l'étude de composés d'intérêt astrophysique (agrégats de carbone, glaces cométaires) ou atmosphérique (molécules piégées dans les glaces, aérosols). Ce travail a porté sur la conception et la réalisation d'un système de microanalyse de solides base sur le couplage de l'ablation laser (LA), de la photoionisation résonante (REMPI) et de la spectrométrie de masse à temps de vol (TOF). Le principe de fonctionnement du dispositif, ses principales caractéristiques et ses performances sont présentés. Compte tenu du caractère émergent de ces recherches dans le laboratoire, les techniques nécessaires à la microanalyse (REMPI, LA) ont du être validées séparément. La technique REMPI a été testée sur le radical CH3 produit dans une flamme de méthane stabilisée sur un brûleur. Plusieurs profils de concentration obtenus dans différentes conditions de flammes ont été réalisés. La comparaison avec les techniques habituellement utilisées (impact électronique, spectromètre quadripolaire) a permis de démontrer la meilleure sensibilité de la détection REMPI/TOF et de la valider comme méthode d'analyse d'espèces minoritaires. L'échantillonnage par la sous vide a été mis en place sur le spectromètre et testé dans différentes configurations. Si la détection des ions produits lors du processus d'ablation s'est montrée insuffisante, l'ionisation non résonante des espèces neutres éjectées durant l'ablation s'est avérée nettement plus performante grâce aux grandes sensibilité et résolution qu'elle offre. Les premiers résultats expérimentaux portant sur les agrégats de carbone sont décrits. L'ensemble des techniques développées au cours de ce travail sont maintenant opérationnelles ce qui rend possible leur association en vue de l'objectif initial : la microanalyse de solides. La récente acquisition d'un laser à colorant permettra d'étendre les études en cours à l'analyse de processus hétérogènes de surface (aérosols carbones, glaces).

SPECTROMETRIE DE MASSE PAR IONISATION LASER RESONNANTE

Download SPECTROMETRIE DE MASSE PAR IONISATION LASER RESONNANTE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis SPECTROMETRIE DE MASSE PAR IONISATION LASER RESONNANTE by : OLIVIER.. GOBERT

Download or read book SPECTROMETRIE DE MASSE PAR IONISATION LASER RESONNANTE written by OLIVIER.. GOBERT and published by . This book was released on 1989 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: LA SPECTROMETRIE DE MASSE PAR IONISATION LASER DES ATOMES NEUTRES EJECTES PAR BOMBARDEMENT IONIQUE EST UNE METHODE PROMETTEUSE POUR L'ANALYSE CHIMIQUE DE MATERIAUX SOLIDES. LE SYSTEME EXPERIMENTAL UTILISE COMPREND UNE ENCEINTE SOUS ULTRA-VIDE, UN SPECTROMETRE DE MASSE QUADRUPOLAIRE ET UN SYSTEME DE DEUX LASERS A COLORANTS POMPES PAR UN LASER ND: YAG. CETTE INSTALLATION PERMET DE DETECTER SELECTIVEMENT LES ATOMES EJECTES DE LA SURFACE DE L'ECHANTILLON PAR BOMBARDEMENT IONIQUE EN UTILISANT LA POST IONISATION LASER RESONNANTE ET LA DETECTION CONSECUTIVE DES PHOTOIONS CREES

Plasma Source Mass Spectrometry

Download Plasma Source Mass Spectrometry PDF Online Free

Author :
Publisher : Royal Society of Chemistry
ISBN 13 : 0854046631
Total Pages : 368 pages
Book Rating : 4.8/5 (54 download)

DOWNLOAD NOW!


Book Synopsis Plasma Source Mass Spectrometry by : Royal Society of Chemistry (Great Britain)

Download or read book Plasma Source Mass Spectrometry written by Royal Society of Chemistry (Great Britain) and published by Royal Society of Chemistry. This book was released on 2005 with total page 368 pages. Available in PDF, EPUB and Kindle. Book excerpt: Atomic spectrometry has exciting new bio-analytical horizons open to it, principally through the developments in the capabilities of ICP-MS coupled with the inventiveness of experimentalists. This is reflected in the use of the technique for ion-, capillary electrophoresis-, liquid- and gas-chromatographic separation in biological applications, as reported in this book. Traditional (environmental, semiconductor, geological and clinical) applications are also well represented. In addition, recent and future developments in sample introduction devices, multicollector sector, reaction cells and collision cells instruments, as well as co-existence, divergence and potential convergence of atomic and biomolecular mass spectrometries are discussed. Reflecting the current state of practical ICP-MS and drawing together the latest developments in the field, Plasma Source Mass Spectrometry: Current Trends and Future Developments is ideal for university researchers and laboratory practitioners. It will be of interest to all those involved in the development and application of this technique.

Spectrometries Laser en Analyse et Caracterisation

Download Spectrometries Laser en Analyse et Caracterisation PDF Online Free

Author :
Publisher : Ed. Techniques Ingénieur
ISBN 13 :
Total Pages : 16 pages
Book Rating : 4./5 ( download)

DOWNLOAD NOW!


Book Synopsis Spectrometries Laser en Analyse et Caracterisation by :

Download or read book Spectrometries Laser en Analyse et Caracterisation written by and published by Ed. Techniques Ingénieur. This book was released on with total page 16 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Applications of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for the Analysis of Solids

Download Applications of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for the Analysis of Solids PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 318 pages
Book Rating : 4.:/5 (452 download)

DOWNLOAD NOW!


Book Synopsis Applications of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for the Analysis of Solids by : Melody Bi

Download or read book Applications of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for the Analysis of Solids written by Melody Bi and published by . This book was released on 2000 with total page 318 pages. Available in PDF, EPUB and Kindle. Book excerpt:

VALIDATION DU COUPLAGE PLASMA (ICP) - SPECTROMETRIE DE MASSE POUR L'ANALYSE INORGANIQUE (ELEMENTS TRACE) DE MATRICES ALIMENTAIRES D'ORIGINE ANIMALE

Download VALIDATION DU COUPLAGE PLASMA (ICP) - SPECTROMETRIE DE MASSE POUR L'ANALYSE INORGANIQUE (ELEMENTS TRACE) DE MATRICES ALIMENTAIRES D'ORIGINE ANIMALE PDF Online Free

Author :
Publisher :
ISBN 13 :
Total Pages : 290 pages
Book Rating : 4.:/5 (49 download)

DOWNLOAD NOW!


Book Synopsis VALIDATION DU COUPLAGE PLASMA (ICP) - SPECTROMETRIE DE MASSE POUR L'ANALYSE INORGANIQUE (ELEMENTS TRACE) DE MATRICES ALIMENTAIRES D'ORIGINE ANIMALE by : SYLVIE-ISABELLE.. EXCOFFIER

Download or read book VALIDATION DU COUPLAGE PLASMA (ICP) - SPECTROMETRIE DE MASSE POUR L'ANALYSE INORGANIQUE (ELEMENTS TRACE) DE MATRICES ALIMENTAIRES D'ORIGINE ANIMALE written by SYLVIE-ISABELLE.. EXCOFFIER and published by . This book was released on 1997 with total page 290 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'INTERET ACTUELLEMENT PORTE A L'ANALYSE INORGANIQUE DE MATRICES ALIMENTAIRES S'EXPLIQUE PAR LES PROPRIETES NUTRITIONNELLES ET/OU TOXIQUES DES ELEMENTS IMPLIQUES. MAIS LES METHODES D'ANALYSE CONVENTIONNELLES UTILISEES, PRINCIPALEMENT DIFFERENTES TECHNIQUES DE SPECTROMETRIE D'ABSORPTION ATOMIQUE, ONT COMME PRINCIPALE LIMITATION D'ETRE MONO-ELEMENTAIRES. LE COUPLAGE PLASMA - SPECTROMETRIE D'EMISSION ATOMIQUE (ICP-AES) PERMET L'ANALYSE MULTI-ELEMENTAIRE MAIS LES LIMITES DE DETECTION ALORS OBTENUES SONT TROP ELEVEES (DE L'ORDRE DU G/L) POUR CETTE APPLICATION. LE COUPLAGE PLASMA - SPECTROMETRIE DE MASSE, EN ASSOCIANT CAPACITE D'ANALYSE MULTI-ELEMENTAIRE ET FAIBLES LIMITES DE DETECTION (DE L'ORDRE DU NG/L), S'AVERE ETRE UN OUTIL EFFICACE DANS CE CHAMP D'APPLICATIONS SPECIFIQUE. TOUTEFOIS, CET AVANTAGE IMPOSE D'ETABLIR DES COMPROMIS DANS L'OPTIMISATION DE L'ICP-MS AFIN DE PERMETTRE LA DETERMINATION DU PLUS GRAND NOMBRE D'ELEMENTS DANS LES MEILLEURES CONDITIONS. LA PREMIERE ETAPE A ETE DE RECHERCHER SUR DES SOLUTIONS ETALONS UN COMPROMIS ACCEPTABLE POUR L'ENSEMBLE DES ANALYTES (AL, AS, CD, CO, CR, CU, FE, MN, MO, NI, PB, SB, SE, SN ET ZN), DISTRIBUES SUR LA TOTALITE DE LA GAMME DES MASSES (DE 27 A 208 UMA). NOUS AVONS ALORS ETUDIE, POUR DIFFERENTES OPTIMISATIONS, LEURS CARACTERISTIQUES ANALYTIQUES : LINEARITE, SENSIBILITE, REPETABILITE, DERIVE A LONG TERME ET SPECIFICITE DU SIGNAL ASSOCIE. MAIS LES ECHANTILLONS ANALYSES COURAMMENT AU LABORATOIRE DOIVENT SUBIR AU PREALABLE UNE ETAPE NECESSAIRE DE MINERALISATION, ET, A CE NIVEAU DE CONCENTRATION (PPB), LES CONTAMINATIONS SONT FREQUENTES. DANS UNE DEUXIEME ETAPE, NOUS AVONS DONC ETUDIE PAS A PAS LES SOURCES POSSIBLES DE CONTAMINATIONS : QUALITE DES REACTIFS, VAISSELLE UTILISEE... NOUS NOUS SOMMES ENSUITE INTERESSES AUX LIMITES DE DETECTION ET DE QUANTIFICATION (CV = 10%) DE CHAQUE ANALYTE, TANT D'UN POINT DE VUE THEORIQUE QUE PRATIQUE. FINALEMENT, L'ANALYSE D'ECHANTILLONS DE REFERENCE, APRES MINERALISATION PAR VOIE SECHE OU DIGESTION PAR MICRO-ONDES (SYSTEME OUVERT), VALIDE L'ICP-MS COMME METHODE MULTI-ELEMENTAIRE D'ANALYSE INORGANIQUE DE MATRICES ALIMENTAIRES. L'ETAPE DE PREPARATION DE L'ECHANTILLON RESTE NEANMOINS LE MAILLON FAIBLE DE LA CHAINE ANALYTIQUE ET SERAIT A DEVELOPPER DANS LE FUTUR.